Low-Bat Ack; Screen Saver; Confirm Alarm; Ac Fail Rep - Visonic POWERMAXCOMPLETE - INSTALLER GUIDE Manual

Fully supervised wireless alarm control system
Table of Contents

Advertisement

4.4.31 Low-Bat Ack

(Fig. 4.4, location 31). Here you determine whether the user
will hear or will not hear low battery sound when he tries to
disarm the system with a keyfob whose battery voltage is
low.
Available options are: keyfob L-B on (the user has to
acknowledge the keyfob low battery message) or keyfob
L-B off (the user does not have to acknowledge the keyfob
low battery message).

4.4.32 Screen Saver

(Fig. 4.4, location 32). Here you can determine that if no
key is pressed during more than 30 seconds the display
will read "PowerMax" (to prevent a possible intruder of
knowing the system status). You can determine that
normal display will return after pressing the
followed by entering user code (Refresh by Code/Text by
Code) or after pressing any key (Refresh by Key/Text by
Key). When partition is enabled, you can also determine
that if no key is pressed during more than 30 seconds the
date and time will appear on the display. You can
determine that normal display will return after pressing the
button followed by entering user code (Clock by
Code) or after pressing any key (Clock by Key).
If Refresh by Key/Text by Key is selected, the first
pressing of any key (except Fire and Emergency) will cause
normal display return and the second press will perform the
key function. Regarding the Fire and Emergency keys, the
first key press will cause normal display return and also will
perform the Fire/Emergency function.
Options (Partition Disabled): scrn saver OFF, refresh by
code, refresh by key.
Options (Partition Enabled): scrn saver OFF, text by code,
text by key, clock by code, clock by key.

4.4.33 Confirm Alarm

(Fig. 4.4, location 33). Here you determine that if 2
successive alarms will occur during a specific period, the
second alarm will be considered as a confirmed alarm
(for confirmed alarm reporting, see par. 4.5.12 REPORT
CNF ALARM).
Options: disable 30 min, 45 min, 60 min, or 90 min.

4.4.34 AC FAIL REP

(Fig. 4.4, location 34). Here you determine the time interval
between AC power failure occurrence and the failure
reporting. Options: 5 minutes, 30 minutes, 60 minutes or
180 minutes.

4.4.36 User Permission

(Fig. 4.4, location 36). Here you determine whether the
access to the INSTALLER MODE requires user permission.
If you select ENABLE, the installer mode will be accessible
only through the user menu after entering the user code.
Options: Enable, Disable.
Note: This menu is not available when partition is enabled.
18

4.4.38 Battery Type

(Fig. 4.4, location 38). Here you determine which type of
battery pack is used, so that the system will supply proper
charge current.
Options: 7.2V or 9.6V.

4.4.39 Key Zones Options (Optional)

(Fig. 4.4, location 39). Here you determine whether or not
the system can be armed and disarmed by zones 21-18,
29-30 or 21-30, provided that for these zones "non-alarm
type" and "z-key enable" was predefined (see par. 4.3 and
Appendix E9).
Key zones can be wireless or wired zones.
When using wireless key zones, only the MCT-100 and
MCT-102 transmitters are used. The right pushbutton on
the MCT-102 transmitter or input 2 of the MCT-100
button
transmitter is used for arming in AWAY mode. The left
pushbutton on the MCT-102 transmitter or input 1 of the
MCT-100 transmitter is used for disarming.
When using wired key zones an open circuit arms the
alarm system in AWAY mode and a closed circuit changes
the state of the alarm system from AWAY mode to Disarm.
(For information on how to connect to wired key zones,
see Fig. 3.1C Zones and Sirens Wiring.)
IMPORTANT! Enrolment of the MCT-100 or MCT-102
transmitter must be performed via the right pushbutton on
the MCT-102 transmitter or input 2 of the MCT-100
transmitter (see section 4.3).
Note: Key Zones does not comply with Belgium TO14A
and EN 50131-5-3.
Caution! Arming the system using a transmitter
assigned to zones 21 and 28, or via wired zones 29
and 30 compromises security. This function is,
therefore,
PowerMaxComplete
customer's request.
Options: disable option, z. 21-28 enable, z. 29-30 enable,
or z. 21-30 enable.
only
available
versions
according
in
specific
to
the
D-302754