Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
AUMA Manuals
Controller
SG 10.1
Operation instructions manual
AUMA SG 10.1 Operation Instructions Manual
Quarter-turn actuators
Hide thumbs
1
Table Of Contents
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
page
of
17
Go
/
17
Contents
Table of Contents
Bookmarks
Table of Contents
Table of Contents
1 Equipment Description
2 Transportation
3 Service Conditions
4 Mounting to the Valve/Gearbox
5 Manual Operation
6 Electrical Connections
Terminal Access
Wiring Connections
Completion of Electrical Connection
7 Test Run
Operating Direction for Test Knobs
8 Setting of Limit Switching
Setting the Closed Limit Switch (LSC)
Figure 1 - End Stop Section
Figure 2 - Cover Plate
Figure 3 - Torque Switch
Figure 4 - Mechanical Dial Position Indicator
Setting the Open Limit Switch (LSO)
9 Setting Mechanical Stops
Setting the Closed End Stop
Setting the Open End Stop
10 Setting Torque Switches
11 Setting of Mechanical Dial Position Indicator
12 Single-Phase Motor Speed Adjustment
Exploded-View Parts Illustration
Parts List
13 Optional Equipment
Setting Limit Switch LSA
Setting Limit Switch LSB
Potentiometer Zero Adjustment
Current Transmitter Adjustment
14 Storage
15 Troubleshooting Guide
Advertisement
Quick Links
1
Equipment Description
2
Manual Operation
3
Electrical Connections
4
Wiring Connections
5
Setting of Limit Switching
6
Troubleshooting Guide
Download this manual
See also:
Operating Instructions Manual
OPERATION INSTRUCTONS
MODEL SG 05.1 – SG 12.1
Quarter-Turn Actuators
AUMA Actuators, Inc. USA
100 Southpointe Boulevard • Canonsburg, PA 15317
724-743-2862 • Fax: 724-743-4711
www.auma-usa.com
email: mailbox@auma-usa.com
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the SG 10.1 and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for AUMA SG 10.1
Controller AUMA SG 05.1 Operation Instructions Manual
Control unit: electronic (mwg) with actuator controls aumatic ac 01.1 non-intrusive (80 pages)
Controller AUMA SG 05.1 Operation Instructions Manual
Quarter-turn actuators (17 pages)
Controller AUMA SGR 05.1 Operation Instructions Manual
Part-turn actuators, control unit: electronic mwg with actuator controls aumatic ac 01.2 non-intrusive (80 pages)
Controller AUMA SG 05.1-F05 Operating Instructions Manual
Part-turn actuators sg series; sgr series. with actuators. auma matic am 01.1 (68 pages)
Controller AUMA SG 05.1-F05 Operating Instructions Manual
Part-turn actuators. control unit: electromechanic with actuator controls aumatic ac 01.1 intrusive (80 pages)
Controller AUMA SG 05.1-FA07 Operation Instructions Manual
Electric part-turn actuators. auma norm for flange type fa (32 pages)
Controller AUMA SG Series Operation Instructions Manual
Part-turn actuators with actuator controls mec 03.1 marine version (56 pages)
Controller AUMA SG 03.3 Operation Instructions Manual
Electric part-turn actuators (68 pages)
Controller AUMA NORM Series Operation Instructions Manual
Electric part-turn actuators (28 pages)
Controller AUMA SGExC 05.1 Operation Instructions Manual
Part-turn (80 pages)
Controller AUMA SGExC 05.1 Operation Instructions Manual
Part-turn, control unit: electromechanic with actuator controls (92 pages)
Controller AUMA SG 07.1 Operation Instructions Manual
Quarter-turn actuators (17 pages)
Controller AUMA SGM 04.1 Operation Instructions Manual
Part-turn actuators with integral actuator controls (60 pages)
Controller AUMA SGM Series Operation Instructions Manual
Part-turn actuators with integral actuator controls (48 pages)
Controller AUMA SGM 04.1 Operation Instructions Manual
Part-turn actuators (52 pages)
Controller AUMA SG 03.3 Operation Instructions Manual
Electric part-turn actuators with auma matic (32 pages)
Summarization of Contents
Equipment Description
Transportation
Service Conditions
Mounting to the Valve/Gearbox
Manual Operation
Electrical Connections
Terminal Access
Steps to access the terminal compartment for wiring.
Wiring Connections
Connecting motor and control wires according to the diagram.
Test Run
Operating Direction for Test Knobs
Using test knobs to manually operate limit and torque switches.
Setting of Limit Switching
Setting the Closed Limit Switch (LSC)
Procedure to set the closed limit switch for the actuator.
Setting Mechanical Stops
Setting the Closed End Stop
Adjusting the mechanical stop for the closed position.
Setting the Open End Stop
Adjusting the mechanical stop for the open position.
Setting Torque Switches
Setting of Mechanical Dial Position Indicator
Single-Phase Motor Speed Adjustment
Optional Equipment
Setting Limit Switch LSA
Setting the LSA limit switch for mid-position control signaling.
Setting Limit Switch LSB
Setting the LSB limit switch for mid-position control signaling.
Potentiometer Zero Adjustment
Adjusting the potentiometer to zero in the closed position.
Current Transmitter Adjustment
Adjusting current transmitter zero and maximum values.
Storage
Troubleshooting Guide
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the SG 10.1 and is the answer not in the manual?
Questions and answers