Quick Start Guide
00825-0200-4802, Rev HE
February 2019
Rosemount
3051S Series Pressure
Transmitter and Rosemount 3051SF
Series Flowmeter
®
with WirelessHART
Protocol

Advertisement

loading
Need help?

Need help?

Do you have a question about the Rosemount 300SMV WirelessHART and is the answer not in the manual?

Questions and answers

Summary of Contents for Emerson Rosemount 300SMV WirelessHART

  • Page 1 Quick Start Guide 00825-0200-4802, Rev HE February 2019 ™ Rosemount 3051S Series Pressure Transmitter and Rosemount 3051SF Series Flowmeter ® with WirelessHART Protocol...
  • Page 2 Transmitters. It does not provide instructions for diagnostics, maintenance, service, or troubleshooting. Refer to the Rosemount 3051S and 3051S MultiVariable Wireless Reference Manual for more instruction.This document is also available electronically on Emerson.com/Rosemount. WARNING Explosions could result in death or serious injury.
  • Page 3: Table Of Contents

    February 2019 Quick Start Guide Contents Wireless considerations......... 5 Verify operation........... 21 Mount the transmitter........7 Reference information......... 24 Connect the power module......18 Rosemount 3051S and 3051SMV Wireless Product Certifications........25 Trim the transmitter........19 Close the housing........20 Quick Start Guide...
  • Page 4 Quick Start Guide February 2019 Rosemount 3051S Wireless...
  • Page 5: Wireless Considerations

    Gateway, beginning with the closest device, then working outward from the Gateway. This results in a simpler and faster network installation. Enable Active Advertising on the Gateway to ensure new devices are able to join the ™ network faster. For more information see the Emerson Wireless 1420 Gateway Reference Manual.
  • Page 6 Quick Start Guide February 2019 Figure 1-2: Conduit Entry A. Conduit entry Field Communicator connections The power module needs to be installed before the Field Communicator can interface with the transmitter. This transmitter uses the Black Power Module; Order model number 701PBKKF or part number 00753-9220-0001. Figure 1-3: Connection Diagram CH Input Mode: Dry Contact Only...
  • Page 7: Mount The Transmitter

    February 2019 Quick Start Guide Mount the transmitter Liquid flow applications Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Mount the transmitter so that the drain/vent valves are oriented upward. A.
  • Page 8 Quick Start Guide February 2019 Steam flow applications Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Fill impulse lines with water. A. Direction of flow Rosemount 3051S Wireless...
  • Page 9 February 2019 Quick Start Guide Mounting options Panel mounting Figure 2-1: Coplanar Flange Figure 2-2: Traditional Flange Quick Start Guide...
  • Page 10 Quick Start Guide February 2019 Figure 2-3: In-line Device 3.08 (78) A. U-bolt bracket Pipe mounting Figure 2-4: Coplanar Flange 6.25 (158) Rosemount 3051S Wireless...
  • Page 11 Only use bolts ™ supplied with the transmitter or sold by Emerson as spare parts. Figure 2-7 illustrates common transmitter assemblies with the bolt length required for proper transmitter assembly.
  • Page 12 Table 2-1 . If bolt material is not shown in Table 2-1, contact the local Emerson representative for more information. Use the following bolt installation procedure: Procedure 1. Carbon steel bolts do not require lubrication and the stainless steel bolts are coated with a lubricant to ease installation.
  • Page 13 February 2019 Quick Start Guide 5. Verify the flange bolts are protruding through the sensor module before applying pressure (see Figure 2-8). Example Table 2-1: Torque Values for the Flange and Flange Adapter Bolts Bolt material Head markings Initial torque Final torque Carbon Steel 300 in-lb...
  • Page 14 Quick Start Guide February 2019 O-rings with flange adapters WARNING Failure to install proper flange adapter O-rings may cause process leaks, which can result in death or serious injury. Only use the O-ring that is designed for its specific flange adapter. A.
  • Page 15 February 2019 Quick Start Guide Figure 2-9: Rosemount 702 Transmitter with High Gain, Remote Antenna 2.7.1 Install the high gain, remote antenna (WN option) Prerequisites Find a location where the remote antenna has optimal wireless performance. Ideally this will be 15–25 ft. (4.6–7.6 m) above the ground or 6 ft. (2 m) above obstructions or major infrastructure.
  • Page 16 If the supplied remote mount antenna kit is not installed per these instructions, Emerson is not responsible for wireless performance or non- compliance with spectrum regulations. Procedure 1.
  • Page 17 February 2019 Quick Start Guide Figure 2-10: Applying Coaxial Sealant to Cable Connections 6. Ensure the mounting mast and lightning arrestor are grounded according to local/national electrical code. Any spare lengths of coaxial cable should be placed in 12-in. (0.3 m) coils.
  • Page 18: Connect The Power Module

    Quick Start Guide February 2019 Connect the power module Procedure 1. Remove the housing cover on the field terminal side. 2. Connect the black power module. Rosemount 3051S Wireless...
  • Page 19: Trim The Transmitter

    February 2019 Quick Start Guide Trim the transmitter Transmitters are shipped fully calibrated per request or by the factory default of full scale (span = upper range limit). Zero trim A zero trim is a single-point adjustment used for compensating mounting position and line pressure effects.
  • Page 20: Close The Housing

    Quick Start Guide February 2019 Close the housing Procedure 1. Close the housing cover and tighten to safety specification. 2. Always ensure a proper seal by installing the electronics housing covers so that metal contacts metal, but do not over tighten. Rosemount 3051S Wireless...
  • Page 21: Verify Operation

    February 2019 Quick Start Guide Verify operation There are four methods available to verify operation: • Using the optional local display (LCD) • Using the Field Communicator • Using the Wireless Gateway’s integrated web interface • Using AMS Suite Wireless Configurator If the device was configured with the Network ID and Join Key, and sufficient time has passed, the transmitter will be connected to the network.
  • Page 22 This page will show whether the device has joined the network and if it is communicating properly. Note It may take several minutes for the device to join the network. See Emerson Wireless Gateway Quick Start Guide for more information.
  • Page 23 February 2019 Quick Start Guide Figure 6-2: AMS Wireless Configurator, Device Explorer Screen Troubleshooting If the device is not joined to the network after power up, verify the correct configuration of the network ID and join key, and verify the active advertising has been enabled on the Gateway.
  • Page 24: Reference Information

    Quick Start Guide February 2019 Reference information Figure 7-1: Terminal Diagram P/N 00753-9200-0010 COMM For connecting with a Field Communicator, refer to Figure 1-3. Table 7-1: HART Fast Key Sequence Function Fast Key Menu items sequence Device Info 2, 2, 9 Manufacturer, Model, Final Assembly Number, Universal, Field Device, Software, Hardware, Descriptor, Message, Date, Model Number I, II, III, SI...
  • Page 25: Rosemount 3051S And 3051Smv Wireless Product Certifications

    RF spectrum. Nearly every country requires this type of product certification. Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage.
  • Page 26 Quick Start Guide February 2019 Standards FM Class 3600 – 2011, FM Class 3610 – 2010, FM Class 3611 – ® 2004, FM Class 3810 – 2005, NEMA 250 – 2003 Markings IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; CL III T4; CL 1, Zone 0 AEx ia IIC T4;...
  • Page 27 February 2019 Quick Start Guide Special Conditions for Safe Use (X): 1. The Rosemount 3051S Wireless and Rosemount 3051SMV Wireless enclosure may be made of aluminum alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0 area.
  • Page 28 Quick Start Guide February 2019 Standards GB3836.1-2010, GB3836.4-2010, GB3836.20-2010 Markings Ex ia IIC T4 Ga, T4(–60 70 °C) Special Condition for Safe Use (X): 1. See appropriate certificate. Note Not currently available on the Rosemount 3051S MultiVariable Wireless Transmitter. Japan 8.7.1 I4 TIIS Intrinsically Safe Certificate TC18649, TC18650, TC18657...
  • Page 29 February 2019 Quick Start Guide Special Condition for Safe Use (X): 1. See certificate for special conditions. 8.10 Combinations Combination of I1, I5, and I6 Quick Start Guide...
  • Page 30 Quick Start Guide February 2019 8.11 Rosemount 3051S Wireless Declaration of Conformity EU Declaration of Conformity No: RMD 1099 Rev. I Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount™ 3051S & 300S Wireless Pressure Transmitters, 3051SFx Wireless Flowmeter Transmitters, and 3051SMV &...
  • Page 31 February 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1099 Rev. I EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1:2013 EN 61326-2-3:2013 Radio Equipment Directive (RED) (2014/53/EU) Harmonized Standards: EN 300 328 V2.1.1 EN 301 489-1 V2.2.0 EN 301 489-17 V3.2.0 EN 61010-1: 2010 EN 62311: 2008 PED Directive (2014/68/EU)
  • Page 32 Quick Start Guide February 2019 EU Declaration of Conformity No: RMD 1099 Rev. I ATEX Directive (2014/34/EU) Baseefa13ATEX0127X – Intrinsic Safety Certificate Equipment Group II, Category 1 G Ex ia IIC T4 Ga Harmonized Standards: EN 60079-0:2012+A11:2013 EN 60079-11:2012 PED Notified Body DNV GL Business Assurance Italia S.r.l.
  • Page 33 February 2019 Quick Start Guide 8.12 China RoHS Rosemount 3051S China RoHS List of Rosemount 3051S Parts with China RoHS Concentration above MCVs / Hazardous Substances Hexavalent Polybrominated Polybrominated Part Name Lead Mercury Cadmium Chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr +6) (PBB)
  • Page 34 Quick Start Guide February 2019 Rosemount 3051S Wireless...
  • Page 35 February 2019 Quick Start Guide Quick Start Guide...
  • Page 36 The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.