Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
HT Manuals
Measuring Instruments
I-V500w
User manual
HT I-V500w User Manual
Hide thumbs
1
2
Table Of Contents
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
page
of
80
Go
/
80
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Table of Contents
1 Safety Precautions and Procedures
Preliminary Instructions
During Use
After Use
Overvoltage Categories - Definitions
2 General Description
Introduction
Instrument Features
3 Preparation for Use
Initial Checks
Instrument Power Supply
Storage
4 Description of Parts
Instrument Description
Keyboard Description
Display Description
Initial Screen
5 Main Menu
SET - Instrument Settings
General
Measurement Units
Date/Time
Remote Unit/Solarim
Irradiance
DC Clamp (SOLAR I-Vw or SOLAR I-Ve)
EFF - SETTINGS for TESTING PV SYSTEMS (SOLAR I-Vw or SOLAR I-Ve)
Settings for PV Systems with Single-MPPT Inverter - Single-Phase AC Output
Instrument Settings
PV Plant Parameters
Settings for PV with Single/Multi MPPT Inverter - Single/Three Phase AC Output
Instrument Settings
PV Plant Parameters
MPP300 Status
Selection of the Compensation Relationship of Temperature Effects
DB - Module Database
How to Define a New PV Module
How to Modify a PV Module
How to Delete a PV Module
6 How to Operate
Testing PV Systems (SOLAR I-Vw or SOLAR I-Ve)
Testing of PV Systems with Single-MPPT Inverter - Single-Phase AC Output
Test PV Systems with Single/Multi-MPPT Inverter - Single/Three-Phase AC Output
I-V Curve Measurement
I-V Curve Measurement by Use of Instrument
I-V Curve Measurement by Use of Remote Unit SOLAR-02
I-V Curve Test by Remote Unit SOLAR-02 in RF Connection
I-V Curve Test by Remote Unit SOLAR-02 in Synchro Recording
Meaning of Measurement Results
Quick Check on PV Modules and Strings (IVCK)
General Information
Preliminary Settings
Fast Check IVCK Without Irradiance Measurement
Fast Check IVCK with Irradiance Measurement
Reset Media
List of Display Messages
7 Storing Data
Saving Test Results of PV Checks (SOLAR I-Vw or SOLAR I-Ve)
Saving Test Results of I-V Curve Test
Managing the Results
Recall Data of PV Checks at Display (SOLAR I-Vw or SOLAR I-Ve)
Recall Data of I-V Curve Tests at Display
View Data - Numerical Screens
View Data - Graphic Screens of I-V Curve
View Data - Graphic Screens of Power
Delete Data
8 Connecting the Instrument to a Pc
Connecting by Optical/Usb Cable C2006
Connecting by Wifi
9 Maintenance
General
Battery Replacement
Instrument Cleaning
End of Life
10 Technical Specifications
Yield Test Technical Feratures (SOLAR I-Vw, SOLAR I-Ve)
I-V Test Technical Features (I-V and IVCK)
Safety Specifications
General
General Characteristics
Environment Conditions
Accessories
11 Appendix
Testing Photovoltaic Systems (SOLAR I-Vw, SOLAR I-Ve)
Notes on MPPT (Maximum Power Point Tracker)
Theoretical Aspects of the I-V Curve Measurement
Typical Errors on I-V Curves and Troubleshooting
12 Service
Warranty Conditions
Advertisement
Quick Links
Download this manual
Copyright HT ITALIA 2017
Release EN 2.00 - 24/03/2017
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Table of Contents
Need help?
Do you have a question about the I-V500w and is the answer not in the manual?
Ask a question
Questions and answers
Related Manuals for HT I-V500w
Measuring Instruments HT ISO410 User Manual
400 series (88 pages)
Measuring Instruments HT 400 Series User Manual
(88 pages)
Measuring Instruments HT I-V400w User Manual
(80 pages)
Measuring Instruments HT IRONMETER User Manual
(19 pages)
Measuring Instruments HT IRONMETER User Manual
(124 pages)
Measuring Instruments HT iDM70 User Manual
(24 pages)
Measuring Instruments HT I-V400w-SOLAR I-Vw User Manual
(80 pages)
Measuring Instruments HT I-V600 User Manual
(81 pages)
Measuring Instruments HT HT7 User Manual
(16 pages)
Measuring Instruments HT PVCHECKs-PRO User Manual
(64 pages)
Measuring Instruments HT VEGA74 User Manual
(60 pages)
Measuring Instruments HT PV CHECKs User Manual
(107 pages)
Measuring Instruments HT PQA400 User Manual
Power quality analyzer (124 pages)
Measuring Instruments HT RCDX10 User Manual
(4 pages)
Measuring Instruments HT VEGA78 User Manual
(103 pages)
Measuring Instruments HT HT7051 User Manual
(33 pages)
Summarization of Contents
Safety Precautions and Procedures
Preliminary Instructions
General safety guidelines and precautions for instrument use and installation.
During Use
Recommendations and instructions for safe operation of the instrument.
After Use
Instructions for powering off and storing the instrument after use.
Overvoltage Categories - Definitions
Explanation of measurement categories (CAT IV, CAT III, CAT II, CAT I) for safety.
General Description
Introduction
Overview of the instrument's purpose and capabilities for PV system testing.
Instrument Features
Lists the various tests and functions the instrument can perform.
Preparation for Use
Initial Checks
Steps to perform before using the instrument to check for damage or missing parts.
Instrument Power Supply
Information on the instrument's battery and power management.
Storage
Guidelines for storing the instrument to ensure measurement accuracy.
Description of Parts
Instrument Description
Identifies and describes the physical parts of the instrument's front, upper, and side.
Keyboard Description
Details the function of each key on the instrument's keyboard.
Display Description
Explains the different elements and symbols shown on the instrument's display.
Initial Screen
Describes the information displayed when the instrument is first turned on.
Main Menu
SET – Instrument Settings
Navigates through the instrument settings menu for configuration.
EFF – Settings for Testing PV Systems (SOLAR I-VW or SOLAR I-VE)
Configuration for PV systems, including single/multi-MPPT inverters.
DB – Module Database
Managing the database of PV modules for testing.
How to Operate
Testing PV Systems (SOLAR I-VW or SOLAR I-VE)
General overview of testing PV systems.
I-V Curve Measurement
Detailed procedures for performing I-V curve measurements.
Quick Check on PV Modules and Strings (IVCK)
Instructions for performing quick checks on PV modules and strings.
List of Display Messages
A comprehensive list of error and status messages and their meanings.
Storing Data
Saving Test Results of PV Checks (SOLAR I-VW or SOLAR I-VE)
How to save test results from PV checks.
Saving Test Results of I-V Curve Test
How to save I-V curve test results, including comments and markers.
Managing the Results
Procedures for recalling and managing stored test results.
Connecting the Instrument to a PC
Connecting by Optical/USB Cable C2006
Steps for connecting the instrument to a PC using a USB cable.
Connecting by WiFi
Steps for connecting the instrument to a PC wirelessly via WiFi.
Maintenance
General
General guidelines for maintaining the instrument.
Battery Replacement
Instructions for replacing the instrument's batteries.
Instrument Cleaning
How to clean the instrument properly.
End of Life
Information regarding the disposal of the instrument and its accessories.
Technical Specifications
Yield Test Technical Features (SOLAR I-VW, SOLAR I-VE)
Technical specifications for yield tests.
I-V Test Technical Features (I-V and IVCK)
Technical specifications for I-V and IVCK tests.
Safety Specifications
General safety specifications and standards compliance.
General Characteristics
Overall characteristics including display, memory, RF specs, and power supply.
Environment Conditions
Recommended operating and storage environmental conditions.
Accessories
Lists standard and optional accessories.
Appendix
Testing Photovoltaic Systems (SOLAR I-VW, SOLAR I-VE)
Details temperature effects compensation and PRp calculations for PV systems.
Notes on MPPT (Maximum Power Point Tracker)
Explains the function and importance of Maximum Power Point Tracking.
Theoretical Aspects of the I-V Curve Measurement
Theoretical background and principles of I-V curve testing.
Typical Errors on I-V Curves and Troubleshooting
Common errors encountered during I-V curve tests and their solutions.
Service
Warranty Conditions
Details the warranty terms and conditions for the instrument.
Service
Procedures for contacting service and returning the instrument.
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the I-V500w and is the answer not in the manual?
Questions and answers