Case Temperature Reference Metrology
D.3

Thermal Calibration and Controls

It is recommended that full and routine calibration of temperature measurement
equipment be performed before attempting to perform temperature case
measurement. Intel recommends checking the meter probe set against known
standards. This should be done at 0 ºC (using ice bath or other stable temperature
source) and at an elevated temperature, around 80 ºC (using an appropriate
temperature source).
Wire gauge and length also should be considered as some less expensive
measurement systems are heavily impacted by impedance. There are numerous
resources available throughout the industry to assist with implementation of proper
controls for thermal measurements.
NOTES:
1.
2.
D.4

IHS Groove

Cut a groove in the package IHS; see the drawings given in Figure 7-12 and
Figure 7-13. The groove orientation in Figure 7-12 is toward the IHS notch to allow
the thermocouple wire to be routed under the socket lid. This will protect the
thermocouple from getting damaged or pinched when removing and installing the
heatsink (see Figure 7-37).
Thermal and Mechanical Design Guidelines
It is recommended to follow company standard procedures and wear safety
items like glasses for cutting the IHS and gloves for chemical handling.
Please ask your Intel field sales representative if you need assistance to
groove and/or install a thermocouple according to the reference process.