Safety Instructions
Symbols
Identifies safety symbols used on the probe and documentation.
Precautions
Essential safety precautions to prevent personal injury and equipment damage.
Specifications Overview
Warranted Characteristics
Guaranteed performance characteristics of the current probes.
Nominal Characteristics
Typical performance parameters under standard conditions.
Typical Characteristics
General performance figures and behavioral data.
Environmental Characteristics
Operating and storage conditions like temperature and humidity.
Physical Characteristics
Dimensions and physical properties of the probe heads.
CP030/CP030A Performance Curves
CP030/CP030A Derating Curve
Maximum input current versus frequency for CP030/CP030A.
CP030/CP030A Insertion Impedance
Insertion impedance versus frequency for CP030/CP030A.
CP031/CP031A Performance Curves
CP031/CP031A Derating Curve
Maximum input current versus frequency for CP031/CP031A.
CP031/CP031A Insertion Impedance
Insertion impedance versus frequency for CP031/CP031A.
Probe Operation Guide
Operation Precautions
Safety precautions during probe operation.
Connecting to Test Instrument
Steps for connecting the probe to the oscilloscope.
Connecting to Test Circuit
Procedure for clamping the probe onto a conductor.
Operating with Oscilloscope
Using the probe with the oscilloscope interface.
Probe A/div and Attenuation
Adjusting scale factor and probe attenuation settings.
Bandwidth Limit Setting
How to set and use the bandwidth limit feature.
AC Coupling Function
Using AC coupling to isolate transient signals.
Auto Zero Calibration
Function to calibrate out DC offset.
Degauss Procedure
Procedure to demagnetize the probe core.
Performance Verification Procedure
Test Equipment Required
List of necessary test equipment for verification.
Preliminary Procedure Steps
Initial setup steps before performance verification.
Functional Check
Basic operational check of the probe.
Check LF Accuracy
Procedure to verify low-frequency accuracy.
Performance Verification Test Record
Template for recording verification results.
Care and Maintenance Guidelines
Cleaning Instructions
Instructions for cleaning the probe exterior and cable.
Calibration Interval
Recommended frequency for probe calibration.
Service Strategy
Procedures for handling defective or malfunctioning probes.
Troubleshooting Steps
Steps to diagnose and resolve common operational problems.
Certifications and Compliance
EMC Compliance Details
Compliance with Electromagnetic Compatibility regulations.
Australia & New Zealand EMC Declaration
EMC compliance for Australia and New Zealand regions.
Safety Compliance Directives
Compliance with Low Voltage and Product Safety directives.
Environmental Compliance
Information on WEEE, RoHS, and disposal guidelines.