Summary of Contents for Keysight Technologies M8000 Series

  • Page 2: Warranty

    APPLICABLE LAW, KEYSIGHT DISCLAIMS conditions are fully understood and ware to U.S. government customers under ALL WARRANTIES, EITHER EXPRESS OR its standard commercial license, which is met. IMPLIED WITH REGARD TO THIS MANUAL M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 3: Keysight Cybersecurity

    User documentation includes comprehensive information on features that may impact the secure deployment, use, and decommissioning of our products. This includes details on exposed network ports, the use of cryptography and authentication, and firmware security settings, if necessary. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 4: Safety Summary

    Failure to comply with these precautions or with specific warnings or operating instructions in the product manuals violates safety standards of design, manufacture, and intended use of the instrument. Keysight Technologies assumes no liability for the customer’s failure to comply with these requirements. Product manuals are provided with your instrument on CD-ROM and/or in printed form.
  • Page 5: Safety Symbols

    (Australian Spectrum Management Agency). This indicates compliance with all Australian EMC regulatory information. Indicates that the product was tested and has met the certification requirements for electrical, plumbing and/or mechanical products. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 6 ISM GRP 1-A - This is an Industrial Scientific and Medical (ISM) Group 1 Class A product. This symbol on all primary and secondary packaging indicates compliance to China standard GB 18455-2001. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 7: Compliance And Environmental Information

    (WEEE) is required, as obligated by DIRECTIVE 2012/19/EU and other National legislation. http://about.keysight.com/en/companyinfo/environment/takeback.shtml to understand your Trade in options with Keysight in addition to product takeback instructions. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 8 M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 9: Table Of Contents

    Tips for connecting and removing cables to/from M8053A Interference Source Connecting the adapter to the cable M8053A-801 Mounting the cable with attached adapter to the M8053A front panel M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 10 Use Cable Discharger box to discharge cables Use proper lifting techniques Use proper packaging for transport Check your instrument settings Get more information Get the latest information about your product M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 11: Tools Shipped With M8000 Series Modules

    Tools shipped with M8000 series modules Table 3 lists the tools that are shipped with M8000 series modules. The type of wrench you receive in the kit may vary depending on the module you procure. The sections below specify the type of wrench you require for the connection and removal of the associated cables.
  • Page 12: Preventing Damage To M8050A Connectors Including M8042A/M8043A/M8067A Connectors

    (position 1). The center pin is now retracted from the standard position. Use the 8710-2812 wrench to open the hex nut (position 2) from the female connector of module or device. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 13 Use 8710-1765 wrench to torque / tighten at position 2. Disconnecting the cables Use the 54964-03802 wrench to hold at position 1. Avoid turning inner pin. Use 8710-1765 wrench to loosen at position 2. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 14 . Use the 7 mm side of the 54964-03801 wrench to hold at position 1. Avoid turning inner pin. Use 8710-2812 wrench to loosen at position M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 15: Tips For Connecting And Removing M8042A Connectors (External Semi-Rigid Cable Connection)

    Use the 8710-1765 wrench to torque at position 1. Disconnecting the cables Use the 54964-03801 wrench to hold at position 2. Avoid turning inner pin. Use the 8710-1765 wrench to loosen at position 1. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 16 1-1 & 2-2, along with the 3.5 mm semi-rigid cable, connected at position 3-3, between the M8009A and M8042A modules. All these cables are highly sensitive and must be handled with care. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 17 Tips for Preventing Damage Figure 2 Using semi-rigid cables to connect M8009A and M8042A M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 18 Screw the grooved ring at position 2 by hand only. Tighten the grooved nut again using the 8710-2812 wrench. The center pin will extend into the female connector’s socket to secure the connection. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 19 Remove the cable from the module or device. Avoid repeated bending of cables; a single sharp bend can damage a WARNING cable instantly. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 20: Tips For Connecting And Removing Cables To/From M8053A Interference Source

    2. Removing the cables Use the 7 mm side of the 54964-03801 wrench to hold at position 1. Avoid turning inner pin. Use 8710-1765 wrench to torque at position 2. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 21: Mounting The Cable With Attached Adapter To The M8053A Front Panel

    M8053A module. Use the 7 mm side of the 54964-03801 wrench to hold at position 1. Avoid turning inner pin. Use 8710-2812 wrench to loosen at position 2. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 22: General Tips To Prevent Unnecessary Repairs

    DO NOT Clean and zero the gauge before use Use an out-of-spec connector Use the correct gauge type Use correct end of calibration block Gauge all connectors before first use M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 23: Protect The Input And Output Connectors

    Ensure externally connected items are properly supported (not freely suspended) from the connectors. • Always use torque wrench and gauge tools for connecting RF connectors. • Do not mix 50 Ω and 75 Ω connectors and cables. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 24: Follow Proper Rf Cable And Connector Care

    CONNECTOR BODY - until finger-tight, being careful not to cross the threads. Damage to both connectors will occur if the male center pin is allowed to rotate in the female contact fingers.   M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 25: Using The Torque Wrench

    Follow the torque wrench information listed in the following table: Wrench Information M8042-03801 Wrench 9 mm 54964-03801 Wrench Dual-ended, fits 6 mm and 7 mm 54964-03802 Wrench Dual-ended, fits 8 mm M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 26: Final Connection Using A Torque Wrench

    • Do not damage the earth-grounding protection by using an extension cable, power cable or autotransformer without a protective ground conductor. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 27: Read The Warning Labels And Specifications

    Make sure that there is enough clearance for adequate air-flow. • If the air-flow is restricted, the internal operating temperature will be higher, reducing the instrument’s reliability. • Do not cover the ventilation holes. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 28: Follow Electrostatic Discharge Precautions

    • You should use the cable discharger provided with the initial product shipment and shown in the following figures. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 29 DUT can create AC transients, insufficient grounding, or floating neutral lines which damages the current to flow into or out of the instrument.For more information about electrostatic discharge, contact the Electrostatic Discharge Association www.esda.org. M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 30: Use Proper Lifting Techniques

    Get more information • Consideration for instrument grounding 5989-9200 • Bench instrument site check table 5989-4992 • Do STEP daily ESD self-check 5989-5752 • EOS/ESD limiter N9355CK01 M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 31: Get The Latest Information About Your Product

    M8040A BERT product information: www.keysight.com/find/M8040A • M8050A BERT product information: www.keysight.com/find/M8050A • Check for service and support: www.keysight.com/find/service • Check for updated service notes: www.keysight.com/find/servicenotes • For worldwide service locations information: www.keysight.com/find/assist M8000 Series of BER Test Solutions Tips for Preventing Damage...
  • Page 32 This information is subject to change without notice. © Keysight Technologies 2024 Edition 5.0, September 2024 Printed in Malaysia www.keysight.com...