No.52 /No.53 Present Voltage - FUTABA RS301CR Instruction Manual

Command type servo for robot
Table of Contents

Advertisement

Return Packets
Hdr
ID
Flg Adr Len Cnt Dat
00
FD DF
01
The current temperature is 002DH(45℃), which is identified by the values of No.50 and
No.51 in the return packet.
● No.52/No.53 Present Voltage (2 Byte,Hex Number,Read)
This shows the voltage that is currently used for the servo. Although the meter is
indicated in units of 10mV, there is an approximately ± 0.5V difference between voltage
sensors since each sensor has its own characteristics.
Ex.)To read the current voltage of the servo in ID=1
If you want to get the values of No.52 and No.53 in the servo's memory map as return
packets, send the packets with the bits of 3 to 0 in the "Flags" set to
bit3=1,bit2=0,bit1=0,and bit0=1. After sending, the values for the items between No.42
and No.59 in the memory map will be sent back to you from the servo.
(Please refer to Flags on Page 11 for details.)
If you send only flags, set [COUNT] =1 with [ADRESS] =0 and [LENGTH] =0, and .
nothing should be written in "DATA".
Ex.)To send flags for return packets between No.42 and No.59 in the memory map.
Hdr
ID
Flg Adr Len Cnt Sum
FA AF
01
09
Return Packet
Hdr
ID
Flg Adr Len Cnt Dat
FD DF
01
00
The current voltage is 02E4H (7.4V), which is identified by values of No.52 and No.53 in
the return packet.
12
2A
01
4E FB 00 00 00 00 06 00 2D 00 00 00 00 00 00 00 00 00
Memory Map No. 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
00
00
01
09
2A
12
01
4E FB 00 00 00 00 06 00 2D 00 E4 02 00 00 00 00 00 00
Memory Map No. 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59
29
Sum
A6
Sum
40