No.36 Torque Enable; No.42 /No.43 Present Position - FUTABA RS301CR Instruction Manual

Command type servo for robot
Table of Contents

Advertisement

The setting range is between 0H and 64H.
Ex) Set the maximum torque of servo ID=1 to 80% (50H).
Hdr
ID
Flg Adr Len Cnt Dat Sum
FA AF
01
00
●No.36 Torque Enable(1Byte, Hex Number, Read/Write)
The servo torque can be enabled and disabled. 01H enables the torque and 00H disables
the torque. When the power is turned on, the torque is disabled (00H). When 02H is set, the
servo enters the brake mode and the servo horn can be freely rotated by hand, but a weak
torque is generated.
*When the Torque is changed from disable to enable, the servo holds the present
position.
Ex. 1) Enable servo ID=1 torque.
Hdr
ID Flg Adr Len Cnt Dat Sum
FA AF
01
00
Ex. 2) Disable servo ID=1 torque.
Hdr
ID Flg Adr Len Cnt Dat Sum
FA AF
01
00
Ex. 3) Set servo ID=1 to the brake mode.
Hdr
ID Flg Adr Len Cnt Dat Sum
●No.42 / No.43 Present Position(2Bytes, Hex Number, Read Only)
The present angle of a servo can be read. The angle information
of the present position can be obtained in 0.1 degree units within a
range of -150 degrees in the CCW (counterclockwise rotation)
direction and 150 degrees in the CW (clockwise rotation) direction
with the center of the variation range as 0 degree as shown in the
Fig.
4-2.
Ex.) Read the present position of servo ID=1.
To obtain the value of address Nos. 42 and 43 of the servo as a
return packet, send a "Flag" bit 3=1, bit2=0, bit1=0, bit0=1 send packet. After this packet is
sent, the value of memory map address Nos. 42 to 59 is returned from the servo(See the
Flags item of "Short packet" on p.13 for more information.) Here, The Torque Enable
command and the flag of memory map address Nos. 42 ~ 59 are sent to servo ID=1.
23
01
01
50
24
01
01
01
24
01
01
00
72
24
25
25
-150°
Fig. 4-2
servo range
+150

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs302cd

Table of Contents