If this equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.
C200 and C300 Models Note No. Description Function keys, keypad, or touch display 24V DC power input RS-422 and RS-485 port USB device port RS-232 serial port USB host port Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
You must enter the IP address of your PanelView Component HMI terminal into the address field of your web browser. You can find the IP address on the terminal configuration screen under ‘Communications’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
2. Copy the help files to external media (such as a USB drive or SD memory card). For Component terminal users: Copy the help files to the ‘WebHelp’ folder off the root directory of the USB drive or SD memory card into a folder that is named ‘\WebHelp’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Touch screen 6 in. Color Super Twisted Nematic (STN) 2711C-T6T Color Thin Film Transistor (TFT) 2711C-T10C C1000 Touch screen 10 in. Color STN 2711C-T4T C400 Touch screen and function keys 4 in. Color TFT Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Windows Vista • Windows 7 A USB connection to your PanelView Component HMI terminal is not compatible with the Windows 2000 OS. The PanelView Component Emulator is not compatible with the Windows 2000 OS. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 14
Windows XP SP3 (32 bit only) Windows 7 Internet Explorer 7/8 PVc DesignStation 2.0 Windows Vista — PVc DesignStation 3.0 Windows XP SP3 If you use a browser other than a recommended browser, a warning message appears: Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Use the Configuration Mode Runtime Configuration Runtime Configuration is when changes are made on the actual terminal. Changes can be made whether an application is running or not running. C200 C300 C400, C600, and C1000 Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
C1000 models have the menu that is displayed on the left side of the terminal screen. C200 - Function and Numeric Keys C200 - Function Keys C300 - Function and Numeric Keys C300 - Touch Screen C400, C600, C1000 - Touch C400, C600, C1000 - Touch Screen Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Edit/Test/Run mode) to unload the currently loaded application. If you have not Stop saved changes to the application, you are prompted to do so. Once the application is unloaded, the terminal displays the ‘Configuration’ screen. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
• calibrate the touch screen (if supported). • reset the terminal. • view system information. • change the startup application. • change the terminal language. • change the current date and time. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
1. Click the ‘Terminal Settings’ link. 2. Click the ‘System Information’ tab. 3. Select a language from the ‘Terminal Language’ drop-down list. 4. Click ‘Apply’ or click ‘Cancel’ to restore the current setting. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
100% for brightness and 50% for contrast or adjust the intensity for runtime operations. For C400 (2711C-T4T), C600 (2711C-T6T) and C1000 models, only the brightness can be changed. Follow these steps to change the display brightness and contrast using the ‘PanelView Explorer Startup’ window. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
When you press a key, the display is restored to full brightness. Screen Saver and Dimmer Activates the screen saver and dims the display when the idle timeout elapses. Disable Screen Saver and Dimmer Keeps the display on. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 22
4. Select the idle time of 1, 2, 5, 10, 15, 20, 30, or 60 minimum Follow these steps to configure the screen saver for C200 and C300 models. 1. Select ‘Screen Saver’ on the menu list and press the ‘Enter’ key. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
7. Select ‘Screen Saver Image’ as the file type. 8. Click ‘Next’. 9. Locate where you saved your bitmap file on your computer or external storage device. 10. Select ‘Internal Storage’ as the file destination. 11. Click ‘Transfer’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
5. Drag the slider under ‘Key Repeat Delay’ to set the amount of time that elapses before a character begins to repeat when the key is held down. 6. Click ‘Apply’ or click ‘Cancel’ to restore the current settings. 7. To disable key repeat settings: Deselect ‘Enable key repeat’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Follow these steps to calibrate the touch screen from the terminal. 1. Click ‘Display’ from the menu list. 2. For C400, C600, and C1000 models: Click ‘Calibrate Touchscreen’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Follow these steps to restart the terminal from the ‘PanelView Explorer Startup’ window. 1. Click the ‘Terminal Settings’ link. 2. Click the ‘Display/Input’ tab. 3. Click the ‘Reboot Terminal’ button. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 27
Follow these steps to restart the terminal from C200 and C300 models. 1. Select ‘Reset Terminal’ from the menu list. 2. Press ‘F1’ to reset the terminal. 3. Press ‘F1’ to confirm or ‘F2’ to cancel the reset. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
2. Select the location of the application from the ‘Source’ list as either Internal, USB, or SD (for 2711C-T6C, 2711C-T6M, 2711C-T6T, 2711C-T10C only). 3. Select the name of the startup application from the ‘Name’ list. 4. Click ‘Set As Startup’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 29
6. Press ‘F3’ to go to the list of applications and use the arrows to select the startup application. 7. Use the arrow keys to select ‘Set Startup’. 8. Press ‘F4’ to exit to the main menu. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
1. Go to the ‘Main’ configuration screen. 2. Click the number next to what you want to change under the 'Date and Time' section. A numeric keypad is displayed. 3. Select the values, then click the ‘Enter’ key. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Follow these steps to set a static IP address for the Ethernet port of the connected terminal using the ‘PanelView Explorer Startup’ window. 1. Click the ‘Terminal Settings’ link. 2. Click the ‘Communication’ tab. 3. Deselect the ‘Use DHCP?’ option to manually enter IP addresses. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
As long as security is enabled, any user that tries to access the terminal or the Design-time environment while connected to the terminal must first log in with a valid user name and password. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 33
You can transfer this file to other terminals without having to manually reenter the information. Use the ‘File Transfer’ link on the ‘PanelView Explorer Startup’ window and transfer the ‘Terminal User’ file from internal storage to your computer, USB drive, or SD storage. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
1. Select ‘System Information’ from the menu list, then press ‘Enter’. The system information appears. 2. Press ‘F3’ to see more information, press ‘F2’ to go back, or press ‘F4’ to exit to the main menu. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
(for example, an Ethernet application on a terminal without an Ethernet network connection). Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
9. Click ‘Browse…’ to locate the ‘.cha’ file that you want to import. 10. Select ‘Internal Storage’ as the destination. 11. Click ‘Transfer’. The application is transferred to the internal storage of the terminal. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
They are stored in terminal storage separate from the application and can be accessed from any application on the terminal (or emulator). The names of user-defined objects must begin with an alpha character. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 38
Chapter 2 Use the Configuration Mode Notes: Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
• Verify that power has been removed from the terminal prior to replacing the battery. • Work in a static free environment and wear a properly grounded ESD wristband. • Be careful when touching any of the exposed electronic components to prevent damage from ESD. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 40
6. With the positive polarity facing toward you, insert a new CR2032 lithium battery (such as Cat. No. 2711P-RY2032 or Duracell DL2032). 7. For C400 models: Close the battery cover. For C600 and C1000 models: Reinstall the battery cover. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Ethernet port and a 10/100 Base-T port on an Ethernet hub (without repeaters or fiber) is 100 m (328 ft). In industrial applications, keep the cable length to a minimum. For additional information, see the EtherNet/IP™ Media Planning and Installation Manual, publication ENET-IN001. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
An example with the Cat. No. 1761-CBL-PM02 cable is shown below. 1761-CBL-PM02 Series B Cable 9-pin D-shell 8-pin Min DIN Programming Device Controller 6-pin 9-pin The maximum cable length for serial communication is 15.24 m (50 ft) at 19.2 Kbps Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Device driver on your computer. The USB RNDIS (Remote Network Driver Interface Specification) driver is only supported on Windows® XP and Windows Vista OSs. The USB RNDIS driver is not supported by the Windows 2000 OS. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Install the USB Driver Follow these steps to install the USB driver on your computer. You must be registered with the Rockwell Automation PCDC website and accept the User Agreement before you can download files. 1. Navigate to the Rockwell Automation PCDC site, rok.auto/pcdc.
Page 46
8. If the ‘Windows Logo Test’ warning dialog box is displayed: Click ‘Continue Anyway’. 9. Click ‘Finish’ in the ‘Device Driver Installation Wizard’ dialog box. 10. Click ‘Finish’ in the ‘PanelView USB RNDIS Driver’ dialog box. The drivers are now installed. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
There are two instances of the driver: one for the ‘Boot Loader’ and one for the ‘Windows CE OS’. The USB IP address is always 169.254.254.2. 3. Select ‘Install the software automatically’ then click ‘next’. The wizard searches for the files. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 48
5. Click ‘Finish’ in the ‘Completing the Found New Hardware Wizard’ dialog box for the boot loader. 6. Click ‘Next’ when the ‘Found New Hardware Wizard’ dialog box for the ‘PanelView USB Remote NDIS Network Device’ appears. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 49
8. If the ‘Windows Logo Test’ warning dialog box is displayed, click Continue Anyway. The software installs. 9. Click ‘Finish’ in the ‘Completing the Found New Hardware Wizard’ dialog box for the PanelView USB Remote NDIS Network Device. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 50
If so, cycle power to the terminal and reconnect the USB cable. This dialog box appears. 3. Select the ‘Finish installing software (recommended)’ option to continue installing the boot loader driver. Installation is complete when this dialog box appears. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
4. Compare to the existing firmware version of the terminal to the firmware version of the file to make sure you are performing the desired upgrade. View System Information on page 34 for instructions on how to view the current firmware version. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
6. Download the firmware file to a folder on your computer. 7. Open the file and unpack the contents of the firmware file to the root directory of your USB drive or SD memory card. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Click ‘Clear Private data’. If Microsoft® Internet Explorer® is used: a. Select ‘Tools’ > ‘Internet Options’. b. On the ‘General’ tab, click ‘Delete’ under ‘Temporary Internet Files’ which deletes all temporary internet files, including offline content. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Communication Server Error • Restart the terminal. • Contact technical support providing this data: ID1-/*S:0 Param1*/, ID2-/*S:0 Param2*/, P1-/*S:0 Param3*/, P2-/*S:0 Param4*/, P3-/*S:0 Param5*/, P4-/*S:0 Communication Server Error Param6*/ • Restart the terminal. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 56
Currently loaded application has been 2013 modified. All changes will be lost by running Edit the application and save before performing this operation, otherwise changes to the application may be lost. this application. Continue? Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 57
Enter a value within the allowable range. If you do not know the range, edit the application to determine the 2050 maximum range. allowable range for the device. 2051 Allow Autorun? Press ‘No’ to disallow Autorun. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 58
Data Point= /*S:0 Param2*/ (These are optional OPC defined properties representing data point minimum and maximum values). • The status value could not be converted to the type of the data point assigned Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Determine what changed since the last time the terminal ran normally and decide if the change can be reversed. Check for Adequate Power A terminal that does not receive adequate power could cause unpredictable behavior. Verify the power requirements in the Specifications table. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Application Load and Execute Load N4…N6 POST errors are fatal and most likely due to failed hardware. A fatal error during firmware installation and loading is most likely recoverable by installing the appropriate firmware. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
1. Connect an external USB keyboard to the terminal. 2. Press and hold the ‘Ctrl’ and ‘Shift’ key simultaneously while starting up the terminal. A dialog box appears with the prompt, ‘Return to Out of Box Condition?’. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 62
The terminal restores to the out-of-the-box condition. On the subsequent boot, the file system is formatted and removes the contents including applications, logs, recipes, user-installed fonts, objects, and graphics. Most terminal configuration parameters are returned to their default values. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Russian Customs Union TR CU 020/2011 EMC Technical Regulation Australian Radio Communications Act, compliant with: AS/NZS CISPR 11; Industrial Emissions Korean Registration of Broadcasting and Communications Equipment, compliant with: Article 58-2 of the Radio Waves Act, Clause 3 Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
6. Select ’Font ‘as the file type. 7. Click ‘Next’. 8. Click ‘Browse …’ to locate and select the Font file. 9. Click ‘Open’. 10. Select ‘Internal Storage’ as the destination for the font file. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
‘Flash’, then click ‘Save’ from the emulator main window menu. Font files, especially East Asian Fonts, are large in size and consume significant space on internal storage. Remove all unused fonts from the terminal. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Install’, you have the option of selecting which of these components are installed. Follow these steps to install the PVc Emulator components. You must be registered with the Rockwell Automation PCDC website and accept the User Agreement before you can download files.
Page 68
• Express: only installs the PVc Emulator. Use ‘Express’ install for upgrading the firmware of the emulator. If you selected ‘Custom’ setup: select individual components to install, select install paths (where appropriate), and select install options (where appropriate). Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 69
10. Click ‘Finish’ to complete the installation. The ‘Install Complete’ screen is the final confirmation that the install has been completed successfully after all selected components have completed installation. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
PanelView Component Emulator PanelView Component Extended Support PVc Extended Support is a Rockwell Automation provided accessory for the PVc emulator that consists of extended help files, sample applications, libraries, and font files. These files are originally installed in the ‘Mapped Share’ folder.
2. Select ‘Add or Remove Programs’ and highlight ‘PanelView Component Emulator v1.x’. Multiple versions of the PVc Emulator can reside on the same computer. 3. Click ‘Remove’. 4. Click ‘Yes’ to confirm that you want to remove the PVc Emulator. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
PVc Emulator. Flash - Save Virtual PC Component The directory layout for the Virtual PC is defined by the Microsoft installer for this component. No additional actions are required by the PVc Emulator Installer. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
There is a subdirectory for each terminal type. The subdirectory name is the catalog number for the respective terminal type. These subdirectories contain the files that define each emulated terminal image and behavior. The files that comprise the emulator contain the base name of the terminal catalog. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
The PVc Emulator installer creates entries in the Windows Start Menu that can be used to launch a specific emulated terminal type. There is also a shortcut that is named ‘Applications’ that is simply a shortcut to the mapped ‘Share’ folder. The shortcuts are installed for all users. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
The following is a list of IP addresses to use with your emulator. IP Addresses for Emulators Cat. No. IP Address 2711C-T10C 169.254.253.9 2711C-T6T 169.254.253.10 2711C-T4T 169.254.253.11 2711C-T6M 169.254.253.8 2711C-T6C 169.254.253.7 2711C-T3M 169.254.253.6 2711C-K3M 169.254.253.5 2711C-K2M 169.254.253.4 2711C-F2M 169.254.253.3 Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
0x20009 Base web browser command string not found in <keyname> registry Error constructing web browser command string 0x2000B Failed launching the emulator 0x2000C Emulator failed to start (timeout) 0x2000D Failed launching web browser Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
In PVc DesignStation v2.0, the following features are not yet implemented: • validation • test mode • run mode. PVc DesignStation v2.0 only supports Microsoft® Internet Explorer® 7 and 8. No other internet browsers are currently supported. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
PVc DesignStation can only have one instance running on the computer at any one time. You can download the latest version of the ‘Connected Components Workbench’ software for your Micro800™ programmable controller from the Design and Configuration Software Site. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
2. Run the executable file. The initial splash screen announces that the installer is running. It identifies the product being installed. 3. Click ‘Next’ to continue the installation or ‘Cancel’ to cancel the installation. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 80
The verification screen gives you a chance to cancel the installation process before any permanent changes occur. The progress screen gives you a visual indication of the installation progress. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
3. Highlight ‘PanelView Component DesignStation’/ 4. Click ‘Remove’. 5. Click ‘Yes’ to confirm that you want to remove the software 6. The computer goes through the removal process and shows a progress screen. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Use PVc DesignStation When using PVc DesignStation v2.0 to create or change applications, make sure that your pop-up blocker is off. For more information on working with PVc DesignStation v2.0, refer to the context-sensitive help. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
The firmware update utility always requires a companion firmware image, SC XX-XX.IMG, even if you are only performing a ‘Clean File System or Clean Registry’ operation. Download the utility and the firmware image from the Rockwell Automation PCDC site, rok.auto/pcdc. You must be registered with the Rockwell Automation PCDC website and accept the User Agreement before you can download files.
SC XX-XX.IMG, even if you are only performing a clean file system or clean registry operation. The firmware update utility and the firmware image can be downloaded from the Rockwell Automation PCDC site, rok.auto/pcdc. • a connection from the USB host port of your computer to the USB Allen-Bradley® on the terminal.
The SC XX-XX.IMG image file is typically obtained from the PanelView Component technical support website. When a valid SC XX-XX.IMG image file is opened, the version information is extracted and displayed. 5. Click ‘Begin Waiting for Connect Requests’ to start the firmware update. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 86
‘Update Complete’. The terminal reboots itself when the new image is successfully written to flash memory. IMPORTANT The terminal must remain powered on until the boot cycle is complete. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
The utility is waiting for an update request from the terminal. 6. Restart the terminal. Momentarily open the USB connection at the same time power is cycled. Otherwise, the power from the USB connection may help prevent the terminal from resetting. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
3. Right-click the connection with the name ‘Allen-Bradley PanelView Boot Loader USB Remote RNDIS Network Device’ when it appears. 4. Select ‘Properties’. This connection will disappear after a few seconds). Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 89
5. Click the ‘Advanced’ tab, then click ‘Settings’. 6. Check that the ‘Windows Firewall’ is set to ‘Off’ in the ‘General’ tab. 7. Click ‘OK’. 8. Click the ‘General’ tab for connection properties. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Use the ‘Add or Remove Programs’ tool in the ‘Control Panel’ from the OS of your computer to install a newer version or repair an existing installation of the ‘PanelView Component Firmware Update’ utility. Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
Page 91
PanelView Component HMI Terminals User Manual Rockwell Automation Publication 2711C-UM001J-EN-P - February 2024...
At the end of life, this equipment should be collected separately from any unsorted municipal waste. Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec. Allen-Bradley, Connected Components Workbench, expanding human possibility, Micro800, MicroLogix, PanelView, and Rockwell Automation are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc.