WAGO 752-8303/8000-0002 Manual
WAGO 752-8303/8000-0002 Manual

WAGO 752-8303/8000-0002 Manual

Edge controller
Table of Contents

Advertisement

Quick Links

Manual
WAGO Edge Controller
752-8303/8000-0002
Version 1.3.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 752-8303/8000-0002 and is the answer not in the manual?

Questions and answers

Summary of Contents for WAGO 752-8303/8000-0002

  • Page 1 Manual WAGO Edge Controller 752-8303/8000-0002 Version 1.3.0...
  • Page 2 We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally protected by trademark or patent. WAGO is a registered trademark of WAGO Verwaltungsgesellschaft mbH. Manual Version 1.3.0...
  • Page 3: Table Of Contents

    WAGO Edge Controller Table of Contents 752-8303/8000-0002 Table of Contents Regulations ....................8 Validity of this Documentation..............8 Document portfolio ................. 8 Copyright ....................8 Property rights ..................9 Symbols ....................11 Number Notation .................. 13 Font Conventions ................. 13 Legal Bases ..................
  • Page 4 Table of Contents WAGO Edge Controller 752-8303/8000-0002 4.8.1 Device ....................35 4.8.2 Climatic Environmental Conditions ........... 35 4.8.3 Power Supply ................... 35 4.8.4 Hardware ..................36 4.8.5 Communication ................36 4.8.6 Interfaces ..................36 4.8.7 Connectors ..................37 Approvals ..................... 38 4.10...
  • Page 5 Table of Contents 752-8303/8000-0002 8.4.1 IP Connection via USB ..............55 8.4.2 Changing an IP Address using “WAGO Ethernet Settings” ....55 8.4.3 Temporarily Setting a Fixed IP Address ........... 57 8.4.4 Setting the IP Address via the WBM ..........58 8.4.5...
  • Page 6 Table of Contents WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.1 “PLC Runtime Configuration” Page ......... 93 15.1.1.2.2 “TCP/IP Configuration” Page ..........96 15.1.1.2.3 “Ethernet Configuration” Page..........98 15.1.1.2.4 “Configuration of Host and Domain Name” Page ....101 15.1.1.2.5 “Routing” Page ..............103 15.1.1.2.6...
  • Page 7 WAGO Edge Controller Table of Contents 752-8303/8000-0002 List of Figures ....................167 List of Tables ....................168 Manual Version 1.3.0...
  • Page 8: Regulations

    Regulations WAGO Edge Controller 752-8303/8000-0002 Regulations The WAGO product shall only be installed and operated according to the instructions in this documentation. Always retain this documentation! This documentation is part of the product. Therefore, retain the documentation during the entire service life of the product. Pass on the documentation to any subsequent user.
  • Page 9: Property Rights

    WAGO Edge Controller Regulations 752-8303/8000-0002 Property rights Third-party trademarks are used in this documentation. This section contains the trademarks used. The “®” and “TM” symbols are omitted hereinafter. • Adobe ® and Acrobat ® are registered trademarks of Adobe Systems Inc.
  • Page 10 Regulations WAGO Edge Controller 752-8303/8000-0002 • PROFIBUS is a registered trademark of the PROFIBUS ® Nutzerorganisation e.V. (PNO). • PROFINET is a registered trademark of the PROFIBUS ® Nutzerorganisation e.V. (PNO). • QR Code is a registered trademark of DENSO WAVE INCORPORATED.
  • Page 11: Symbols

    WAGO Edge Controller Regulations 752-8303/8000-0002 Symbols Personal Injury! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury. Personal Injury Caused by Electric Current! Indicates a high-risk, imminently hazardous situation which, if not avoided, will result in death or serious injury.
  • Page 12 Regulations WAGO Edge Controller 752-8303/8000-0002 Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Manual Version 1.3.0...
  • Page 13: Number Notation

    Font Conventions Table 2: Font Conventions Font Type Indicates Names of paths and data files are marked in italic-type. italic e.g.: C:\Program Files\WAGO Software Menu Menu items are marked in bold letters. e.g.: Save > A greater-than sign between two names means the selection of a menu item from a menu.
  • Page 14: Legal Bases

    1.8.1 Subject to Changes WAGO GmbH & Co. KG reserves the right to provide for any alterations or modifications. WAGO GmbH & Co. KG owns all rights arising from the granting of patents or from the legal protection of utility patents. Third-party products are always mentioned without any reference to patent rights.
  • Page 15: Warranty And Liability

    Warranty and Liability The terms set forth in the General Business & Contractual Conditions apply to deliveries and services of WAGO GmbH & Co. KG, and the WAGO Software License Contract applies to software products and products with integrated software. Both are available at www.wago.com. In particular, the warranty is void •...
  • Page 16: Safety Information

    Safety Information WAGO Edge Controller 752-8303/8000-0002 Safety Information Safety Advice (Precautions) This section includes an overall summary of the most important safety requirements and notes that are mentioned in each individual section. To protect your health and prevent damage to devices as well, it is imperative to read and carefully follow the safety guidelines.
  • Page 17 WAGO Edge Controller Safety Information 752-8303/8000-0002 Replace defective or damaged devices! Replace defective or damaged device/module (e.g., in the event of deformed contacts). Protect the components against materials having seeping and insulating properties! The components are not resistant to materials having seeping and insulating properties such as: aerosols, silicones and triglycerides (found in some hand creams).
  • Page 18: Special Use Conditions

    • Do not connect control components and control networks to an open network such as the Internet or an office network. WAGO recommends putting control components and control networks behind a firewall. • In the control components (e.g., for CODESYS) close all ports and services not required by your application to minimize the risk of cyber attacks and to enhance cyber security.
  • Page 19: Overview

    WAGO Edge Controller Overview 752-8303/8000-0002 Overview The controller combines HMI and control functions and can thus replace a PLC controller. Visu software and runtime software both run on the controller. It is suitable for mounting on a DIN rail and stands out on account of its various interfaces.
  • Page 20: Properties

    Properties WAGO Edge Controller 752-8303/8000-0002 Properties View Figure 1: Front view The connectors are located on the front. For details, see section “Properties” > “Connectors.” Figure 2: View on top The operating mode switch with the connector “X8 Lineout”, the settings RESET- STOP-RUN, the “CFG/RST”...
  • Page 21: Labeling

    WAGO Edge Controller Properties 752-8303/8000-0002 Labeling The labeling and the type plate are located on the bottom. The following information about the product is included: Table 3: Labeling Field Example Supply voltage SELV 24V [−25 % … +30 %], LPS...
  • Page 22: Figure 4: Type Plate (Example)

    Properties WAGO Edge Controller 752-8303/8000-0002 Table 4: Type plate Field Example Item Number ITEM-NO.: 0752-8303/8000-0002 Item description 1 Edge Controller Item description 2 EC PIO3 Control number 24703.5303 Date of manufacture (year – month) 2021-02 Release index: Hardware version Power consumption Pmax.=9,4 W...
  • Page 23: Connectors

    WAGO Edge Controller Properties 752-8303/8000-0002 Connectors 4.3.1 Connectors on the front Table 5: Connectors on the front Connector Function X1 und X2 ETHERNET Interface with LED Serial Interface RS-232 or RS-485 CAN Interface POWER. Power supply X6 and X7 USB 2.0 Host Interface...
  • Page 24: X1" And "X2" Ethernet Interfaces

    Properties WAGO Edge Controller 752-8303/8000-0002 4.3.3 “X1” and “X2” ETHERNET Interfaces The ETHERNET interfaces are RJ-45 ports. The orange LED illuminates when there is a LINK and the green one blinks during data transfer. The connectors and cables meet category 5e requirements and guidelines for ETHERNET interfaces.
  • Page 25: Operating As An Rs-232 Interface

    WAGO Edge Controller Properties 752-8303/8000-0002 The connected data cable must be shielded. The cable clamp that is used must guarantee sufficient strain relief and contact between the shield and housing over a large area at the same time. The data direction of the RS 232 interface of the product corresponds to device type DCE.
  • Page 26: X4" - Can Interface

    Properties WAGO Edge Controller 752-8303/8000-0002 To minimize reflection at the end of the line, the RS-485 line must be terminated at both ends by a cable termination. If required, one pull-up or pull-down resistor may be used. These resistors ensure a defined level on the bus when no subscriber is active, i.e., when all subscribers are in “Tri-state”.
  • Page 27: X5" Supply Voltage

    WAGO Edge Controller Properties 752-8303/8000-0002 Table 1: X4 Pin Assignment Assignment CAN-L (CAN data low) GND (reference potential 0 V or ground) CAN-H (CAN data high) Continuous shielding is essential in order to increase the immunity to interference. The metallic housing of the plug is capacitively connected to functional ground.
  • Page 28: X9" - Hdmi Interface Type A

    Properties WAGO Edge Controller 752-8303/8000-0002 The audio output is a three-pole, 3.5 mm stereo socket. Headphones or a compatible audio device can be connected to this socket, e.g. in order to output acoustic warning signals or voice messages that the control application contains.
  • Page 29: Microsd" Memory Card Slot

    </dg_ 4.3.12 “microSD” Memory Card Slot The product is equipped with a laterally mounted slot for microSD and microSDHC memory cards. microSD (max. 2 GB) and microSDHC (max. 32 GB) cards tested by WAGO can be used. Manual Version 1.3.0...
  • Page 30 Use only WAGO memory cards! Proper function and performance cannot be ensured when using SD/SDHC memory cards not approved by WAGO. Pay attention to the memory card preformatting! Please note that memory cards ≤ 2 GB are often formatted with the “FAT16” file system type and can generate up to 512 entries in the root directory.
  • Page 31: Real-Time Clock

    WAGO Edge Controller Properties 752-8303/8000-0002 Real-Time Clock The real-time clock RTC is installed internally and not accessible. It is for internal use only. Deviation/accuracy The deviation is less than ± 4 sec/day with an ambient temperature of 25 °C. Power reserve The clock continues to run min.
  • Page 32: Display Elements

    Properties WAGO Edge Controller 752-8303/8000-0002 Display Elements 4.5.1 Status LED One three-color LED and four two-color LEDs are located on the left side. The meaning of the three-color SYS LED is analogous to that of the status LED on the front.
  • Page 33: Operating Elements

    WAGO Edge Controller Properties 752-8303/8000-0002 Operating Elements You can find the operating mode switch and the “CFG/RST” button on top. 4.6.1 Mode Selector Switch The Mode Selector Switch has the following positions: Table 12: Positions Mode Selector Switch Position Actuation...
  • Page 34: Schematic Diagram

    Properties WAGO Edge Controller 752-8303/8000-0002 Schematic Diagram NOTICE Do not use grounded USB devices! USB interface shielding is not grounded directly, but rather via interference- suppression capacitors. Only keyboards, mice and USB memory sticks should be connected to the USB ports. Do not connect devices that are grounded, e.g., printers, because they bridge the interference-suppression...
  • Page 35: Technical Data

    WAGO Edge Controller Properties 752-8303/8000-0002 Technical Data 4.8.1 Device Table 13: Technical Data ‒ Device Housing material Aluminum, powder-coated Dimensions 65 × 123 × 115 mm (width × height × depth) Type of mounting DIN-rail Weight 835 g IP degree of protection...
  • Page 36: Hardware

    Properties WAGO Edge Controller 752-8303/8000-0002 4.8.4 Hardware Table 16: Technical Data ‒ Hardware Processor ® Cortex ® A9 Quadcore 1.0 GHz External memory extension microSD memory card (max. 2 GB) or („µSD“ Slot) microSDHC memory card (max. 32 GB) Main memory (RAM)
  • Page 37: Connectors

    WAGO Edge Controller Properties 752-8303/8000-0002 4.8.7 Connectors Table 19: Technical Data ‒ Connections Hardware Voltage supply 3 × CAGE CLAMP ® connection cable, max. 3 m to power supply, conductor cross section: 0.14 … 1.5 mm / AWG 25 … 14, strip length: 7 mm / 0.28 inch,...
  • Page 38: Approvals

    Properties WAGO Edge Controller 752-8303/8000-0002 Approvals The following approvals have been granted to the products: Conformity Marking UK Conformity Assessed : UL61010-1, UL61010-2-201 Korea Certification: R-R-W43-EDGE752 Eurasian Conformity: EAC RU Д-DE.PA01.B.09690/21 Detailed information regarding approvals Detailed information regarding approvals can be found at: https://www.wago.com...
  • Page 39: Functions

    WAGO Edge Controller Functions 752-8303/8000-0002 Functions The Controller combines HMI and control functions, since it is a PLC as per IEC 61131-3. Furthermore, four actuators/sensors can be connected to the four digital I/Os. If more are needed, fieldbus nodes can be connected via the fieldbus interfaces.
  • Page 40: Connection Monitoring

    Functions WAGO Edge Controller 752-8303/8000-0002 Connection Monitoring If a CODESYS visualization connection is interrupted, an error message is displayed in the browser. It automatically attempts to restore the connection (reconnect) every 10 seconds. WBM for Configuration/Parameterization The Web-Based Management (WBM) provides an interface for configuring or parameterizing the controller.
  • Page 41 WAGO Edge Controller Functions 752-8303/8000-0002 Change passwords Default passwords are documented in these instructions and therefore do not offer adequate protection! Change the passwords to meet your particular needs. Manual Version 1.3.0...
  • Page 42: Services And Users

    Functions WAGO Edge Controller 752-8303/8000-0002 5.4.2.2 Services and Users All password-protected services and their associated users are listed in the following table. Table 20: Service and Users Users Linux ® Service Web-Based Management (WBM) Linux ® console CODESYS Telnet FTPS SNMP 5.4.2.3...
  • Page 43: Snmp User Group

    ® After launching putty.exe, “login as:” appears. Enter “root” and press [Enter]. You are prompted to enter the password. Enter “wago” as the default password. You are prompted to assign a “New password:”. Enter a unique password that meets the required level of security and press [Enter]. You are prompted to “Retype password:”.
  • Page 44: Web Protocols For Wbm Access

    Functions WAGO Edge Controller 752-8303/8000-0002 5.4.2.6 Web Protocols for WBM Access The HTTP and HTTPS web protocols can be used to access the WBM pages. HTTPS is preferred because it uses the SSL/TLS protocol. The SSL/TLS protocol ensures secure communication through encryption and authentication.
  • Page 45: Default Gateways

    WAGO Edge Controller Functions 752-8303/8000-0002 DHCP response is immediately active and displaces the configured or default host name. If only the configured name should apply, the network administrator must adjust the configuration of the active DHCP server, so that no host name is passed in the DHCP response.
  • Page 46: Restore

    The existing image is deleted. Downloading Software The product has the option to install or update individual software packages. The software packages are available from WAGO. You can install them from your PC via WBM. See also WBM page „Software Uploads“.
  • Page 47: Booting

    WAGO Edge Controller Functions 752-8303/8000-0002 Booting Start Behavior Figure 11: Start Behavior Manual Version 1.3.0...
  • Page 48: Figure 12: Browser Process

    Functions WAGO Edge Controller 752-8303/8000-0002 Browser Figure 12: Browser process Manual Version 1.3.0...
  • Page 49: Licensed Software Components

    WAGO Edge Controller Functions 752-8303/8000-0002 Button “CFG/RST” Pressing the button “CFG/RST” at run-time opens the WBM. Pressing the button at products startup (power ON) prevents the normal auto start and only the WBM starts. The button is not used to make any changes to the settings.
  • Page 50: Mounting

    Mounting WAGO Edge Controller 752-8303/8000-0002 Mounting Avoid electrostatic discharge! The devices are equipped with electronic components that may be destroyed by electrostatic discharge when touched. Please observe the safety precautions against electrostatic discharge per IEC 61340-5-1/-3. When handling the devices, please ensure that environmental factors (personnel, work space and packaging) are properly grounded.
  • Page 51: Mount To The Rail

    WAGO Edge Controller Mounting 752-8303/8000-0002 Mount to the Rail Mount the product by snapping it into the rail according to EN 60715: Place the product with its rail guide on the top edge of the rail. Press the product onto the rail while simultaneously pulling on the latch until it locks into place.
  • Page 52: Connecting

    Connecting WAGO Edge Controller 752-8303/8000-0002 Connecting Earthing Earthing is performed via connector X5. For this, use the included 734-103 Female Connector featuring three CAGE CLAMP connections. First, open CAGE CLAMP no. 3 using an operating tool. ® ® Then insert the conductor (strip length: 7 mm, max. 1.5 mm²) and remove the tool.
  • Page 53: Connecting The Power Supply

    WAGO Edge Controller Connecting 752-8303/8000-0002 If your application includes acoustic signals/warnings, you can plug the 3.5 mm stereo plug of headphones or similar audio systems into the audio output socket. For more information about the interfaces, see section “Device Description” >...
  • Page 54: Commissioning

    Commissioning WAGO Edge Controller 752-8303/8000-0002 Commissioning Switching ON The product does not have an ON/OFF switch and is switched on together with your machine resp. system. After booting the system, you are taken, either automatically or manually, via the HDMI interface to the WBM, “PLC-List”/“Browser Favorites” or a selected controller, depending on the settings (in the menu, accessed by swiping downward from the top edge of the screen).
  • Page 55: Ip Connection Via Usb

    Adapt IP addressing to your specific system structure to ensure that the PC and the controller can communicate with one another using one of the available configuration tools (e.g., WBM or WAGO ETHERNET Settings – see section “Configuration”). Example for incorporating the controller (192.168.2.17) into an existing network: •...
  • Page 56: Figure 13: "Wago Ethernet Settings" - Starting Screen (Example)

    PC. Switch on the power supply to the controller again. Start the “WAGO Ethernet Settings” program. Figure 13: “WAGO Ethernet Settings” – Starting Screen (Example) Click [Read] button to read in and identify the connected controller. Select the “Network” tab: Manual Version 1.3.0...
  • Page 57: Temporarily Setting A Fixed Ip Address

    “WAGO Ethernet Settings” will restart your controller automatically. This action can take about 30 seconds.) You can now close “WAGO Ethernet Settings”, or make other changes directly in the Web-based Management system as required. Click the [Run WBM] button in the right in the pane.
  • Page 58: Setting The Ip Address Via The Wbm

    Commissioning WAGO Edge Controller 752-8303/8000-0002 • Perform a software reset or • Switch off the controller and then switch it back on. 8.4.4 Setting the IP Address via the WBM You can change the IP address of the controller directly via the built-in Web- Based Management without additional tools.
  • Page 59: Initiating Reset Functions

    WAGO Edge Controller Commissioning 752-8303/8000-0002 In conjunction with the DNS server associated with DHCP, the device can be reached using its host name. This consists of a prefix and the MAC address or part of it. The MAC address of the device can be printed on the label on the side of the device.
  • Page 60: Software Reset

    Stored boot projects are deleted, including existing web visualization data. Subsequently installed firmware functions are not overwritten. If you have any questions, contact WAGO Support. The controller is restarted after the factory reset. Proceed as follows to factory reset the controller: Press the Reset button (CFG/RST).
  • Page 61 WAGO Edge Controller Commissioning 752-8303/8000-0002 Do not interrupt the reset process! If you release the Reset button (CFG/RST) too early, then the controller restarts without performing the factory reset. Manual Version 1.3.0...
  • Page 62: Configuring In The Web-Based Management (Wbm)

    Commissioning WAGO Edge Controller 752-8303/8000-0002 Configuring in the Web-Based Management (WBM) The HTML pages (from here on referred to as “pages”) of the Web-Based Management are used to configure the controller. Proceed as follows to access the WBM using a web browser: Connect the controller to the ETHERNET network via the ETHERNET interface X1.
  • Page 63 WAGO Edge Controller Commissioning 752-8303/8000-0002 Depending on the user selected, the navigation bar and the tabs of the  WBM are displayed. If you have disabled cookies in your web browser, you can continue to use the WBM as long as you move directly inside it. However, if you fully reload the website (e.g., with [F5]), you must log in again since the web browser is then not...
  • Page 64: Wbm User Administration

    Commissioning WAGO Edge Controller 752-8303/8000-0002 8.6.1.1 WBM User Administration To allow settings to be made only by a select number of users, limit access to WBM functions through User Administration. Change passwords Default passwords are documented in these instructions and therefore do not offer adequate protection! Change the passwords to meet your particular needs.
  • Page 65: Table 26: Access Rights For Wbm Pages

    Device Status guest Vendor Information Vendor Information guest PLC Runtime PLC Runtime Information guest Legal Information WAGO Licenses WAGO Software License Agreement guest Open Source Open Source Licenses user Licenses WBM Licenses WBM Third Party License Information user WBM Version...
  • Page 66 Commissioning WAGO Edge Controller 752-8303/8000-0002 Table 26: Access Rights for WBM Pages Tab/Navigation WBM Page Title User Connection 2 Configuration admin SNMP General Configuration of general SNMP parameters admin Configuration SNMP v1/v2c Configuration of SNMP v1/v2c parameters admin SNMP v3...
  • Page 67 WAGO Edge Controller Commissioning 752-8303/8000-0002 Table 26: Access Rights for WBM Pages Tab/Navigation WBM Page Title User Diagnostic Diagnostic Information guest Manual Version 1.3.0...
  • Page 68: General Information About The Page

    Commissioning WAGO Edge Controller 752-8303/8000-0002 8.6.1.2 General Information about the Page The IP address of the active device is displayed in the entry line of the browser window. The WBM pages are only displayed after logging in. To log in, enter your username and password in the login window and click the [Login] button.
  • Page 69: Figure 20: Wbm Status Bar (Example)

    WAGO Edge Controller Commissioning 752-8303/8000-0002 Figure 20: WBM Status Bar (Example) • Date and Time - Local date and local time and on the device • Setting of the mode selector switch • LED status of the Device: All LEDs are graphically represented and are labeled with their particular designation (e.g., SYS, RUN, …).
  • Page 70: Reboot Function

    Commissioning WAGO Edge Controller 752-8303/8000-0002 8.6.2 Reboot Function Click the [Reboot] button. To restart, click the [Reboot] button. To cancel the restart, click [Cancel]. Manual Version 1.3.0...
  • Page 71: E!Runtime Runtime Environment

    WAGO Edge Controller e!RUNTIME Runtime Environment 752-8303/8000-0002 e!RUNTIME Runtime Environment General Notes Additional Information Information on the installation and startup of e!COCKPIT is provided in the corresponding manual. Information on programming is provided in the CODESYS 3 documentation. Manual Version 1.3.0...
  • Page 72: Codesys V3 Priorities

    Runtime Environment WAGO Edge Controller 752-8303/8000-0002 CODESYS V3 Priorities A list of priorities implemented for the controller is provided below as supplementary information to the CODESYS 3 documentation. Table 27: CODESYS V3 Priorities Linux ® Scheduler Task Remark Priority...
  • Page 73: Memory Spaces Under E!Runtime

    WAGO Edge Controller e!RUNTIME Runtime Environment 752-8303/8000-0002 Memory Spaces under e!RUNTIME The memory spaces in the controller under e!RUNTIME have the following sizes: • Program memory: 32 Mbytes • Data memory: 128 Mbytes • Input data: 64 kbytes • Output data: 64 kbytes •...
  • Page 74: Diagnostics

    • The network settings are correct. • The controller URL is correct. If the errors cannot be resolved, please contact WAGO Support. support@wago.com Disclose the color that is output. Logbook System messages, e.g., “Start of the controller” or “Communication interruptions”, are logged in the logbook.
  • Page 75: Service

    WAGO Edge Controller Service 752-8303/8000-0002 Service 11.1 Changing the Configuration with the WBM The button “CFG/RST” is on top. The button calls up the Web-Based Management WBM to configure the device. The button must only be pressed using a pointed non-metallic object.
  • Page 76: Firmware Changes

    Therefore, use only documentation appropriate for the target firmware after a firmware change. If you have any questions, feel free to contact our WAGO Support. You can update the firmware in two different ways using: • e!COCKPIT •...
  • Page 77: Use E!Cockpit To Update/Downgrade The Firmware

    WAGO Edge Controller Service 752-8303/8000-0002 11.2.1 Use e!COCKPIT to Update/Downgrade the Firmware Launch e!COCKPIT. Create a new project or open an existing project. Add at least one controller to your e!COCKPIT project either by scanning the network or going to the device catalog and entering the IP address of your controller in the settings dialog.
  • Page 78: Use Wagoupload To Update/Downgrade The Firmware

    Service WAGO Edge Controller 752-8303/8000-0002 11.2.2 Use WAGOupload to Update/Downgrade the Firmware Launch WAGOupload. Click the [Update Firmware] action. In the “Select Target Controllers” dialog, enter the IP address of your controller in the “Transfer via TCP/IP” option. Click [Find Controller].
  • Page 79: Perform Firmware Update/Downgrade

    WAGO Edge Controller Service 752-8303/8000-0002 11.2.3 Perform Firmware Update/Downgrade Proceed as follows if you want to update the controller to a later firmware version or to downgrade the controller to an earlier firmware version: Save your application and the controller settings.
  • Page 80: Removal

    Removal WAGO Edge Controller 752-8303/8000-0002 Removal 12.1 Removal from the Rail To remove, pull down the latch. Use a screwdriver or an operating tool for this. Slide the product out at the lower edge of the rail. Figure 22: Removal from the Din-35 rail Manual Version 1.3.0...
  • Page 81: Disposal

    WAGO Edge Controller Disposal 752-8303/8000-0002 Disposal 13.1 Electrical and electronic equipment Electrical and electronic equipment may not be disposed of with household waste. This also applies to products without this symbol. Electrical and electronic equipment contain materials and substances that can be harmful to the environment and health.
  • Page 82 Disposal WAGO Edge Controller 752-8303/8000-0002 • Observe national and local regulations for the disposal of packaging. • Dispose of packaging of all types that allows a high level of recovery, reuse and recycling. Improper disposal of packaging can be harmful to the environment and wastes valuable resources.
  • Page 83: Accessories

    WAGO Edge Controller Accessories 752-8303/8000-0002 Accessories Several certified accessory items are available for the product. Table 29: Accessories ‒ Memory Cards microSD memory card, 1 GB 758-879/000-002 microSD memory card, 2 GB 758-879/000-3102 Table 30: Accessories ‒ Connecting Cable and connector...
  • Page 84: Appendix

    Appendix WAGO Edge Controller 752-8303/8000-0002 Appendix 15.1 Configuration Dialogs 15.1.1 Web-Based-Management (WBM) 15.1.1.1 “Information” Tab 15.1.1.1.1 “Device Status” Page The “Device Status” page shows information about product identification and the most important network properties. “Device Details” Group This group shows information about product identification.
  • Page 85: Table 32: Wbm "Device Status" Page - "Network Tcp/Ip Details" Group

    WAGO Edge Controller Appendix 752-8303/8000-0002 “Network TCP/IP Details” Group The network and interface properties of the product are displayed in this group. Table 32: WBM “Device Status” Page – “Network TCP/IP Details” Group Parameter Meaning Bridge currently configured; Bridge <n>...
  • Page 86: Vendor Information" Page

    Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.1.2 “Vendor Information” Page You can find the manufacturer and address on the “Vendor Information” page. Manual Version 1.3.0...
  • Page 87: Plc Runtime Information" Page

    WAGO Edge Controller Appendix 752-8303/8000-0002 15.1.1.1.3 “PLC Runtime Information” Page All information about the enabled runtime system and PLC program created in the programming software is provided on the “PLC Runtime Information” page. You will also find a link here to open WebVisu.
  • Page 88: Table 34: Wbm "Plc Runtime Information" Page - "Project Details" Group

    Appendix WAGO Edge Controller 752-8303/8000-0002 “Project Details” Group This group appears if the controller supports the CODESYS V2 runtime system and CODESYS V2 is set as the runtime system. Table 34: WBM “PLC Runtime Information” Page – “Project Details” Group...
  • Page 89: Wago Software License Agreement" Page

    WAGO Edge Controller Appendix 752-8303/8000-0002 15.1.1.1.4 “WAGO Software License Agreement” Page The “WAGO Software License Agreement” page lists the license terms for the WAGO software used in the product. Manual Version 1.3.0...
  • Page 90: Open Source Licenses" Page

    Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.1.5 “Open Source Licenses” Page The license conditions for the open source software used for the product are listed in alphabetical order on the “Open Source Licenses” page. Manual Version 1.3.0...
  • Page 91: Wbm Third Party License Information" Page

    WAGO Edge Controller Appendix 752-8303/8000-0002 15.1.1.1.6 “WBM Third Party License Information” Page On the “WBM Third Party License Information” page, you can find the license text of the open source licenses that apply to the WBM itself. Manual Version 1.3.0...
  • Page 92: Wbm Version" Page

    Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.1.7 “WBM Version” Page On the “WBM Version” page, you can find the version information for the various sections (“Plug-ins”) that the WBM contains. This information may be useful for support if an error is found in the WBM.
  • Page 93: Configuration" Tab

    WAGO Edge Controller Appendix 752-8303/8000-0002 15.1.1.2 “Configuration” Tab 15.1.1.2.1 “PLC Runtime Configuration” Page On the "PLC Runtime Configuration" page, you will find the settings for the boot project created with the programming software and the settings for the web visualization created in the runtime system.
  • Page 94 Appendix WAGO Edge Controller 752-8303/8000-0002 Manual Version 1.3.0...
  • Page 95: Table 37: Wbm "Plc Runtime Configuration" Page - "Webserver Configuration

    WAGO Edge Controller Appendix 752-8303/8000-0002 “Webserver Configuration” Group Table 37: WBM “PLC Runtime Configuration” Page – “Webserver Configuration” Group Parameter Meaning This displays the status (enabled/disabled) of the CODESYS V2 Webserver CODESYS V2 Webserver. State This field only appears if the controller supports the CODESYS V2 runtime system.
  • Page 96: Tcp/Ip Configuration" Page

    Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.2 “TCP/IP Configuration” Page The TCP/IP settings for the ETHERNET interfaces are shown on the “TCP/IP configuration” page. “TCP/IP Configuration” Group The properties are displayed in a separate area for each configured bridge. Table 38: WBM “TCP/IP Configuration” Page – “TCP/IP Configuration” Group...
  • Page 97: Table 39: Wbm "Tcp/Ip Configuration" Page - "Dns Server" Group

    WAGO Edge Controller Appendix 752-8303/8000-0002 “DNS Server” Group Table 39: WBM “TCP/IP Configuration” Page – “DNS Server” Group Parameters Explanation Add additional DNS addresses. New Server IP You can enter 10 addresses. The addresses of the defined DNS servers are Manually Assigned displayed.
  • Page 98: Ethernet Configuration" Page

    Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.3 “Ethernet Configuration” Page The settings for ETHERNET are located on the “Ethernet Configuration” page. “Bridge Configuration” Group Table 40: WBM “Ethernet Configuration” Page – “Bridge Configuration” Group Parameter Meaning Assign the physical ports X1… X <n> to a logical bridge.
  • Page 99: Table 41: Wbm "Ethernet Configuration" Page - "Switch Configuration" Group

    WAGO Edge Controller Appendix 752-8303/8000-0002 “Switch Configuration” Group This group only appears if parameter configuration is supported. Table 41: WBM “Ethernet Configuration” Page – “Switch Configuration” Group Parameters Explanation Enable or disable mirroring of the data traffic between the ports.
  • Page 100: Table 42: Wbm "Ethernet Configuration" Page - "Ethernet Interface

    100 Appendix WAGO Edge Controller 752-8303/8000-0002 “Ethernet Interface Configuration” Group Table 42: WBM “Ethernet Configuration” Page – “Ethernet Interface Configuration” Group Parameter Meaning A separate area is displayed for each interface in Interface X<n> the controller. Enabled You can enable or disable the interface.
  • Page 101: Configuration Of Host And Domain Name" Page

    WAGO Edge Controller Appendix 101 752-8303/8000-0002 15.1.1.2.4 “Configuration of Host and Domain Name” Page The settings for the hostname and domain are displayed on the “Configuration of Host/Domain Name” page. “Hostname” Group Table 43: WBM “Configuration of Host and Domain Name” Page – “Hostname” Group...
  • Page 102 102 Appendix WAGO Edge Controller 752-8303/8000-0002 If only the domain name configured here is to be valid, the configuration of the DHCP server must be adapted so that no domain names are transferred in the DHCP response. Manual Version 1.3.0...
  • Page 103: Routing" Page

    WAGO Edge Controller Appendix 103 752-8303/8000-0002 15.1.1.2.5 “Routing” Page On the “Routing” page you can find settings and information on the routing between the network interfaces. “IP Forwarding through multiple interfaces” Group Table 45: WBM “Routing” Page – “IP Forwarding through multiple interfaces” Group...
  • Page 104: Table 46: Wbm "Routing" Page - "Custom Routes" Group

    104 Appendix WAGO Edge Controller 752-8303/8000-0002 “Custom Routes” Group Each configured static route has its own area in the display. If no static routes have been entered, “(no custom routes)” is displayed. Table 46: WBM “Routing” Page – “Custom Routes“ Group...
  • Page 105 WAGO Edge Controller Appendix 105 752-8303/8000-0002 Manual Version 1.3.0...
  • Page 106: Table 47: Wbm "Routing" Page - "Ip-Masquerading" Group

    106 Appendix WAGO Edge Controller 752-8303/8000-0002 “Dynamic Routes” Group All default gateways received via DHCP are displayed. Default gateways configured via DHCP are given the metric value 10, which means that they are normally used before the statically configured default gateways.
  • Page 107: Table 48: Wbm "Routing" Page - "Port Forwarding" Group

    WAGO Edge Controller Appendix 107 752-8303/8000-0002 “Port-Forwarding” Group Each entry has its own area in the display. Table 48: WBM “Routing” Page – “Port Forwarding” Group Parameters Explanation Specify whether port forwarding should be used. Enabled Disabled Port forwarding is not used.
  • Page 108: Clock Settings" Page

    108 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.6 “Clock Settings” Page The date and time settings are displayed on the “Clock Settings” page. “Timezone and Format” Group Table 49: WBM “Clock Settings” Page – “Timezone and Format” Group Parameter Explanation Select the appropriate time zone for your location.
  • Page 109: Table 51: Wbm "Clock Settings" Page - "Local Time And Date" Group

    WAGO Edge Controller Appendix 109 752-8303/8000-0002 “Local Time and Date” Group Table 51: WBM “Clock Settings” Page – “Local Time and Date” Group Parameter Explanation Local Date Set the date. Local Time Set the local time. Click the [Submit] button to apply a change. The change takes effect immediately.
  • Page 110: Configuration Of Serial Interface Rs232/Rs485" Page

    110 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.7 “Configuration of Serial Interface RS232/RS485” Page The settings for the serial interface are shown on the “Configuration of Serial Interface RS232/485” page. “Serial Interface assigned to” Group The application that the serial interface is currently assigned to is displayed.
  • Page 111: Create Bootable Image" Page

    WAGO Edge Controller Appendix 111 752-8303/8000-0002 15.1.1.2.8 “Create Bootable Image” Page You can create a bootable image on the “Create Bootable Image” page. “Create bootable image from boot device” Group Once the destination has been determined and output, it is then checked and the results of this check are displayed below the settings: Table 53: WBM “Create Bootable Image”...
  • Page 112: Firmware Backup" Page

    112 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.9 “Firmware Backup” Page You can find the controller data backup settings on the “Firmware Backup” page. “Firmware Backup” Group Table 54: WBM “Firmware Backup” Page – “Firmware Backup” Group Parameter Explanation The storage medium from which the device was Boot Device booted is displayed here.
  • Page 113 WAGO Edge Controller Appendix 113 752-8303/8000-0002 Only one package may be copied to the network! If you have specified “Network” as the storage location, only one package may be selected for each storing process. No backup of the memory card! Backup from the memory card to the internal flash memory is not possible.
  • Page 114: Firmware Restore" Page

    114 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.10 “Firmware Restore” Page The settings for restoring the controller data are shown on the “Firmware Restore” page. “Firmware Restore” Group Table 55: WBM “Firmware Restore” Page – “Firmware Restore” Group Parameter Explanation Select the data source for the restore here.
  • Page 115 WAGO Edge Controller Appendix 115 752-8303/8000-0002 Restoration only possible from internal memory! If the device was booted from the memory card, the firmware cannot be restored. Reset by restore A reset is performed when the system or settings are restored by CODESYS!
  • Page 116: Active System" Page

    116 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.11 “Active System” Page The settings for specifying the partition from which the system is started are shown on the “Active System” page. “Boot Device” Group Table 56: WBM “Active System” Page – “Boot Device” Group...
  • Page 117: Mass Storage" Page

    WAGO Edge Controller Appendix 117 752-8303/8000-0002 15.1.1.2.12 “Mass Storage” Page The “Mass Storage” page displays information and settings for the storage media. The group title contains the designation for the storage media (“Memory Card” or “Internal Flash”) and, if this storage medium is also the active partition, the text “Active Partition”.
  • Page 118: Software Uploads" Page

    118 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.13 “Software Uploads” Page On “Software Upload” page, you can install software packages on the product from your PC. Table 60: WBM “Software Uploads” Page – “Upload New Software” Group Parameters Explanation Software file...
  • Page 119: Configuration Of Network Services" Page

    To reduce the risk of cyber attacks and thus increase cyber security, close all ports and services not required by your application in the control components (e.g., port 6626 for WAGO-I/O-CHECK, port 2455 for CODESYS V2 and port 11740 for e!COCKPIT).
  • Page 120: Table 64: Wbm "Configuration Of Network Services" Page - "Http" Group

    In that case, reopen the page. “I/O-CHECK” Group Table 66: WBM “Configuration of Network Services” Page – “I/O-CHECK“ Group Parameters Explanation Service active Enable/disable the WAGO-I/O-CHECK service. Click the [Submit] button to apply a change. The change takes effect immediately. Manual Version 1.3.0...
  • Page 121: Configuration Of Ntp Client" Page

    WAGO Edge Controller Appendix 121 752-8303/8000-0002 15.1.1.2.15 “Configuration of NTP Client” Page The settings for the NTP service are shown on the “Configuration of NTP Client” page. “NTP Client Configuration” Group Table 67: WBM “Configuration of NTP Client” Page – “NTP Client Configuration” Group...
  • Page 122: Plc Runtime Services" Page

    122 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.16 “PLC Runtime Services” Page The settings for various services of the enabled runtime system are displayed on the “PLC Runtime Services” page. “General Configuration” Group Table 68: WBM “PLC Runtime Services” Page – “General Configuration” Group...
  • Page 123: Table 70: Wbm "Plc Runtime Services" Page - "E!Runtime" Group

    WAGO Edge Controller Appendix 123 752-8303/8000-0002 “e!RUNTIME” Group This group only appears if the controller supports the e!RUNTIME runtime system. Table 70: WBM “PLC Runtime Services” Page – “e!RUNTIME” Group Parameter Explanation This displays the status of the e!RUNTIME system e!RUNTIME State (enabled/disabled).
  • Page 124: Ssh Server Settings" Page

    124 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.17 “SSH Server Settings” Page The settings for the SSH service are shown on the “SSH Server Settings” page. “SSH Server” Group Table 71: WBM “SSH Server Settings” Page – “SSH Server” Group Parameters...
  • Page 125: Tftp Server" Page

    WAGO Edge Controller Appendix 125 752-8303/8000-0002 15.1.1.2.18 “TFTP Server” Page The settings for the TFTP service are shown on the “TFTP Server” page. “TFTP Server” Group Table 72: WBM “TFTP Server” Page – “TFTP Server” Group Parameters Explanation Service active Activate or deactivate the TFTP server.
  • Page 126: Dhcp Server Configuration" Page

    126 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.19 “DHCP Server Configuration” Page The “DHCP Server Configuration” page displays the DHCP service settings. “DHCP Server Configuration Bridge <n>” Group Table 73: WBM “DHCP Server Configuration” Page – “DHCP Configuration Bridge <n>” Group...
  • Page 127: Configuration Of Dns Server" Page

    WAGO Edge Controller Appendix 127 752-8303/8000-0002 15.1.1.2.20 “Configuration of DNS Server” Page The “Configuration of DNS Server” page displays the DNS service settings. “DNS Server” Group Table 74: WBM “Configuration of DNS Server” Page – “DNS Server” Group Parameter Explanation Service active You can enable/disable the DNS server service.
  • Page 128: Status Overview" Page

    128 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.21 “Status overview” Page On the “Status overview” page, you can find information about cloud access. “Service” Group Table 75: WBM “Status Overview” Page – “Service” Group Parameter Explanation Version The cloud plug-in version is displayed.
  • Page 129: Configuration Of Connection " Page

    WAGO Edge Controller Appendix 129 752-8303/8000-0002 15.1.1.2.22 “Configuration of Connection <n>” Page You can find settings and information for cloud access on the “Configuration of Connection <n>” page. A page is displayed for each cloud access. “Configuration” Group The parameters indicated depend on the cloud platform setting and, if applicable, on other settings in this group.
  • Page 130 130 Appendix WAGO Edge Controller 752-8303/8000-0002 Table 77: WBM “Configuration of Connection <n>” Page – “Configuration” Group Parameter Explanation Enter the path here to the file encoded in PEM Certification file format that is used for cloud service authentication. Enter the path to the file encoded in PEM format that...
  • Page 131: Table 78: Dependencies Of The Selection And Input Fields For The Selected Cloud

    WAGO Edge Controller Appendix 131 752-8303/8000-0002 Table 77: WBM “Configuration of Connection <n>” Page – “Configuration” Group Parameter Explanation You have the option of creating your own property for the individual MQTT messages to the Azure cloud. This parameter is optional; i.e., if the field is left blank, this property is not sent.
  • Page 132 132 Appendix WAGO Edge Controller 752-8303/8000-0002 Table 78: Dependencies of the Selection and Input Fields for the Selected Cloud Platform Authen Cloud Platform Data Protocol tication Selection or Input Field Password Certification file > Key file > Use websockets Use compression >...
  • Page 133: Configuration Of General Snmp Parameters" Page

    WAGO Edge Controller Appendix 133 752-8303/8000-0002 15.1.1.2.23 “Configuration of General SNMP Parameters” Page The general settings for SNMP are given on the “Configuration of General SNMP Parameters” page. “General SNMP Configuration” Group Table 79: WBM “Configuration of General SNMP Parameters” Page – “General SNMP Configuration”...
  • Page 134: Configuration Of Snmp V1/V2C Parameters" Page

    134 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.24 “Configuration of SNMP v1/v2c Parameters” Page The general settings for SNMP v1/v2c are shown on the “Configuration of SNMP v1/v2c Parameters” page. “SNMP v1/v2c Manager Configuration” Group Table 80: WBM “Configuration of SNMP v1/v2c Parameters” Page – “SNMP v1/v2c Manager Configuration”...
  • Page 135: Table 81: Wbm "Configuration Of Snmp V1/V2C Parameters" Page - "Actually

    WAGO Edge Controller Appendix 135 752-8303/8000-0002 “Actually configured Trap Receivers” Group Table 81: WBM “Configuration of SNMP v1/v2c Parameters” Page – “Actually Configured Trap Receivers” Group Parameters Meaning Each configured trap receiver has its own area in the display. If no trap receiver has been configured, “(no trap receivers configured)”...
  • Page 136: Configuration Of Snmp V3 Users" Page

    136 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.25 “Configuration of SNMP v3 Users” Page The general settings for SNMP v3 are shown on the “Configuration of SNMP v3 Users” page. “Actually configured v3 Users” Group Table 82: WBM “Configuration of SNMP v3” Page – “Actually configured v3 Users” Group...
  • Page 137 WAGO Edge Controller Appendix 137 752-8303/8000-0002 Table 82: WBM “Configuration of SNMP v3” Page – “Actually configured v3 Users” Group Parameters Meaning Specify the authentication type for the SNMP v3 packets. Authentication Type Possible values: - Use no authentication (“None”) - Message Digest 5 (“MD5”)
  • Page 138: Favorites" Page

    138 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.26 “Favorites” Page The “Favorites” page displays the product start page. This page also maintains a list of adjustable controllers for you. For the start page, you can choose a specific controller from the available list that is displayed when the product is powered up.
  • Page 139: Table 83: Wbm "Favorites" Page - "Favorite N" Groups

    WAGO Edge Controller Appendix 139 752-8303/8000-0002 Table 83: WBM “Favorites” Page – “Favorite n” Groups Parameter Meaning Enable/disable this favorite as the start page, which Startpage is displayed when the product is switched on. Enter any name for the controller.
  • Page 140: Autostart" Page

    140 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.2.27 “Autostart” Page You can set the Autostart options on this page. Group “Autostart Delay” Set the countdown displayed when booting before displaying the start page. Within the time set, you have the option to prevent the panel from switching to the start page and to go to the WBM directly.
  • Page 141: Monitoring" Page

    WAGO Edge Controller Appendix 141 752-8303/8000-0002 15.1.1.3 “Monitoring” Page Make settings here for monitoring the product. “Monitoring” Group Table 85: WBM “Browser Settings > Monitoring” Page – “Monitoring” Group Parameter Explanation Specify whether an attempt is made automatically to Reconnect restore a connection if the connection to the product is interrupted.
  • Page 142: Browser Security" Page

    142 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.4 “Browser Security” Page Specify the browser security level. “Browser Security” Group Select the required security level (Low or High). Table 86: WBM “Browser Settings > Browser Security” Page – “Browser Security” Group Parameter Explanation •...
  • Page 143: Fonts" Page

    WAGO Edge Controller Appendix 143 752-8303/8000-0002 15.1.1.5 “Fonts” Page This page allows you to upload or delete fonts from a PC. Click in the “Choose file ...” field. Select the required true-type font file (*.ttf). Click the [Upload] button to upload the font. The uploaded font appears in the list above the “Choose file ...”...
  • Page 144: Display Orientation" Page

    144 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.6 “Display Orientation” Page You can make display orientation settings on the “Display > Display Orientation” page. “Display Orientation” Group Specify whether the display should appear in portrait or landscape mode. The options are landscape, portrait, landscape rotated and portrait rotated.
  • Page 145: Screensaver" Page

    Specify whether an image, the time, a text or a backlight should be displayed or whether screen care should be performed. • Image: The screensaver with the WAGO logo is activated after a time set under “Duration.” • Text: Enter text here that is activated as the screensaver after the time set under “Duration”...
  • Page 146: Wbm User Configuration" Page

    146 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.7.1 “WBM User Configuration” Page The settings for user administration are displayed on the “WBM User Configuration” page. “Change Password” Group Changing Passwords The initial passwords as delivered are documented in this manual and therefore do not provide sufficient protection.
  • Page 147: Fieldbus" Tab

    Parameter Explanation The current status (enabled / disabled) of the State WAGO OPC UA server is displayed. The installed version of the WAGO OPC UA Server Version is displayed here. Any existing OPC UA server license is displayed. License Some features of the WAGO OPC UA server require a paid special license.
  • Page 148: Opc Ua Configuration" Page

    Table 91: WBM “OPC UA Configuration” Page – “General OPC UA Server Configuration” Group Parameter Explanation Service enabled Enable or disable the WAGO OPC UA Server here. Enter the configuration names the controller Ctrl Configuration name contains in the PLC Open Device Set.
  • Page 149: Table 93: Wbm "Opc Ua Configuration" Page - "Opc Ua Endpoints" Group

    WAGO Edge Controller Appendix 149 752-8303/8000-0002 “OPC UA Endpoints” Group Table 93: WBM “OPC UA Configuration” Page – “OPC UA Endpoints” Group Parameter Meaning Enable or disable the OPC UA endpoint “None”. Security Policy - None This allows an unsecured connection to the OPC UA server to be established.
  • Page 150: Table 94: Wbm Page "Opc Ua Configuration" - "Opc Ua Security Settings

    150 Appendix WAGO Edge Controller 752-8303/8000-0002 “OPC UA Security Settings” Group Table 94: WBM Page “OPC UA Configuration” – “OPC UA Security Settings” Group Parameter Explanation The verification is enabled or disabled here. A connection to all clients is Enabled Trust all clients permitted.
  • Page 151: Opc Ua Information Model" Page

    Feature enabled model. Select an XML description file for the information model to be used. The WAGO OPC UA Mapping Editor can be used to create the XML description file. informationmodel.xml Using a specific information model requires an extended OPC UA license! Current information on the currently available OPC UA licenses can be found on the WAGO Web site.
  • Page 152: Modbus Services Configuration" Page

    152 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.8.4 “MODBUS Services Configuration” Page The “Modbus Services Configuration” page displays the settings for various Modbus® services. The groups only appear if the e!RUNTIME system is enabled. Otherwise an information text is displayed. “Modbus TCP Slave” Group Table 96: WBM “Modbus Services Configuration”...
  • Page 153: Bacnet

    WAGO Edge Controller Appendix 153 752-8303/8000-0002 15.1.1.8.5 “BACnet …” Page The WBM pages “BACnet Status”, “BACnet Configuration”, “BACnet Storage Location“, “BACnet Files” and “BACnet Diagnostic” are only fully functional for test purposes or with an installed license. The BACnet functionality can only be used if the controller supports the e!RUNTIME runtime system and e!RUNTIME is used as the runtime system.
  • Page 154: Security" Tab

    154 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.9 “Security” Tab 15.1.1.9.1 “OpenVPN / IPsec Configuration” Page The “OpenVPN / IPsec Configuration” page displays the settings for OpenVPN and IPsec. “OpenVPN” Group Table 98: WBM “OpenVPN / IPsec Configuration” Page – “OpenVPN” Group...
  • Page 155: Table 99: Wbm "Openvpn / Ipsec Configuration" Page - "Ipsec" Group

    WAGO Edge Controller Appendix 155 752-8303/8000-0002 “IPsec” Group Table 99: WBM “OpenVPN / IPsec Configuration” Page – “IPsec” Group Parameter Explanation The current status of the IPsec service is displayed. Current State stopped The service is disabled. running The service is enabled.
  • Page 156: General Firewall Configuration" Page

    156 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.9.2 “General Firewall Configuration” Page The “General Firewall Configuration” page displays the global firewall settings. “Global Firewall Parameter” Group Table 100: WBM “General Firewall Configuration” Page – “Global Firewall Parameter” Group Parameter Explanation Enables/disables the complete functionality of the firewall.
  • Page 157: Interface Configuration" Page

    WAGO Edge Controller Appendix 157 752-8303/8000-0002 15.1.1.9.3 “Interface Configuration” Page The individual interfaces for the firewall settings are displayed on the “Interface Configuration” page. “Firewall Configuration Bridge <n> / VPN” Group A separate group is displayed for each configured bridge.
  • Page 158: Configuration Of Mac Address Filter" Page

    MAC mask: ff:ff:ff:00:00:00 If you enable the default entry, this already allows communication between different WAGO devices in the network. Enable the MAC address filter before activation! Before activating the MAC address filter, you must enter and activate your own MAC address in the “MAC Address Filter Whitelist.”...
  • Page 159: Table 103: Wbm "Configuration Of Mac Address Filter" Page - "Mac Address Filter State Bridge " Group

    WAGO Edge Controller Appendix 159 752-8303/8000-0002 “MAC address filter state Bridge <n>” Group A separate group is displayed for each configured bridge. Table 103: WBM “Configuration of MAC Address Filter” Page – “MAC address filter state Bridge <n>” Group Parameter...
  • Page 160: Configuration Of User Filter" Page

    160 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.9.5 “Configuration of User Filter” Page The “Configuration of User Filter” page displays the settings for custom firewall filters. “User filter” Group Each configured filter has its own area in the display. Table 105: WBM “Configuration of User Filter” Page – “User Filter” Group...
  • Page 161 WAGO Edge Controller Appendix 161 752-8303/8000-0002 Table 105: WBM “Configuration of User Filter” Page – “User Filter” Group Parameters Meaning Enter here the protocols for the new filter. TCP/ The TCP service and UDP service are filtered. Protocol The TCP service is filtered.
  • Page 162: Certificates" Page

    162 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.9.6 “Certificates” Page On the “Certificates” page, you will find options to install or delete certificates and keys. “Installed Certificates” Group Table 106: WBM “Configuration of OpenVPN and IPsec” Page – “Certificate List” Group...
  • Page 163: Security Settings" Page

    WAGO Edge Controller Appendix 163 752-8303/8000-0002 15.1.1.9.7 “Security Settings” Page The network security settings are found on the “Security Settings” page. “TLS Configuration” Group Table 108: “Security Settings” WBM Page – “TLS Configuration” Group Parameters Explanation You can set what TLS versions and cryptographic methods are allowed for HTTPS.
  • Page 164: Advanced Intrusion Detection Environment (Aide)" Page

    164 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.9.8 “Advanced Intrusion Detection Environment (AIDE)” Page The network security settings are available on the “Advanced Intrusion Detection Environment (AIDE)” page. “Run AIDE check at startup” Group Table 109: WBM “Advanced Intrusion Detection Environment (AIDE)” Page – “Run AIDE check at startup”...
  • Page 165 WAGO Edge Controller Appendix 165 752-8303/8000-0002 update is stopped until you call up the “Advanced Intrusion Detection Environment (AIDE)” page again. The messages are displayed below the settings. Manual Version 1.3.0...
  • Page 166: Diagnostic" Tab

    166 Appendix WAGO Edge Controller 752-8303/8000-0002 15.1.1.10 “Diagnostic” Tab 15.1.1.10.1 “Diagnostic Information” Page The settings for displaying diagnostic messages are shown on the “Diagnostic Information” page. Table 111: WBM “Diagnostic Information” Page Parameters Meaning Activate display of only the last n messages. You...
  • Page 167 Password ............43 Figure 11: Start Behavior ...................47 Figure 12: Browser process................48 Figure 13: “WAGO Ethernet Settings” – Starting Screen (Example) ....56 Figure 14: “WAGO Ethernet Settings” – “Network” Tab (Example) .....57 Figure 15: “Open DHCP”, Example Figure ............59 Figure 16: Entering Authentication ..............62 Figure 17: Password Reminder ................64...
  • Page 168 168 List of Tables WAGO Edge Controller 752-8303/8000-0002 List of Tables Table 1: Number Notation ..................13 Table 2: Font Conventions .................13 Table 3: Labeling ....................21 Table 4: Type plate ....................22 Table 5: Connectors on the front ................23 Table 6: Connectors on top ................23 Table 7: Function of RS-232 Signals for DTE/DCE ..........25...
  • Page 169 WAGO Edge Controller List of Tables 169 752-8303/8000-0002 Table 44: WBM “Configuration of Host and Domain Name” Page – “Domain Name” Group ..................101 Table 45: WBM “Routing” Page – “IP Forwarding through multiple interfaces” Group ...................... 103 Table 46: WBM “Routing” Page – “Custom Routes“ Group ......104 Table 47: WBM “Routing”...
  • Page 170 170 List of Tables WAGO Edge Controller 752-8303/8000-0002 Table 81: WBM “Configuration of SNMP v1/v2c Parameters” Page – “Actually Configured Trap Receivers” Group ............135 Table 82: WBM “Configuration of SNMP v3” Page – “Actually configured v3 Users” Group ..................136 Table 83: WBM “Favorites”...
  • Page 171 WAGO Edge Controller List of Tables 171 752-8303/8000-0002 Manual Version 1.3.0...
  • Page 172 WAGO GmbH & Co. KG Postfach 2880 • D - 32385 Minden Hansastraße 27 • D - 32423 Minden Phone: +49 571 887 – 0 Fax: +49 571 887 – 844169 E-Mail: info@wago.com Internet: www.wago.com...