Group 4: Input Function Parameters
4-00
Potentiometer Bias Frequency
Settings
4-01
Potentiometer Bias Polarity
Settings
4-02
Potentiometer Frequency Gain
Settings
4-03
Potentiometer Reverse Motion Enable
Settings
Pr.4-00 to Pr.4-03 are used when the source of frequency command is the analog signal (0 to
+10V DC or 4 to 20 mA DC). Refer to the following examples.
Example 1:
The following is the most common method. Set parameter 2-00 to d1 (0 to +10V signal) or d2 (4 to
20mA current signal).
Example 2:
In this example with the potentiometer set to 0V the Output Frequency is 10 Hz. The mid-point of
the potentiometer becomes 40 Hz. Once the Maximum Output Frequency is reached any further
increase of the potentiometer will not increase output frequency.
Revision August 2006, SE08, SW V2.61
d0.0 to d100.0%
d0
Positive Bias
d1
Negative Bias
d1 to d200%
d0
Forward motion only
d1
Reverse motion enable (must be negative bias)
Chapter 5 Parameters|VFD-S Series
Factory Setting: d0.0
Factory Setting: d0
Factory Setting: d100
Factory Setting: d0
Unit: 0. 1
Unit: 1
5-35