Chapter 5 Parameters|VFD-S Series
Max.
Output
Pr.1-00
Freq.
60Hz
0Hz
0V
4mA
4-04
Multi-function Input Terminal (M0, M1)
Settings
4-05
Multi-function Input Terminal (M2)
4-06
Multi-function Input Terminal (M3)
4-07
Multi-function Input Terminal (M4)
4-08
Multi-function Input Terminal (M5)
Parameters & Functions table:
Value
d0
No Function
d1
M0: FWD / STOP, M1: REV / STOP
d2
M0: RUN / STOP, M1: FWD / REV
3-Wire Operation Control mode (M0,
d3
M1, M2)
d4
External Fault (Normally Open)
d5
External Fault (Normally Closed)
d6
External Reset
d7
Multi-Step Speed Command1
d8
Multi-Step Speed Command2
d9
Multi-Step Speed Command3
d10
Jog operation
Acceleration/Deceleration Speed
d11
Inhibit
First or Second Acceleration or
d12
Deceleration Time Selection
External Base Block (N.O.)
d13
(Normally Open Contact Input)
External Base Block (N.C.)
d14
(Normally Close Contact Input)
5-38
Factory Settings
anti-slope
Pr.1-00=60Hz--Max. output Freq.
Pr.4-00=60Hz--Potentiometer bias freq.
Pr.4-01=1 -- bias polarity
Pr.4-02=100% -- pot. freq. gain
Pr.4-03=1 -- pot. REV. motion enable
10V
20mA
d0 to d29
Function
Value
d15 Up: Increment master frequency
d16 Down: Decrement master frequency
d17 Run PLC Program
d18 Pause PLC Program
d19 Counter Trigger Signal
d20 Counter Reset
Select ACI / Deselect AVI (the priority is
d21
higher than Pr. 2-00 and d26)
d22 PID function disable
d23 JOG FWD
d24 JOG REV
The source of master frequency is AVI. (The
d25
priority is higher than Pr. 2-00 and d26)
The source of master frequency is ACI. (The
d26
priority is higher than Pr. 2-00)
Press UP/DOWN key to switch
d27
forward/reverse (N.O.) motion
Press UP/DOWN key to switch
d28
forward/reverse (N.C.) motion
M0: 0: RUN 1: STOP, M1: no function,
d29
Direction is controlled by keypad
Revision August 2006, SE08, SW V2.61
30
0
60
Hz
10V
0V
20mA
4mA
Potentiometer Scale
Factory Setting: d1
Factory Setting: d6
Factory Setting: d7
Factory Setting: d8
Factory Setting: d9
Function