CAUTIONS
E
LECTROSTATIC DISCHARGE
damage disk drives, add-in boards, and other components. This server can
withstand normal levels of environmental ESD while hot-swapping SCSI
hard disk drives. However, we recommend doing all procedures in this
manual only at an ESD-protected workstation. If one is not available, you
can provide some ESD protection by wearing an antistatic wrist strap
attached to chassis ground of the server—any unpainted metal
surface—when handling components.
H
ANDLING BOARDS AND MODULES
sensitive to ESD and always require careful handling. After removing a
board or module from its protective wrapper or from the server, place it
component-side up on a nonconductive, static-free surface. If you place the
baseboard on a conductive surface, the battery leads can short out. If they
do, this will result in a loss of CMOS data and will drain the battery. Do not
slide a board or module over any surface.
S
ERVER COOLING AND AIRFLOW
removed can damage the server components. For proper cooling and airflow,
always replace the covers before turning on the server.
Equipment Rack Precautions
WARNINGS
A
NCHOR THE EQUIPMENT RACK
to an unmovable support to prevent it from falling over when one or
more servers are extended in front of it on slide assemblies. The anchors
must be able to withstand a force of up to 113 kg (250 lbs.). You must
also consider the weight of any other device installed in the rack.
M
AC
AIN
POWER DISCONNECT
AC power disconnect for the entire rack unit. This main disconnect
must be readily accessible, and it must be labeled as controlling power to
the entire unit, not just to the server(s).
G
ROUNDING THE RACK INSTALLATION
electrical shock hazard, you must include a third wire safety grounding
conductor with the rack installation. If server power cords are plugged
into AC outlets that are part of the rack, then you must provide proper
grounding for the rack itself. If server power cords are plugged into
wall AC outlets, the safety grounding conductor in each power cord
provides proper grounding only for the server. You must provide
additional, proper grounding for the rack and other devices installed
in it.
6
(ESD)
ESD
AND
PROTECTION
: Boards and modules can be extremely
: Operating the server with the covers
: The equipment rack must be anchored
: You are responsible for installing an
: To avoid the potential for an
Intel SC5100 and SC5200 Rack Kit Installation Guide