Intel SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr Installation Manual
Intel SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr Installation Manual

Intel SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr Installation Manual

Rack kit
Hide thumbs Also See for SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr:

Advertisement

Quick Links

Intel
®
SC5100 and SC5200 Rack Kit

Installation Guide

Order Number: A58842-005

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Intel SC5100 - Server Chassis Rack Optimized Hot Swap Redundant Pwr

  • Page 1: Installation Guide

    Intel ® SC5100 and SC5200 Rack Kit Installation Guide Order Number: A58842-005...
  • Page 2 Intel products are not designed, intended or authorized for use in any medical, life saving, or life sustaining applications or for any other application in which the failure of the Intel product could create a situation where personal injury or death may occur. Intel may make changes to specifications and product descriptions at any time, without notice.
  • Page 3: Table Of Contents

    Contents Safety Guidelines Server Precautions ....................... 5 Equipment Rack Precautions ....................6 Rack Installation Procedures Kit Contents.......................... 9 Remove Feet........................10 Remove Top Cover ......................11 Remove 5 ¼-Inch Devices....................12 Remove Door ........................14 Remove Bezel ........................16 Remove EMI Covers ......................17 Remove Side Covers......................
  • Page 4 Installing the Handles ....................30 Removing the Smallest Rail..................30 Attaching the Rail to the Chassis ................31 Rails Installed in a Rack..................... 31 Installing the Server into a Rack ................32 Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 5: Safety Guidelines

    Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server. • Turn off all peripheral devices connected to the server. • Turn off the server using the push-button on/off power switch on the front panel of the server, and unplug the AC power cord from the power supply or wall outlet.
  • Page 6: Equipment Rack Precautions

    AC outlets, the safety grounding conductor in each power cord provides proper grounding only for the server. You must provide additional, proper grounding for the rack and other devices installed in it. Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 7 : The server is designed for an AC line VERCURRENT PROTECTION voltage source with up to 20 amperes of overcurrent protection. If the power system for the equipment rack is installed on a branch circuit with more than 20 amperes of protection, you must provide supplemental protection for the server.
  • Page 8 Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 9: Rack Installation Procedures

    Rack Installation Procedures ® This manual describes the procedure to convert an Intel SC5100 or SC5200 server chassis from the pedestal configuration to the rack configuration. In the following procedures, chassis directions (top, bottom, left, right) refer to a chassis in rack orientation when you are facing the front of the chassis.
  • Page 10: Remove Feet

    3. Remove the four screws that hold the front foot to the chassis and remove the foot. OM12024 Workbench Feet C. Screw * Some chassis details shown may different in your chassis. Figure 1. Removing the Feet Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 11: Remove Top Cover

    Remove Top Cover 1. Loosen the two thumbscrews that attach the top cover to the chassis. 2. Slide the cover backward a short distance, until it stops. 3. Pull the entire cover outward, straight away from the chassis, to disengage the rows of tabs from the notches in the top and bottom edges of the chassis.
  • Page 12: Remove 5 ¼-Inch Devices

    2. Remove and save the two screws that hold the slide rails to the chassis. OM13721 5 ¼-inch device Screw C. Data cable D. Power cable Figure 3. Removing a 5 ¼-Inch Device Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 13: Removing Slide Rails

    3. Remove and save the screws that attach the slide rails to the device. OM12026 Figure 4. Removing Slide Rails Rack Installation Procedures...
  • Page 14: Remove Door

    5. Slide the door to the left to remove it from the other hinge pin. 6. Remove the hinge pins and save for future use. OM13729 Plastic clip Hinge pin Figure 5. Removing the Hinge Pins Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 15: Removing The Hinge Plate

    7. Remove and save the four screws attaching the hinge plate to the chassis. 8. Remove the hinge plate. OM13722 Figure 6. Removing the Hinge Plate Rack Installation Procedures...
  • Page 16: Remove Bezel

    Remove Bezel 1. Press the tab up. 2. Slide the bezel to the right. 3. Remove the bezel from the chassis. OM13724 Figure 7. Removing the Bezel Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 17: Remove Emi Covers

    Remove EMI Covers 1. Remove and save the two screws that attach the EMI covers to the chassis. 2. Remove all of the EMI covers. There will be one thin cover and up to three wider covers. Do not remove any of the hard drive carriers. OM13723 EMI covers Figure 8.
  • Page 18: Remove Side Covers

    3. Remove and save the black clip. 4. Slide the cover backwards and remove it. OM13725 Screw Pull the clip up C. Remove the clip D. Slide the cover off Figure 9. Removing the Right Side Cover Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 19: Remove The Plastic Or Epac System Fan Holder

    Remove the Plastic or Epac System Fan Holder • For the SC5100 Chassis and the SC5200 Base Chassis: Remove the epac holding the system fans. • For the SC5200 HSRP Chassis: 1. Remove the plastic fan holder by removing the 3 retention screws that connect it to the baseplate.
  • Page 20: Install Side Covers

    3. Press the clip down. 4. Insert and tighten the screw you removed earlier. OM13726 Slide the cover on Install the clip C. Push the clip down Figure 10. Installing the Right Side Cover Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 21: Install The Left Side Cover

    Install the Left Side Cover 1. Slide the new cover into position. 2. Insert the black clip. 3. Press the clip down. 4. Insert and tighten the screw you removed earlier. Install the Epac or Plastic Fan Holder • For the SC5100 Chassis and the SC5200 Base Chassis: Re-install the epac holding the system fans.
  • Page 22: Install 5 ¼-Inch Devices Into The Reorientation Bracket

    4. Insert and tighten the four screws removed when you removed the slide rails. OM12029 5 ¼-inch device Screws that hold the device C. EMI shields D. Screws that hold the EMI shields Figure 11. Installing 5 ¼-Inch Devices Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 23: Install The 5 ¼-Inch Reorientation Bracket

    Install the 5 ¼-Inch Reorientation Bracket 1. Slide the bracket into the chassis. 2. Insert and tighten five screws. 3. Connect data and power cables to the devices. OM13720 Screw Data cable C. Power cable Figure 12. Installing the 5 ¼-Inch Reorientation Bracket Rack Installation Procedures...
  • Page 24: Install Bezel

    2. Using a Philips screwdriver, rotate the switch lock ½ turn clockwise. OM13730 Philips screwdriver Chassis intrusion switch lock C. Direction of rotation D. Chassis intrusion switch Figure 13. Installing the Chassis Intrusion Lock Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 25: Moving The Serial Port Cable

    3. If desired, move the serial port cable to the front and remove the serial port filler panel (B). OM13732 Bezel Serial port filler panel C. Rear panel serial port D. Front panel serial port Serial port cable Figure 14. Moving the Serial Port Cable Rack Installation Procedures...
  • Page 26: Installing The Bezel

    4. Position the bezel. Make sure all of the plastic tabs are aligned with their holes. 5. Slide it to the left until the tab locks in place. OM13724 Figure 15. Installing the Bezel Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 27: Install Screw Plate

    Install Screw Plate 1. Position the Screw Plate. 2. Insert and tighten the four screws you removed when you removed the door hinge plate. OM13728 Figure 16. Installing the Screw Plate Rack Installation Procedures...
  • Page 28: Install Front Cover

    2. If you have a hot swap bay installed, remove that plastic cover. 3. Position the bezel by sliding the tabs on the top under the bezel. 4. Tighten the thumbscrews. OM13731 Figure 17. Installing the Front Cover Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 29: Install Top Cover

    Install Top Cover The Rack Kit contains two unpainted top covers. The SC5100 server chassis and the SC5200 Base server chassis use the top cover without a fan access door. The SC5200 HSRP server chassis uses the top cover with a fan access door. 1.
  • Page 30: Install Handles And Rails

    1. Using two screws for each handle, attach the handles to the chassis. OM13733 Handle Screw Figure 19. Installing the Handles 2. Fully extend the rails. 3. Remove the smallest, inner-most rail. OM12541 Figure 20. Removing the Smallest Rail Intel SC5100 and SC5200 Rack Kit Installation Guide...
  • Page 31: Attaching The Rail To The Chassis

    4. Position the rail. 5. Insert and tighten four screws. OM13734 Figure 21. Attaching the Rail to the Chassis 6. Install the outer rail into the rack. a. If your rack has square holes, mount the rail brackets on the inside of the rack pillar. Put the square hook through the desired hole and secure the bracket with an M4 x 8mm screw included with your chassis.
  • Page 32: Installing The Server Into A Rack

    If you encouter resistance while sliding the server into the rack, remove the server from the rack and re-align the rails. OM13736 Figure 23. Installing the Server into a Rack 11. Secure the server to the rack. See your rack documentation for more information. Intel SC5100 and SC5200 Rack Kit Installation Guide...

This manual is also suitable for:

Sc2100Sc5200

Table of Contents