Severe or fatal injuries WARNING Possible dangerous situation Minor injuries CAUTION NOTICE Possible damage to property Damage to the product or its envi- ronment INFORMATION Useful information or tip: Simplifies handling of the product. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Read the documentation before you start working with the product. Product names and trademarks The product names mentioned in this documentation are trademarks or registered trademarks of the respective titleholders. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Ensure that systems in which the product is installed are equipped with additional monitoring and protection devices. Observe the applicable safety regulations and leg- islation governing technical work equipment and accident prevention regulations. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
These instructions must enable the persons to carry out the required activities and work steps safely and in accordance with regulations. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
• Operation in a mining facility or outdoors • Operation in potentially explosive atmospheres and high fire risk areas • Use in areas with a strong magnetic field • Use in direct sunlight Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Use only spare parts and accessories manufactured according to the specifications of SEW‑EURODRIVE. SEW‑EURODRIVE is not liable for modifications, changes, addi- tions and / or alterations to the product. Clean the screen with a commercial glass cleaner and a dry and clean cloth. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Glass front Card slot for a microSD memory card Galvanized sheet metal Mounting element with screw Gasket Ethernet interface (→ 2 47) 2 USB interfaces (→ 2 47) DC 24 V voltage supply (→ 2 47) [10] Grounding strip [11] Basic module Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Glass front Card slot for a microSD memory card Galvanized sheet metal Mounting element with screw Gasket Ethernet interface (→ 2 47) 2 USB interfaces (→ 2 47) DC 24 V voltage supply (→ 2 47) [10] Grounding strip [11] Basic module Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
The following figure shows the front and rear of the device: 33967307531 Front Rear Screen Glass front Mounting element with screw Gasket Connections (→ 2 33) Control panel for screen display PE screw Basic module Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
The microSD memory card slot integrated in the basic module allows for using SD memory cards up to 2 GB and SDHC memory cards up to 32 GB. 35158921995 MicroSD memory card INFORMATION: Insert the microSD memory card with the contacts facing to the rear of the device. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
The design of the USB interfaces depends on the device design used. Web operator panels WOP11D-70-0 and WOP11D-100-0 The operator panel has 2 USB interfaces 2.0. Web operator panels WOP11D-150-0 and IPC11D-150-0 The operator panel has 2 USB interfaces 2.0, and 1 USB interface 3.0. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
If you are not sure which accessories you need, employees at SEW‑EURODRIVE will be happy to help you make the right selection. Accessories Part number Switched-mode power supply with 2.5 A 01881817 1) Only applies to web operator panels WOP11D-70-0 and WOP11D-100-0. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Do not apply force when tightening the screw. Adhere to the recommended torque to fasten the screws. • Be careful when using the display to avoid damage and scratches. INFORMATION Adhere to the "safety notes" (→ 2 9) during installation. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Replace the battery with a BR 2032 battery. Use of another type of battery may present a risk of fire or explosion. Flat surface For use on a flat surface of a type 4X enclosure indoor use only. Power terminals Use minimum 75 °C copper wire only. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
The information on the nameplate of the device corresponds to the line voltage. • The device is undamaged (no damage caused by transport or storage). • The ambient temperature corresponds to the specification in the operating instruc- tions and the nameplate of the device. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
The following figures show the space required for installing the device. 4.4.1 Web operator panels WOP11D-70-0 and WOP11D-100-0 9007233218373131 All dimensions are specified in mm. 4.4.2 Web operator panel WOP11D-150-0, IPC11D-150-0 33882503307 All dimensions are specified in mm. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
They may cause short circuits and damage the batteries or circuits of the device. Proceed as follows when unpacking the device: 1. Unpack the delivery and check it for completeness. 2. Inform your supplier immediately in the event of damage. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
3. Insert the mounting element into the intended T slot at the backside of the operator panel. 4. Move the mounting element sideways so that it locks. 33963706123 Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 26
6. Repeat these steps, beginning with the mounting element diagonally across from the already fastened element. Then fasten the remaining mounting elements in the same manner. 35158917131 ð The operator panel has been installed. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
2. Place the operator panel from the front into the cut-out of the mounting plate and push it carefully up to the stop. 3. Rotate the mounting elements at the backside of the operator panel so that the screws are positioned above the mounting plate. 33969355403 Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 28
5. Repeat these steps, beginning with the mounting element diagonally across from the already fastened element. Then fasten the remaining mounting elements in the same manner. 35158805003 ð The operator panel has been installed. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
3. Place the operator panel from the front into the cut-out of the mounting plate and push it carefully up to the stop. 4. Place the mounting element with the screw into the housing of the operator panel. 33869329419 Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 30
5. Tighten the screw clockwise with a tightening torque of 0.8 Nm (± 0.2 Nm) until the mounting element is pressed against the housing wall. 33869333387 6. Repeat the procedure for the remaining screws. 33869337355 ð The operator panel is now mounted. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Always touch the connector when plugging or unplugging a cable. INFORMATION To remove the protective film, pull the protective film off the front of the device to the side. INFORMATION Adhere to the "safety notes" (→ 2 9) during installation. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Web operator panel WOP11D-70-0 35158919563 Web operator panel WOP11D-100-0 35158807435 X3: Card slot for microSD memory cards up to 2 GB, and SDHC memory cards up to 32 GB. Grounding strip for optional device grounding (→ 2 34). Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Ethernet interface LAN 1, 1 × 10/100/1000 Mbit, shielded RJ45 (→ 2 48) IP address: 192.168.1.99 USB interface, 1 × USB host 3.0 type A (→ 2 48) USB interface, 2 × USB host 2.0 type A (→ 2 48) X3: Connection for DC 24 V voltage supply (→ 2 48) X2: Not assigned [10] X1: Not assigned Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
(e.g. 10 mm). 5.3.2 Web operator panel WOP11D-150-0, IPC11D-150-0 Connect the grounding cable to the grounding screw of the device. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Ensure correct polarity when connecting the voltage supply. INFORMATION Operate the device only with a SELV voltage source (Safety Extra Low Voltage) that meets the requirements of an LPS (Limited Power Source) according to DIN EN 60950‑1. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Reference potential DC 24 V voltage supply (±20%) 5.4.2 Web operator panel WOP11D-150-0, IPC11D-150-0 The following figure shows the connection of the voltage supply: 33872158859 Terminal Signal Description socket Reference potential Functional earth DC 24 V voltage supply Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
ð Terminal socket X3 of the WOP11D-150-0, IPC11D-150-0 operator panel 4. Connect a power supply cable to the power socket that meets regional require- ments. ð The voltage supply is connected. ð The operator panel starts automatically. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
URL, display, FTP, IP tables, screensaver, web browser settings, passwords, diagnostics, and others. For a detailed description of the setting options and functions, refer to the software manual for WOP11D-70-0, WOP11D-100-0, WOP11D-150-0 web operator panels. 6.2.2 HTML5 browser The Toolkit software package includes an HTML5 browser based on chromium.
Control panel of IPC11D-150-0 INFORMATION The control panel is only available for WOP11D-150-0 and IPC11D-150-0 operator panels. The control panel is located on the underside of the base module, see chapter "Web operator panel WOP11D-150-0, IPC11D-150-0" (→ 2 15). Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 40
"Power" The device is switched off. Is lit green The device is switched on. Flashes green The device is in standby mode. "DriveActivity" No activity Flashing Memory access Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
This product and its accessories may fall within the scope of the country-specific appli- cation of the WEEE Directive. Dispose of the product and its accessories according to the national regulations of your country. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Waste disposal according to the Battery Directive 2006/66/EC This product contains batteries or accumulators. Dispose of this product and the bat- teries or accumulators separately from the municipal waste according to the national regulations. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Before cleaning, switch off the operator panel because the screen display is safe to touch. To remove dust and dirt particles, clean the surface of the screen with a commercial glass cleaner and a dry and clean cloth. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
10.5 Power supply cable Power supply cable Connector type Phoenix MSTBA 2.5/3-G 24 V supply connector Phoenix FKCN 2.5/3-ST Cable length Max. 3 m, unshielded Min. 0.5 mm Cable cross section Max. 1.5 mm Stripping length 10 mm Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
EN 61000-6-2 (interference immunity) (interference immunity) device EN 61000-6-4 (emission) EN 55032 (emission) 2011/65/EU 2015/863/EU RoHS-II Directives 2011/65/EU 2017/2102/EU Directive on the EN 62368-1 safety of information technology devices UL approval NRTL (cTÜVus) UL 62368-1 UL 62368-1 CE certification Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
X1: DC 24 V voltage supply Terminal socket, 3-pin Signal X5: Ethernet interface RJ45 socket Signal TX0+ TX0- TX1+ TX2+ TX2- TX1- TX3+ TX3- X9: USB interface 2.0 (type A) USB socket Signal USB_VCC USB_D- USB_D+ Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Signal TX0+ TX0- TX1+ TX2+ TX2- TX1- TX3+ TX3- USB interface 2.0 (type A) USB socket Signal +USB_VCC USB_D- USB_D+ USB interface 3.0 (type A) USB socket Signal +USB_VCC USB_D- USB_D+ USB_RX- USB_RX+ USB_TX- USB_TX+ Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
All dimensions are specified in mm. Width Height Installation Thickness of mounting depth plate 189.7 mm 121.5 mm Approx. 42.5 mm 3 – 7 mm 10.10.2 Web operator panel WOP11D-100-0 Device 35.4 32.7 13.3 13.3 264.5 163.5 250.5 35158802571 All dimensions are specified in mm. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 52
Technical data Dimension drawings Cut-out for installation 34103585675 All dimensions are specified in mm. Width Height Installation Thickness of mounting depth plate 252 mm 174.5 mm Approx. 35.5 mm 3 – 7 mm Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Technical data Dimension drawings 10.10.3 Web operator panel WOP11D-150-0, IPC11D-150-0 Device 69.1 67.85 29.5 29.5 34103561867 All dimensions are specified in mm. Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Page 54
Technical data Dimension drawings Cut-out for installation 33883737355 All dimensions are specified in mm. Width Height Installation Thickness of mounting depth plate 389 mm 250 mm Approx. 70 mm 3 – 7 mm Operating Instructions – WOP11D-70-0, WOP11D-100-0, WOP11D-150-0, IPC11D-150-0...
Need help?
Do you have a question about the WOP11D-70-0 and is the answer not in the manual?
Questions and answers