CONTENTS TECHNICAL SPECIFICATION OF PRODUCT ....................5 FUNCTION DESCRIPTION ........................5 ADVICE FOR CUSTOMERS ........................6 1.2.1 HOT WATER CONSUMPTION ..................... 6 1.2.2 ENERGY SAVING ......................... 6 1.2.3 EMERGENCY POWER CONSUMPTION ..................6 DESIGN AND GENERAL HEATER DIMENSIONS ................... 8 1.3.1 DESCRIPTION OF BASIC PARTS OF THE HEATER ................
Page 3
CONTROLS DESCRIPTION ......................... 22 3.6.1 MODE CHANGE WITH CONTROLLER ..................22 3.6.2 BASIC DISPLAY ......................... 22 3.6.3 TEMPERATURE SETTING ......................22 3.6.4 TIME SETTING .......................... 22 3.6.5 FAILURE STATE ......................... 23 SOFTWARE FOR MOBILE DEVICES ......................24 4.1.1 BASIC DESIGN .......................... 24 4.1.2 PAIRING SCREEN ........................
Page 4
CAREFULLY READ THIS MANUAL BEFORE INSTALLING THE WATER HEATER! Dear Customer, Družstevní závody Dražice - strojírna s.r.o., would like to thank you for your decision to use a product of our brand. With this guide, we will introduce you to the use, construction, maintenance and other information on electrical water heaters.
1 TECHNICAL SPECIFICATION OF PRODUCT FUNCTION DESCRIPTION The heater is designed for accumulation hot water using electricity. Water is heated by an electric element in an enameled thermally insulated tank. The unit is controlled by means of the control unit during heating period.
ADVICE FOR CUSTOMERS 1.2.1 HOT WATER CONSUMPTION Consumption of hot water in households depends on the number of people, amount of sanitary equipment, length, diameter and insulation of piping in the flat, or on individual habits of users. The cheapest option of water heating comes at the time when the electricity rate is reduced. Find out in what time intervals your electricity supplier provides reduced tariff and, depending on that information, select relevant volume and power input of the heater so that your hot water consumption covered the needs of your household.
Page 7
OKHE 100 - OKHE 125 - OKHE 160 - SMART SMART SMART VOLUME MAX OPERATING OVERPRESSURE IN THE TANK ELECTRICAL CONNECTION 1/N/PE ~ 230V/50 Hz RECOMMENDED BREAKER 16 A INPUT 2200 EL. PROTECTION IP44 MAX TEMPERATURE TV °C RECOMMENDED HOT WATER (HW) °C TEMPERATURE MAX WEIGHT OF THE HEATER...
DESIGN AND GENERAL HEATER DIMENSIONS The heater tanks are made of a steel plate and tested by 1.5 multiple of operation pressure value. The inside of the tank is enameled. A flange is welded onto the bottom of the tank with a flange lid screwed to it. A sealing ring is inserted between the flange lid and the flange.
2 OPERATION AND FITTING INSTRUCTIONS OPERATING CONDITIONS The tank shall only be used in accordance with the conditions specified on the power plate and in instructions for electric wiring. Besides legally acknowledged national regulations and standards, also conditions for connection defined in local electric and water works have to be adhered to, as well as the installation and operation manual.
If the hot water heater is mounted in a tight, small space, or in an intermediate ceiling, etc., you have to make sure that the connecting side of the appliance (connections to water supply, area for electric plugging) remained accessible and no heat accumulation occurs. Free space of up to 600 mm from the bottom edge of the heater has to be available under the heater.
Heaters must be provided with a discharge valve mounted on the cold service water inlet to the heater for potential disassembly or repair. When assembling the security equipment, follow the standard. Figure 4 ELECTRIC WIRING 2.4.1 ELECTRIC INSTALLATION GENERAL INFORMATION Do not plug the water heater in HDO socket;...
If the supply cord is damaged, it must be replaced by a company (person) authorized to such activity in order to avoid a hazard. 2.4.2 ELECTRONIC THERMOSTAT CONNECTION DIAGRAM ANODE HEATING UNIT Figure 5 The terminals of L, N, PE (230V/50Hz) supply include factory connected flexible plug with length 2.5m connectable to the standardized plug EU.
FIRST HEATER COMMISSIONING Before opening the power supply, the tank must be filled with water. The process of first heating must be executed by licensed professional who has to check it. Both the hot water outlet pipe and safety armature parts may be hot. During the heating process the pressurized connection water that increases its volume due to heating must drip off the safety valve.
Drainage of service water shall be performed after closing the shut-off valve in the cold water supply piping (through the discharge valve for safety valve combination), and with simultaneous opening of all hot water valves of connected fittings. Hot water may outflow during the drainage! If there is a risk of frost it has to be considered that not only the water in the hot water heater and in the hot water piping may get frozen but also the water in the entire cold water supply piping.
3 OPERATION OF THERMOSTAT Electronic thermostat for controlling electrical water heaters of DZ Dražice allows multiple operating modes along with providing comfort functions. The thermostat contains a display and round controller that allows setting of the heater. OPERATING MODES AND THEIR SYMBOLS Figure 6: Round controller - 16 -...
3.1.1 SMART MODE In this mode the controller passes through two phases in order to save at least 10 % of electric power, comparing to the MANUAL mode. In the first phase in one calendar week the constant temperature of the heater 65 °C is maintained, and the control electronics monitors the user's behavior in terms of water consumption.
3.1.5 OPTIMUM IN MODE MANUAL AND MANUAL HDO Recommended temperature for manual setting (55 °C). During this temperature, the best efficiency of smart heater is achieved. 3.1.6 PROG MODE The mode is similar to MANUAL mode providing two temperatures are set to which the thermostat reacts.
FUNCTION DESCRIPTION In basic mode the panel displays water temperature and uses the light of individual symbols on the round controller to display the actual operating mode. In case of the device defect, the LED display reports the type of detected defect. The tables below display all functions which can be controlled by means of the control panel and set individual heater modes.
SETTING HDO (BULK REMOTE CONTROL) This function works only in the Czech and Slovak Republics. Smart heater includes HDO receiver (bulk remote control). Correct function requires setting the HDO parameters by means of mobile application in the setting section. The setting parameters HDO are detailed in Table 7.
Page 21
Figure 8: Designation A85 CONFIGURATION OF PARAMETERS OPTION Temperature display Active / inactive Preset A 1 - 4 Preset B 1 - 8 Preset DP (P) 1 - 16 Frequency for detection 183.33 Hz, 191 Hz, 194 Hz, 216.66 Hz, 283.33 Hz Table 7: Configurable parameters HDO - 21 -...
CONTROLS DESCRIPTION 3.6.1 MODE CHANGE WITH CONTROLLER Setting the thermostat mode is performed by turning the controller. In case of turning clockwise and anticlockwise, the functions are gradually switched: ANTI-FREEZE, SMART, PROG, MANUAL. Each controller step changes the function to the next or changes temperature during mode MANUAL by 1 °C. 3.6.2 BASIC DISPLAY In all modes during common operation the display contains the actual water temperature in the in the boiler...
3.6.5 FAILURE STATE In case of the defect detected by thermostat, the display shows the defect code: The error codes required by the client are specified in the table below. Failure code Status description Er01 Excessive wear of anode (anode voltage is lower than the limit) Er02 Upper temperature sensor defect Er03...
Figure 9: Error message Er in mobile application 4 SOFTWARE FOR MOBILE DEVICES Basic function software is the thermostat configuration and the display of the actual state. The application is functional: • For the mobile device with the operating system Android 4.3 and higher, •...
Status information include in particular the data on actual water temperature and the set boiler mode (seeFigure 10: Navigation panel) or during vacation. It also displays the orientation information on actually available amount of hot water (after mixing to 40 °C) which is symbolized by the tank icon with changing water level and data in liters (the value is approximate, and it is calculated from the actual temperature sensor value of water in boiler).
Page 26
Figure 11: Signpost at first start - 26 -...
4.1.4 MODE SECTION After pairing the thermostat with the mobile device, the width display in section 'Mode' is set as the home screen, in case of height display it displays the signpost which can navigate to the section 'Mode'. Identically to the real hater, turning the round controller enable setting the required mode (see Figure 12: Mode screen in width display).
Page 28
Figure 13: Setting the program mode Figure 14: Notification of the program mode - 28 -...
4.1.6 VACATION SECTION Section for setting the period when the heater is in mode „ANTI-FREEZE“. The displayed calendar in this case is used only for the vacation deadline visualization, and it has no further function. Information on the ongoing vacation is visibly specified in the status information in the main signpost during the height mode, or on the left panel in the width mode.
Figure 16: Statistics screen 4.1.8 SECTION SETTINGS The SETTING section enables to additionally synchronize boiler time, unless it was completed after starting the application. The name and the capacity of the heater can be changed, too (defined from the production by the production plate), or HDO detection type selected.
Page 31
Figure 17: Setting screen The application is designed for the servicing technicians and contains additional servicing settings which enable to configure the boiler volume or HDO parameters. Figure 18: Setting screen (HDO) - 31 -...
4.1.9 INFO AND TIPS The section contains information on SMART technology with the definition of the main functions and smart boiler modes. 4.1.10 SYNCHRONIZING TIME After the application start, the actual thermostat time is automatically checked. If the time differs from the time in the mobile device, the user can press the button „Synchronize“...
TRANSPORT & STORAGE INSTRUCTIONS The device shall be transported and stored in dry place and protected from weather effects with temperature range from -15 to +50 °C. During loading and unloading the instructions stated on the packaging shall be observed. DISPOSAL OF PACKAGING MATERIAL AND NON- FUNCTIONING PRODUCT A service fee for providing return and recovery of packaging material has been...