Vivotek IP7161 User Manual page 136

Network camera
Table of Contents

Advertisement

VIVOTEK
trigger
di
mdwin
inter
weekday
begintime
endtime
lowlightcondition
136 - User's Manual
boot,
6/6
di,
motion,
seq,
visignal
<integer>
6/6
<integer>
6/6
1~999
6/6
<interger>
6/6
hh:mm
6/6
hh:mm
6/6
0, 1
6/6
Indicate the trigger condition.
"boot" indicates system boot.
"di" indicates digital input.
"motion" indicates video motion detection.
"seq" indicates periodic condition.
"visignal" indicates video input signal loss
Indicate which di detected.
This field is required when trigger condition is "di".
One bit represents one digital input. The LSB
indicates DI 0.
Indicate which motion detection windows
detected.
This field is required when trigger condition is
"md".
One bit represents one window.
st
The LSB indicates the 1
For example, to detect the 1
set mdwin as 5.
Interval of period snapshot in minute.
This field is used when trigger condition is "seq".
Indicate which weekday is scheduled.
One bit represents one weekday.
The bit0 (LSB) indicates Saturday.
The bit1 indicates Friday.
The bit2 indicates Thursday.
The bit3 indicates Wednesday.
The bit4 indicates Tuesday.
The bit5 indicates Monday.
The bit6 indicates Sunday.
For example, to detect events on Friday and
Sunday, set weekday as 66.
Begin time of weekly schedule.
End time of weekly schedule.
(00:00 ~ 24:00 means always.)
Turn on IR led in some condition:
0: all conditions
1: low light condition
window.
st
rd
and 3
windows,

Advertisement