Installation and Removal of the Heat Sink
CEK Heat Sink Installation
1.
Do not apply any thermal grease to the
heat sink or the CPU die; the required
amount has already been applied.
2.
Place the heatsink on top of the CPU so
that the four mounting holes are aligned
with those on the retention mechanism.
3.
Screw in two diagonal screws (i.e. the #1
and the #2 screws) until just snug (do not
over-tighten the screws, which may dam-
age the CPU.)
4.
Finish the installation by fully tightening all
four screws.
Uninstalling the Heat Sink
Warning: We do not recommend removing the CPU or the heat sink.
However, if you do need to uninstall the heat sink, please follow these
!
instructions to avoid damaging the CPU or the CPU socket.
1.
Unscrew and remove the heat sink
screws in the sequence shown in the
picture on the right.
2.
Hold the heat sink as shown in the picture
on the right and gently wriggle to loosen
it from the CPU. (Do not use excessive
force when doing this!)
3.
Once the heat sink is loosened, remove it
from the CPU socket.
4.
Clean the surface of the CPU and the
heat sink to get rid of the old thermal
grease. Reapply the proper amount of
thermal grease before you re-install the
heat sink.
Chapter 5: Advanced Serverboard Setup
Screw #1
Screw #1
Screw #4
5-7
Screw #2
Screw #3
Screw #2