 DISPLAY:
LCD, 128 X 32 pixel bitmapped graphic display
 LOOP POWER:
24VDC regulated output, 100MA max.
 5 USER KEYS:
Up, Down, Left, Right, Enter
 ACCURACY:
0.1% of calibrated span
 LOCKOUT:
User password, user configurable
 INPUT IMPEDANCE:
Voltage 100K, current 100 OHMS
 POWER:
120VAC (230VAC available)
 ENVIRONMENTAL:
Operating, 0-65 C
Storage, -40 -80 C
R.H., 0-90% non condensing
 ENCLOSURE:
¼ DIN, ABS plastic 96 X 96 X 150MM (main unit) back panel din rail mount aux unit 6" x
4.5" x 2.5"
 FRONT PANEL:
Gasketed Nema 4X
 ACCESS: (DIN CASE)
Chassis & boards remove from front of case.
 TERMINAL STRIP:
(60) Removable for ease of wiring 28 – 16 AWG
 CONNECTIONS:
Removable screw terminal blocks 28 – 16 AWG wire.
 CONTROL OUTPUTS:
4 relay outputs, user programmable, SPDT Form 'C' relays 5 AMP.
4 digital outputs, Opto isolated, open collector.
 OUTPUT ANNUNCIATION:
On board piezo buzzer