Troubleshooting The Microprocessor - Dell PowerEdge NM176 Hardware Owner's Manual

Dell server hardware owner's manual
Table of Contents

Advertisement

9 Remove all expansion cards installed in the system. See "Removing an
Expansion Card" on page 78.
10 Close the system. See "Closing the System" on page 55.
11 Reconnect the system to the electrical outlet, and turn on the system and
attached peripherals.
12 Run the appropriate online diagnostic test.
If the tests fail, see "Getting Help" on page 127.
13 For each expansion card you removed in step 9, perform the following
steps:
Turn off the system and attached peripherals, and disconnect the
a
system from the electrical outlet.
Open the system. See "Opening the System" on page 54.
b
Reinstall one of the expansion cards.
c
Close the system. See "Closing the System" on page 55.
d
Run the appropriate diagnostic test.
e
If the tests fail, see "Getting Help" on page 127.

Troubleshooting the Microprocessor

Problem
Error message indicates a microprocessor problem.
A heat sink is not installed for the processor.
Action
CAUTION:
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
1 Run the appropriate online diagnostics test. See "Using Dell PowerEdge
Diagnostics" on page 117.
2 Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.
114
Troubleshooting Your System
Only trained service technicians are authorized to remove the system