Troubleshooting a Fan

Problem
System-status indicator is amber.
Systems management software issues a fan-related error message.
Action
CAUTION:
cover and access any of the components inside the system. Before performing any
procedure, see your Product Information Guide for complete information about
safety precautions, working inside the computer and protecting against
electrostatic discharge.
1 Run the appropriate diagnostic test. See "Using Dell PowerEdge
Diagnostics" on page 117.
2 Open the system. See "Opening the System" on page 54.
3 Ensure that the faulty fan's power cable is firmly attached to the fan power
connector. See "Fan Assembly" on page 68.
NOTE:
whether it is working properly.
4 If the problem is not resolved, install a new fan. See "Fan Assembly" on
page 68.
If the replacement fan is working properly, close the system. See "Closing
the System" on page 55.
If the replacement fan does not operate, see "Getting Help" on page 127.