Table 1-4. System Messages (continued)
Message
Manufacturing mode
detected
Memory address line
failure at address ,
read value
expecting value
Memory double word
logic failure at
address , read value
expecting value
Memory odd/even
logic failure at
start address to
end address
Memory write/read
failure at address ,
read value
expecting value
Memory tests
terminated by
keystroke
No boot device
available
Causes
System is incorrectly
configured.
Faulty or improperly
installed memory modules,
or faulty system board.
The spacebar was pressed
during POST to terminate
the memory test.
The system cannot find the
diskette or hard drive.
Corrective Actions
Ensure that all memory
modules are properly
installed. See
"Troubleshooting System
Memory" on page 108. If
the problem persists, see
"Getting Help" on
page 127.
Information only.
If the diskette drive is your
boot device, ensure that a
bootable disk is in the drive.
If the hard drive is your
boot device, ensure that the
hard drive is installed,
properly seated, and
partitioned as a boot
device.
Enter the System Setup
program and verify the boot
sequence information. See
your Hardware Owner's
Manual for details.