Translation of copy in original language IMPORTANT: MUST BE READ 831086700 rev. 1.0 12/04/2024 Installation, use and maintenance manual PELLET STOVE SILENCE PLUS / TRINITY PLUS...
Each stove is subjected to internal testing before shipment and as such residues inside the appliance may be found. Eva Stampaggi aims to provide as much information as possible to ensure safer use and to avoid damage to persons, property or parts of the stove itself.
● Read the manual carefully: ● Eva Stampaggi S.r.l. assumes no responsibility for damage to persons and/or property or for the malfunction of the stove resulting from non-compliance with the provisions of this Instruction Manual ● The guarantee will remain valid for 1 year for professional operators and 2 years for consumers ●...
Page 5
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE ATTENTION ATTENTION! DO NOT TOUCH the FIRE DOOR, the GLASS, the HANDLE or the FUME OUTLET DURING FUNCTIONING if not wearing adequate protective devices since they become extremely hot! ●...
Page 6
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE ATTENTION These stoves operate exclusively with pellets and olive pomace if the stove is designed for it; DO NOT USE DIFFERENT COMBUSTIBLES: any other material burned will cause the apparatus to malfunction. ATTENTION Clean the burn pot on a regular basis upon every ignition or pellet refuelling.
INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED. INSTEAD THE FUME OUTLET MUST BE ROOF- TYPE AS PROVIDED FOR BY NATIONAL REGULATIONS. Eva Stampaggi S.r.l. assumes no responsibility for damage to persons and/or property caused by non-compliance with the point highlighted above for products installed in a non-compliant manner.
Page 8
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE 3 issuing of additional documentation - the installer's responsibility. The release of technical documentation must include: ● use and maintenance manual for the appliance and the components of the system (e.g. smoke channels, chimney flue, etc.);...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE INSTALLATION FLUE PIPE THE PRODUCTION OF STOVES WITH HIGHER PERFORMANCE IS INCREASINGLY REQUIRED SO IT IS BECOMES ESSENTIAL TO ENSURE THAT INSTALLATIONS COMPLY WITH THE LAW. IF THE VENT PIPE PASSES THROUGH NON-HEATED ENVIRONMENTS, IT MUST BE INSULATED FOR CORRECT COMBUSTION.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE CHIMNEY COWL A properly installed chimney cowl ensures optimum stove functioning. The anti-downdraught chimney cowl consists of a number of components whose outlet section sum always doubles the flue pipe section. Make sure the chimney cowl is at least 150cm above the roof rise so that it is fully exposed to the wind.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE DRAUGHT Fumes heat up during combustion, increasing their volume. Their density is therefore lower than the one of the surrounding colder air. This difference between the inside and outside temperatures of the chimney results in a negative pressure which increases proportionally to the vent pipe length and the temperature.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE ATTENTION Read the manual carefully: Before installing, the following indications must be met: Select the position where the stove is to be installed and: ● Arrange the connection to the vent pipe for fume extraction. ●...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE INSTALLATION PLACE ATTENTION Read the manual carefully: ● When the stove is on, it can create a depression in the room where it is installed, therefore there must not be any open flame apparatus in the same room, with the exception of type C boilers (airtight).
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE CONNECTION TO THE FLUE PIPE THE LENGTH OF THE FUME DUCT PIPE MUST HAVE A DIAMETER EQUAL TO OR GREATER THAN THAT SPECIFIED FOR EACH APPLIANCE. EVERY 90° ELBOW OR (T) COUPLING IS THE EQUIVALENT OF 1 METRE OF PIPE.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE INSTALLATION EXAMPLES Key: T - T fitting; Ø ST - Stove diameter T; RAC Ø ST Ø CF - Stove and smoke duct connection; Ø CF - Smoke duct diameter; IS - Insulator;...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE ELECTRICAL CONNECTION The electrical connection must be performed by qualified personnel who install circuit breakers upstream of the appliance. Special attention should be paid when the operation is a supplementary action and all equipment must operate as planned.
Upper Flue Exhaust ---- ---- Weight Tank capacity Size of heated room 150-210 180-270 160-220 Silence Plus 9 Silence Plus 11 Trinity Pellet Consumption (kg/h) Flue Temperature (°C) Gas Flow (g/s) Minimum Draft (Pa) Voltage / Frequency (V/Hz) 230 / 50...
Page 18
(Ppilot) Carefully read the installation, use and maintenance instructions. Eva Stampaggi S.r.l. Via Cal Longa Z.I. 31028 Vazzola (TV) ITALY P.IVA: 01183110269 Tel. +39 0438 740433 Fax. +39 0438 740821 e-mail: info@evacalor.it Based on EU regulation 305/2011, the declaration of performance (DoP) is available on the websites: www.evacalor.it...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE PRODUCT SPECIAL FEATURES INSTALLATION In case of installation with upper flue outlet, it is necessary to break the pre-cut present in the top of the product. Use a hammer and with a firm blow break the pre-cut.
Page 20
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE PANEL DESCRIPTION Button P1 – Increase: When in programming mode, use this button to modify/increase the selected menu value. When in working/switched off mode, instead use this button to increase the room thermostat temperature value or stove heat output. Button P2 –...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE Use this function to set current time and date. The control board is equipped with a lithium battery guaranteeing the time clock 3/5 year-long autonomy. Set the current date by pressing OK and the respective arrows to increase or decrease the selected values.
Page 22
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE After the temperature of the fumes has reached and exceeded a given value and has maintained it for at least a predetermined time, the stove goes into work mode which is the normal working mode. The upper display shows the time and the room temperature and the lower one the set power and the power in which the stove is found.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE ALARMS In the event that an operating fault occurs, the board intervenes and signals the occurrence of an irregularity, switching on the alarm LED (alarm LED on) and emitting acoustic signals. The possible alarm messages are listed below: Display shows Cause POWER OUTAGE ALARM...
ATTENTION Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused by the failure/incorrect cleaning and routine maintenance of the stove.
Page 25
SILENCE PLUS / TRINITY PLUS - PELLET STOVE ATTENTION Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction and those resulting from people or things caused by the failure/incorrect extraordinary maintenance of the stove.
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE TROUBLESHOOTING FIRST START-UP FIRST START-UP IT MAY BE NECESSARY TO REPEAT THE FIRST LOAD PHASE A FEW TIMES TO FACILITATE THE APPLIANCE INITIAL START-UP AS THE AUGER TUBE IS COMPLETELY EMPTY AND IT MAY TAKE A SPECIFIC PERIOD OF TIME TO FILL.
Page 27
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE PROBLEM CAUSE SOLUTION POWER OUTAGE CHECK PLUG AND POWER SUPPLY OR ON/OFF SWITCH CALL TECHNICAL ASSISTANCE. FAULTY ELECTRICAL CABLE CALL TECHNICAL ASSISTANCE. DISPLAY INTERRUPTED FUSE IN CONTROL SWITCHED OFF BOARD CALL TECHNICAL ASSISTANCE.
Page 28
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE PROBLEM CAUSE SOLUTION STOP FIRE CLN-BURN POT PERIODIC CYCLE OF BURN POT CORRECT OPERATION. CLEANING CLEAN BURN POT CLEAN BURN POT ALAR DEP FAIL FIREPLACE NOT COMPLIANT, MAX 6 METRES OF TUBE ACTIVE ALARM EXCESSIVE OR INADEQUATE VENT WITH Ø...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE PROBLEM CAUSE SOLUTION (FIELD SEARCH) REMOTE CONTROL HAS LOST THE PRESS THE KEYS 1 AND 2 SIMULTANEOUSLY FOR REMOTE CONTROL UNIT ABOUT 3-4 SECONDS UNTIL THE "CHOOSE UNIT" DOES NOT APPEARS POSSIBLE INTERFERENCE...
Installation, use and maintenance manual SILENCE PLUS / TRINITY PLUS - PELLET STOVE 10 INSTALLATION AND TEST CERTIFICATE CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER STREET/ROAD: CITY: POSTAL CODE: PROVINCE TEL: Delivery date: Delivery document: Equipment mod.: Serial number: Year: DEALER and INSTALLER DATA First name: Last Name: Address:...
EN 303-5:2012 (pellet boilers) Eva Stampaggi S.r.l. guarantees that the stove is free from defects that make it unsuitable for its intended use or significantly reduce its value. The rules of the Italian Civil Code or applicable national law governing the guarantee in the sales contract, or applicable national law ex D.
Page 32
AN INSTALLATION ACCORDING TO THE LAW IS MANDATORY, EVA STAMPAGGI STRONGLY RECOMMENDS A FIRST IGNITION OF ITS PRODUCTS WITH A QUALIFIED TECHNICIAN. EVA STAMPAGGI HAS NO LIABILITY OF ONLINE SALES AND RELATED OFFERS, BECAUSE IT DOES NOT MAKE DIRECT SALES TO THE GENERAL PUBLIC.
Page 33
EVA STAMPAGGI SRL reserves the right to make technical changes to this manual without notice. The data and characteristics indicated do not bind , which reserves the right to make any changes deemed appropriate without obligation of notice or replacement.