Planet IGS-4215-16P4X Quick Installation Manual

Industrial l2+ managed gigabit switch with 10g uplink

Advertisement

Quick Links

Industrial L2+ Managed Gigabit Switch with
10G Uplink
IGS-4215 DIN-rail Series
Quick Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IGS-4215-16P4X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Planet IGS-4215-16P4X

  • Page 1 Industrial L2+ Managed Gigabit Switch with 10G Uplink IGS-4215 DIN-rail Series Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ..................3 2. Requirements ....................4 3. Wiring the Power Inputs ................. 5 3.1 Grounding the Device ................7 4. Terminal Setup ....................8 4.1 Logging on to the Console ............... 9 4.2 Configuring IP Address via Console ............10 4.3 Storing Current Switch Configuration ............
  • Page 3: Package Contents

    1. Package Contents Thank you for purchasing one of PLANET L2+ Managed Gigabit Switch series. The descriptions of these models are shown below: Industrial L2+ 8-Port 10/100/1000T + 4-Port 10G SFP+ IGS-4215-8T4X Managed Ethernet Switch (-40~75 degrees C) Industrial L2+ 8-Port 10/100/1000T 802.3bt PoE + 4-Port 10G IGS-4215-8UP4X SFP+ Managed Ethernet Switch (-40~75 degrees C) Industrial L2+ 16-Port 10/100/1000T + 4-Port 10G SFP+ IGS-4215-16T4X Managed Ethernet Switch (-40~75 degrees C) Industrial L2+ 16-Port 10/100/1000T 802.3at PoE + 4-Port 10G IGS-4215-16P4X SFP+ Managed Ethernet Switch (-40~75 degrees C) Industrial L2+ 24-Port 10/100/1000T + 4-Port 10G SFP+ IGS-4215-24T4X Managed Ethernet Switch (-40~75 degrees C) “Industrial Managed Switch” is used as an alternative name in this Quick Installation Guide.
  • Page 4: Requirements

    2. Requirements z Workstations running Windows 8/10/11, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. z Workstations are installed with Ethernet NIC (Network Interface Card) z Serial Port Connection (Terminal)  The above Workstations come with USB ports.  The above Workstations have been installed with terminal emulator, such as Tera Term or PuTTY.  USB cable -- one end is attached to the USB Type A/Type C port on the workstation, while the other end is connected to the USB Type C console port of the Industrial Managed Switch.
  • Page 5: Wiring The Power Inputs

    3. Wiring the Power Inputs The Upper Panel of the Industrial Managed Switch indicates an inlet power socket and consists of one green terminal block connector with 6 contacts. Please follow the steps below to insert the power wire. 1. Insert positive and negative DC power wires into contacts 1 and 2 for Power 1 or 5 and 6 for Power 2.
  • Page 6 2. The power input range of each model is shown below: Model Input Power Range (DC) Input Power Range (AC) IGS-4215-8T4X 9V ~ 48V IGS-4215-8UP4X 48 ~ 54V IGS-4215-16T4X 9V ~ 48V IGS-4215-16P4X 48 ~ 54V IGS-4215-24T4X 9V ~ 48V PWR1 and PWR2 must provide exactly the same DC voltage for power load balance while operating with dual power input.
  • Page 7: Grounding The Device

    3.1 Grounding the Device Users MUST complete grounding wiring with the device; otherwise, a sudden lightning could cause fatal damage to the device. DC Input: 9-48V , 3A max. AC Input: 24V , 2A max. 1 2 3 4 5 6 PWR1 Alarm PWR2...
  • Page 8: Terminal Setup

    4. Terminal Setup To configure the system, connect one end of a USB data cable to a USB port on a PC or notebook computer and the other end to the USB Type-C console port of the Industrial Managed Switch. PC / Workstation with Terminal Emulation Software...
  • Page 9: Logging On To The Console

    (1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation. PLANET Technology Corp. Made in Taiwan Figure 4-3: MAC ID Label Enter the default username and password, then set a new password according to the rule-based prompt and confirm it. Upon success, press any key to return to the...
  • Page 10: Configuring Ip Address Via Console

    4.2 Configuring IP Address via Console The IGS-4215 series supports IP static routing, which requires specific command lines to display and modify its IP settings. The Industrial Managed Switch is shipped with the default IP address as follows: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Industrial Managed Switch, please use the procedure as follows: ...
  • Page 11: Storing Current Switch Configuration

    3. Repeat the previous steps to check if the IP address has changed. If the IP is successfully configured, the Industrial Managed Switch will apply the new IP address setting immediately. You can access the Web interface of Industrial Managed Switch through the new IP address. 4.3 Storing Current Switch Configuration 1. At the “IGS-4215-24T4X#”...
  • Page 12: Starting Web Management

    5. Starting Web Management The following shows how to start up the Web Management of the Industrial Managed Switch. Note the Industrial Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set to the same IP subnet address. For example, the default IP address of the Industrial Managed Switch is 192.168.0.100, then the manager PC should be set to 192.168.0.x (where x is a number between 1 and 254, except 100), and the default subnet mask is 255.255.255.0.
  • Page 13 3. After logging in, you will be prompted to change the initial password to a perma- nent one. Figure 5-2: Create a New Password 4. Once the password change is complete, re-enter the web interface using your new password and the main screen appears as Figure 5-3 shows. Figure 5-3: Web Main Screen of Industrial Managed Switch The Switch Menu on the left of the Web page lets you access all the commands and statistics the Industrial Managed Switch provides.
  • Page 14: Saving Configuration Via Web

    Figure 5-6: Switch Sub-menu (Note that the IGS-4215-8UP4X/IGS-4215-16P4X model includes an additional PoE sub-menu.) Now, you can use the Web management interface to continue the Switch management. Please refer to the user’s manual for more. 5.2 Saving Configuration via Web To save all applied changes and set the current configuration as a startup configuration, the startup-configuration file will be loaded automatically across a system reboot.
  • Page 15: Restoring Default Configuration

    6. Restoring Default Configuration  IP Address has been changed or admin password has been forgotten – To reset the IP address to the default IP Address “192.168.0.100” or reset the login password to default value, press the hardware-based reset button on the front panel for about 10 seconds. After the device is rebooted, you can log in the management Web interface within the same subnet of 192.168.0.xx.
  • Page 16 1000 LNK/ACT 10/100 LNK/ACT Alarm Ring R.O. USB Console 115200,n,8,1 Reset Button Reset 1G/2.5G LNK/ACT 100/10G LNK/ACT IGS-4215-16T4X Figure 6-2: IGS-4215-16T4X/IGS-4215-16P4X Reset Button Reset Button 1000 LNK/ACT Alarm 10/100 LNK/ACT Reset Ring R.O. USB Console 115200,n,8,1 1G/2.5G LNK/ACT IGS-4215-24T4X 100/10G...
  • Page 17: Customer Support

    7. Customer Support Thank you for purchasing PLANET products. You can browse our online FAQ resource and User’s Manual on PLANET Web site first to check if it could solve your issue. If you need more support information, please contact PLANET switch support team. PLANET online FAQs: https://www.planet.com.tw/en/support/faq Switch support team mail address: support@planet.com.tw IGS-4215 DIN-rail Series User’s Manual: https://www.planet.com.tw/en/support/downloads?&method=keyword&keyword=igs- 4215&view=3#list (Please select your switch model name from the Product Model drop-down menu) Copyright © PLANET Technology Corp. 2025. Contents are subject to revision without prior notice.

Table of Contents