  • Page 1 Powerful Stirring Betriebsanleitung Operating instructions Notice d'instructions Hei-TORQUE Core...
  • Page 2: Table Of Contents

    Special hygiene measures for the use of laboratory equipment in food, cosmetics and pharmaceutical production ..........37 General Measures ....................37 Device-specific measures ..................37 Other regulations .................. 38 Device description Overview of the Hei-TORQUE Core overhead stirrer ........39...
  • Page 3 Device service ..................53 General cleaning instructions ................53 Repairs ......................53 Maintenance ...................... 53 Disposal......................54 Contact information Heidolph international ..........54 Warranty Statement ................54 Declaration of no objection ..............55 Certifications EU Declaration of Conformity ..............84 UKCA Declaration of Conformity ..............
  • Page 4: About This Document

    Introduction About this document These operating instructions describe all functions and operation of overhead stirrers of the type Hei-TORQUE Core. The operating instructions are an integral part of the delivery. Typographic conventions Standardized symbols, highlighting elements, and signal words are used in this docu- ment to identify warnings, cautions, important information, and special text contents.
  • Page 5: General Notes

    The Hei-TORQUE Core overhead stirrers have been specifically developed for the following tasks: Stirring, mixing, gassing and degassing, emulsifying, suspending. The Hei-TORQUE Core overhead stirrers are suitable for use in the following areas: Chemical, pharmaceutical, biology, environmental analysis, basic research, research laboratories.
  • Page 6: Transportation

    General notes Compliance with and implementation of all relevant guidelines and safety measures for the respective field of application is within the sole responsibility of the operator. All risks resulting from improper use are solely borne by the operator. The described product may only be operated by authorized and instructed personnel. Training and qualification of the operating personnel as well as ensuring that the product is operated with responsibility are the sole responsibility of the operator! Transportation...
  • Page 7: Safety

    ➜ Have repairs and/or maintenance work on the device carried out exclusively by an authorized electrician or by the technical service department of Heidolph Instruments. ➜ Always switch off the device and disconnect it from the power supply before carrying out maintenance, cleaning, or repair work.
  • Page 8: Work Safety

    Safety Work safety ➜ Always use the prescribed personal protective equipment (PPE) such as protective clothing, safety goggles, protective gloves, safety shoes, etc. ➜ Do not operate any other devices in the immediate vicinity of the device ... – which can generate electromagnetic fields in the frequency range between 9 ×...
  • Page 9: Special Hygiene Measures For The Use Of Laboratory Equipment In Food, Cosmetics And Pharmaceutical Production

    Make sure that even products that are intended for single use only are of sufficient purity. ➜ Do not use open containers. ➜ Avoid contamination by handling contaminated vessels, apparatus or aids with care. Contact information For further information, please contact our after sales service at any time. Phone: +49-9122-9920-0 Mail: sales@heidolph.de...
  • Page 10: Other Regulations

    In case of disregard of the above-named regulations and safety measures and/or in case of noncompliance, all warranty claims against Heidolph Instruments become invalidated. The operator is solely liable for all damage resulting from unau- thorized changes or modifications to the unit, from the use of...
  • Page 11: Device Description

    Device description Device description Overview of the Hei-TORQUE Core overhead stirrer...
  • Page 12: Mounting The Support Rod

    ➜ Turn the grub screw counterclockwise to loosen and dismantle the support rod. ➜ Then fix the fitted support rod to an adequately load-bearing wall grid or a stand with the help of suitable clamps (for suitable accessories, see www.heidolph.com).
  • Page 13: Set Up The Device

    Commissioning Set up the device The described overhead stirrers can be mounted on a stand or on a wall grid. Any necessary mounting materials are available as accessories, see www.heidolph.com. Follow the safety instructions below: WARNING Risk of injury, risk of damage to property due to fall or tilting...
  • Page 14: Chuck For Stirrer Tools

    Commissioning Chuck for stirrer tools WARNING Risk of injury due to rotating parts ➜ Before mounting/dismantling the chuck, switch off the device and disconnect it from the power supply to prevent unexpected starting-up of the device! The chuck is fixed on the stirrer shaft by a grub screw so that it cannot rotate: Inserting and locking the chuck ➜...
  • Page 15: Clamping/Removing Stirrer Tools

    Commissioning Clamping/removing stirrer tools WARNING Risk of injury due to rotating parts ➜ If necessary, stop the rotational movement and before clamping/ removing stirrer tools, switch off the device to prevent it from starting up unexpectedly! Proceed as follows to clamp/remove stirrer tools: ➜...
  • Page 16: Power Supply

    Commissioning Power supply The device has an appliance outlet with locking system for the power supply. A suitable three-pole power supply cord is included in the scope of delivery. DANGER Electric shock, damage to property, loss of production ➜ The device may only be supplied with the required line voltage via a grounded power socket.
  • Page 17: Automatic Restart

    Commissioning Automatic restart This function can be used to set the device so that the stirrer is restarted automatically after being switched off or after a power outage, and the speed is run up to the last set value. CAUTION ➜...
  • Page 18: Operation

    ➜ The actual display is shown on the display as the actual value, see also section “Overview of the Hei-TORQUE Core overhead stirrer” on page 39. Starting/stopping rotation Start and stop the rotational movement by pressing the speed controller.
  • Page 19: Overload Protection

    Overload protection The device is equipped with an overload protection function: The performance indicator on the display (see section “Overview of the Hei-TORQUE Core overhead stirrer” on page 39) visualizes the effective loading in the form of a progress bar.
  • Page 20: Fast Mode

    Operation ➜ If the rotational movement is stopped before the timer has expired, it is stopped and continues running when the rotational movement restarts. ➜ If the timer time expires normally (no interruption due to manual stopping of the rotational movement), the rotational movement is stopped automatically and the timer is reset to the set time, e.g.
  • Page 21: Troubleshooting

    Automatic shutdown. Allow the motor to cool and switch the device back on If a fault cannot be rectified with the described suggestions, please contact an autho- rized sales representative or our technical service (see section “Contact information Heidolph international” on page 54).
  • Page 22: Appendix

    Appendix Appendix Technical Specifications Model Hei-TORQUE Core Dimensions 70 × 282 × 195 (W × H × D, in mm) Weight (kg) Stirrer shaft retainer 0.5 – 10.5 (∅ in mm) Control panel TFT display, monochrome, 2 inch Speed range (rpm) 20 –...
  • Page 23: Recommended Speeds

    Appendix Recommended speeds Stirrer tool Maximum rpm Blade impeller: BR 10, BR 11, BR 12, BR 14 ≤ 2,000 ≤ 800 Blade impeller: BR 13 ≤ 800 Half-moon impeller: H 18 ≤ 800 Pitched-blade impeller: PR 39, PR 33 ≤ 2,000 Pitched-blade impeller: PR 30, PR 31, PR 32 ≤...
  • Page 24: Scope Of Delivery

    Item Product number tity Hei-TORQUE Core 501-61011-00 Support rod 22-02-14-01-41 Operating instructions 01-005-005-82 Guarantee registration / Declaration of no objection 01-006-002-78 Power supply cord country-dependent Further information, particularly on the available accessories can be found on our website at www.heidolph.com!
  • Page 25: Device Service

    “Declaration of no objection” on page 55. Maintenance The device contains no user-serviceable components. If necessary (in the event of abnormal operating behavior such as excessive noise or heat generation, for example), contact our technical service, see “Contact information Heidolph international” on page...
  • Page 26: Disposal

    Phone: 01799 - 5133-20 E-mail: service@radleys.co.uk www.heidolph-instruments.co.uk Local distributors To find your local distributor please visit www.heidolph.com Warranty Statement Heidolph Instruments provides a three-year warranty against mate- rial and manufacturing defects. Glass and wear parts, transportation damage, and damage resulting from improper handling or non-intended use of the product are excluded from the warranty.