Initial Setup Continued
7� See Figure 7� To release the pressure, rotate
the system pressure manual release valve to the
release (lever away from the motor) position�
HOLD
HOLD
RELEASE
RELEASE
NOTE: Pressure is retained until it is released
with the system pressure release valve lever.
8� See Figure 8� Disconnect the power cord�
Bleeding Air from the System
1� Cycle the hydraulic system until operation is smooth and consistent�
2� Check the pump reservoir level� Add Power Team hydraulic fluid or equivalent as needed�
Air can accumulate in the hydraulic system during
the initial set-up or after prolonged use causing the
tool to respond slowly or in an unstable manner� To
remove the air:
3� See Figure 9� Open the filler cap two full turns�
© SPX FLOW, Inc.
Figure 7. Release Position
Figure 8. Disconnected from
Power Source
Figure 9. Filler Cap
8
Form No.
1000591
Rev. 2
May. 30, 2022
Need help?