  • Page 1 Test & Inspection FlowScout SE100 ™ Single-ended Loss Test Set Quick Reference Guide www.AFLglobal.com | +1 (800) 235-3423...
  • Page 2 Detection of the reflector means there is continuity to the end of the fiber. When an optical reflector is detected, the FlowScout SE100 measures insertion loss to the reflector at 1430 nm wavelength.
  • Page 3 General FlowScout SE100 Example Applications ™...
  • Page 4 SE100 contains no user-serviceable parts. It ™ must be returned to AFL or an authorized service center for repair and calibration. IMPORTANT: 85% of network outages are due to dirty connectors. Use the ICIC (Inspect-Clean-Inspect-Connect) method to eliminate these issues. Always inspect each connector, clean if necessary, inspect again to verify it is clean, and then connect.
  • Page 5 Controls, Display, Interfaces 1. SC-APC connector 2. Protective dust cap 3. Micro-USB port: used for Software update, external 5VDC operation 4. LCD display: Shows measurements and prompts 5. Status indicators: Reflector Detected: Fiber connected and 1430 nm Wavelength Optical Reflector detected Not Detected: Fiber not connected, or fiber connected but 1430 nm Wavelength Optical Reflector not detected 6.
  • Page 6: Basic Operation

    Notes: The FlowScout SE100 will auto-off after a period of inactivity. • To manually turn off the FlowScout SE100, press and hold the power button. • 2. On power-up, FlowScout SE100 will perform the following Perform LED and LCD test.
  • Page 7 If measured loss is >10 dB, high loss will be indicated. Not Detected Network segment is terminated in FlowScout SE100 display will alternate between 'HI REFL' a 1430 nm reflector, but excessive and the Optical Return Loss (ORL) at 1550 nm.
  • Page 8 Interpreting Indicators and Displays Display Status LED Interpretation       Not Detected Fiber with reflector not detected; Connect fiber     Not Detected Live fiber detected; Unable to test Alternating  and Not Detected Fiber connected;...
  • Page 9 1430 nm Wavelength Optical Reflector and the reflected light stored as the 0.0 dB reference. All FlowScout SE100 testers have a 0.0 dB reference stored when shipped from the factory. However, if tester or patch cord connectors are dirty or damaged, FlowScout SE100 may report higher than expected insertion loss. If negative loss measurements are reported along with 'Poor Ref', this is an indication FlowScout SE100 was re-referenced using a dirty or damaged patch cord or reflector.
  • Page 10 If patch cord with the reflector is connected and measured loss relative to factory-stored reference is ≤3.0 dB: • FlowScout SE100 will store the reflected power as new 0.0 dB reference – Then it will resume measuring loss at 1430 nm –...
  • Page 11: Battery Replacement

    Battery Replacement If the FlowScout SE100 fails to turn on or indicates low battery warning, replace two alkaline AA batteries ™ as follows: Remove the rubber boot • Open the battery compartment on the back • Remove the discharged 2 x AA batteries and replace with fully-charged batteries •...