Page 1
WALL UNIT 600, Tall Boiler Housing Assembly Guide 600 TALL For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 2
WALL UNIT 600, Tall Boiler Housing Assembly Guide BEFORE YOU START INSTALLATION SHOULD BE PERFORMED BY A COMPETENT PERSON ONLY. THIS PRODUCT COULD BE DANGEROUS IF INCORRECTLY INSTALLED NOT to be used with CAM LOCK Page 2 For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 3
WALL UNIT 600, Tall Boiler Housing Assembly Guide Panel C Panel D Panel A Frontal x1 Fixed Shelf x1 Rail x1 Front Panel x2 End Panel (Packed Separetely) Page 3 For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 4
WALL UNIT 600, Tall Boiler Housing Assembly Guide (F) x8 (S) x4 (L) x2 (K) x4 (G) x6 (H) x6 Wooden 20mm 15mm 30mm Cam Lock Cam Dowel Dowel Screw Screw Screw (Expanding) Hanging Bracket Plate L Bracket SML (M) x4 (N) x1 Cover Cap Door Buffer...
Page 5
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 1. Seat dowels (F) into holes in both end panels (A) as shown. Page 5 For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 6
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 2. Seat expanding cam dowels (G) into holes in both end panels (A) as shown. Page 6 For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 7
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 3. Attach panel (C) and (D) to panels (A) using expanding cam dowels (G), and wooden dowels (F) in positions as shown. All cam locks holes (H) are to be positioned facing the outside of the unit carcase, for ease of tightening.
Page 8
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 4. Insert cam locks (H) and hand tighten them, this will expand cam dowels (G) and tighten the unit together. Do not use power tools with cam lock (H) Page 8 For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 9
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 5. Attach hinge plates onto both end panels (A) as shown, using 2 screws already located in hinge plates. Hinge to be mounted in accordance to customer specific kitchen plan. From Top 94mm 126mm INSIDE FACE...
Page 10
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 6. Hanging brackets steps A, B & C to be carried out on both sides as shown. A. Insert hanging bracket into pre-drilled holes. B. Rotate locking lever 180 degrees. C. Secure with provided 2 x 20mm screws (S) per bracket. Screws for attaching to walls are not provided as these vary depending on materials, thickness and construction.
Page 11
WALL UNIT 600, Tall Boiler Housing Assembly Guide Care to be taken. Hanging procedure is necessary for a safe installation. Screws for attaching to walls are not provided as these vary depending on materials, thickness and construction. Ensure appropriate fixings for wall construction are used. Step 8.
Page 12
WALL UNIT 600, Tall Boiler Housing Assembly Guide Step 10. Using points a, b & c adjust the unit to suit. Point a. Rotate the top screw clockwise to move the unit up. Anti-clockwise for down. Point b. Adjust the depth using centre screw. Point c.
Page 13
WALL UNIT 600, Tall Boiler Housing Assembly Guide HINGE ATTACHMENT AND ADJUSTMENT Step 1. Insert hinges into frontal hinge holes provided, secure hinges with Hinge dowels the 2 x screws and hinge dowels already located in the hinges. Step 2. Attach the door to unit, clip hinges onto hinge plates and click to secure.
Page 14
WALL UNIT 600, Tall Boiler Housing Assembly Guide For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...
Page 15
WALL UNIT 600, Tall Boiler Housing Assembly Guide For Internal Use: FI.WR.INS.039_WKIN00129_Wall_600_BlrHsg_Rev9...