Troubleshooting A Damaged System - Dell PowerEdge R710 Series Hardware Owner's Manual

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R710 Series:
Table of Contents

Advertisement

Power supplies
Processors and heat sinks
Memory modules
Fan bracket
4 Let the system dry thoroughly for at least 24 hours.
5 Reinstall the processors and heat sinks, memory modules, power supplies,
cooling shroud, and fan bracket.
6 Close the system. See "Closing the System."
7 Reconnect the system to the electrical outlet, and turn on the system.
If the system does not start properly, see "Getting Help."
8 If the system starts properly, shut down the system and reinstall the rest of
the components that you removed in step 3. See "Installing an Expansion
Card."
9 Run the appropriate online diagnostic test. See "Using Dell™ PowerEdge™
Diagnostics."
If the tests fail, see "Getting Help."

Troubleshooting a Damaged System

CAUTION:
Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and
support team. Damage due to servicing that is not authorized by Dell is not covered
by your warranty. Read and follow the safety instructions that came with the
product.
1 Turn off the system and attached peripherals, and disconnect the system
from the electrical outlet.
2 Open the system. See "Opening the System."
3 Ensure that the following components are properly installed:
Expansion cards and both expansion-card risers
Power supplies
Fans and cooling shroud
Processors and heat sinks
Troubleshooting Your System
157

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R710 - poweredge - 4 gb ramExternal oemr xl v2 r710

Table of Contents