Table 1-1. LCD Status Messages (continued)
Code
Text
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
E122A CPU # VTT
Regulator
failure.
Reseat CPU.
E122C CPU Power
Fault. Power
cycle AC.
E122D Memory
Regulator #
Failed.
Reseat DIMMs.
E122E On-board
regulator
failed. Call
support.
E1310 Fan ## RPM
exceeding
range. Check
fan.
E1311 Fan module ##
RPM exceeding
range. Check
fan.
Cause
Specified processor
VCORE voltage regulator
has failed.
Specified processor VTT
voltage regulator has failed.
A power fault was detected
when powering up the
processor(s).
One of the memory
regulators has failed.
One of the on-board
voltage regulators failed.
RPM of specified fan is
outside of the intended
operating range.
RPM of specified fan in
specified module is outside
of intended operating
range.
Corrective Actions
Reseat the processor(s).
See "Troubleshooting the
Processor(s)."
If the problem persists,
see "Getting Help."
Reseat the processor(s).
See "Troubleshooting the
Processor(s)."
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Reseat the memory
modules. See
"Troubleshooting System
Memory."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
See "Troubleshooting
System Cooling
Problems."
See "Troubleshooting
System Cooling
Problems."
About Your System
25

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R710 - poweredge - 4 gb ramExternal oemr xl v2 r710