Table 1-2. System Messages (continued)
Message
Warning! Power
required exceeds
PSU wattage.
Check PSU and
system
configuration.
Warning!
Performance
degraded. CPU and
memory set to
minimum
frequencies to
meet PSU wattage.
System will
reboot.
Warning! PSU
mismatch. PSU
redundancy lost.
Check PSU.
Warning!
Unsupported
memory
configuration
detected. The
memory
configuration is
not optimal. The
recommended
memory
configuration
is: <message>
52
About Your System
Causes
The system configuration of
processor(s), memory
modules, and expansion
cards may not be supported
by the power supplies.
A High Output power supply
and an Energy Smart power
supply are installed in the
system at the same time.
Invalid memory
configuration. The system
will run but with reduced
functionality.
Corrective Actions
If any system components
were just upgraded, return
the system to the previous
configuration. If the system
boots without this warning,
then the replaced
component(s) are not
supported with this power
supply. If Energy Smart
power supplies are installed,
replace them with High
Output power supplies to use
the components. See "Power
Supplies."
Install two High Output or
two Energy Smart power
supplies in the system.
You can also run the system
on one power supply until
you can obtain two power
supplies of the same type.
See "Troubleshooting Power
Supplies."
Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines." If
the problem persists, see
"Troubleshooting System
Memory."

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R710 - poweredge - 4 gb ramExternal oemr xl v2 r710

Table of Contents