Troubleshooting A Damaged System - Dell W4X15 Owner's Manual

Table of Contents

Advertisement

Hard drive tray
Cooling shroud
Expansion card risers (if installed)
Expansion cards
Cooling fan assembly (if installed)
Cooling fans
Memory modules
Processor(s) and heat sink(s)
System board
4.
Let the system dry thoroughly for at least 24 hours.
5.
Reinstall the components you removed in step 3 except the expansion cards.
6.
Install the system cover.
7.
Turn on the system and attached peripherals.
If the problem persists, see the Getting help section.
8.
If the system starts properly, turn off the system, and reinstall all the expansion cards that you
removed.
9.
Run the appropriate diagnostic test. For more information, see the Using system diagnostics section.
Next steps
If the tests fail, see the Getting help section.
Related Links
Getting help
Using system diagnostics

Troubleshooting a damaged system

Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Steps
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2.
Remove the system cover.
3.
Ensure that the following components are properly installed:
cooling shroud
expansion card risers (if installed)
expansion cards
power supply unit(s)
cooling fan assembly (if installed)
cooling fans
processor(s) and heat sink(s)
memory modules