6 If not already done, route the interface and RAID battery cables in the
cable path inside the right interior wall of the chassis beneath the cable
retention bracket. See "Cable Routing" and Figure 3-21 through
Figure 3-23.
7 Connect the SAS A cable to the SAS A connector on the backplane and, if
applicable, connect the SAS B cable to the SAS B connector on the
backplane.
8 Close the system. See "Closing the System."
9 Reconnect your system and peripherals to their electrical outlets, and turn
on the system.
Figure 3-21. Storage Controller Card Cabling (2.5-in Hard-Drive Chassis)
1
1
RAID battery (PERC only)
3
SAS A connector on backplane
5
integrated storage controller card
7
SAS_1 connector
114
Installing System Components
2
3
5
4
6
2
SAS B connector on backplane
4
cable retention bracket
6
SAS_0 connector
8
RAID battery connector (PERC only)
7