Table 1-1. LCD Status Messages (continued)
Code
Text
E201A SuperIO
failure.
Power cycle
AC.
E201B Keyboard
Controller
error. Power
cycle AC.
E201C SMI
initializatio
n failure.
Power cycle
AC.
E201D Shutdown test
failure.
Power cycle
AC.
E201E POST memory
test failure.
Check DIMMs.
E2020 CPU
configuration
failure.
Check screen
message.
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
34
About Your System
Cause
SIO failure.
Keyboard controller failure. Remove AC power to the
System management
interrupt (SMI)
initialization failure.
BIOS shutdown test failure. Remove AC power to the
BIOS POST memory test
failure.
Processor configuration
failure.
Incorrect memory
configuration.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
See "Troubleshooting
System Memory."
If the problem persists,
see "Getting Help."
Check screen for specific
error messages. See
"Troubleshooting the
Processor(s)."
Check screen for specific
error messages. See
"Troubleshooting System
Memory".