HDL2500+
series
DC Electronic Load
Quick Guide
2024.06

Advertisement

loading
Need help?

Need help?

Do you have a question about the HDL2500+ Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hantek HDL2500+ Series

  • Page 1 HDL2500+ series DC Electronic Load Quick Guide 2024.06...
  • Page 2: Product Certification

    If you use the documents or products of Qingdao Hantek Electronics Co., Ltd. and need the products, patents or works of a third party to cooperate with it, your company shall be responsible for obtaining the consent and authorization of the third party.
  • Page 3: Safety Requirement

    To reduce the risk of fire and electric shock, ensure that the voltage ⚫ fluctuation of the mains supply does not exceed 10% of the operating voltage range. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 4: Safety Terms And Symbols

    Safety terms in this manual: Danger: Indicates that you may be immediately harmed if you perform this action. Warning: Indicates that you may not be immediately harmed if you perform this action. Note: HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 5: Measurement Category

    For example, measurements are carried out on circuits that are not derived from the mains supply, in particular circuits that are protected (internally) from the mains supply. In the HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 6: Ventilation Requirements

    Poor ventilation can cause the temperature of the instrument to rise, which in turn can cause damage to the instrument. Good ventilation should be maintained during use, and the air vents and fans should be checked regularly. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 7: Working Environment

    Safety requirement 1.5. Working environment The HDL2500+ series electronic loads are only permitted to be used indoors and in low condensation areas, the temperature and humidity described below show the general environmental requirements for this instrument.The fan speed of the HDL2500+ series electronic loads is intelligently adjusted in accordance with the operating status of the machine.
  • Page 8 Example: outdoor environments with shelters. Pollution Degree 4: Permanent conductive pollution through conductive dust, rain or snow. Example: outdoor sites. Security level Class 1 - Grounding Products HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 9: Maintenance And Cleaning

    Before re-energising, please make sure the instrument is dry to avoid electrical short circuit or even personal injury due to moisture. 1.7. Environmental Considerations The following symbols indicate that this product complies with the requirements set out in WEEE Directive 2002/96/EC. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 10 HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 11: Overview Of Documentation

    Overview of documentation 2. Overview of documentation This document is used to guide users to quickly understand the front and rear panels, user interface and basic operation methods of HDL2500+ series electronic loads. Tip: The latest version of this manual can be downloaded at (http://www.hantek.com).
  • Page 12 Trigger key Enter key Menu softkey Document content conventions: The HDL2500+ series of electronic loads contains the following models. If not otherwise specified, this manual uses the HDL2512A++ as an example to illustrate the HDL2500+ series and its basic operation. Model...
  • Page 13 HDL2512H 800V 300W ±(0.025%+0.025%FS)/ USB, ±(0.05%+0.05%FS) RS232,LAN HDL2513A 150V 600W ±(0.025%+0.025%FS)/ USB, ±(0.05%+0.05%FS) RS232,LAN HDL2513B 500V 600W 0.02%+0.025 %FS/0.1 USB, %+0.1%FS RS232,LAN HDL2513C 120V 120A 600W ±(0.025%+0.025%FS)/ USB, ±(0.05%+0.05%FS) RS232,LAN HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 14: General Inspection

    If you find that the appearance of the instrument is broken, the instrument does not work properly, or fails to pass the performance test, please contact the dealer responsible for this business. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 15: Product Presentation

    Product presentation 4. Product presentation HDL2500+ series DC electronic loads cover a wide range of voltage and current, with high accuracy and resolution, to accurately test the performance of the equipment, without missing any details. A variety of test functions, dynamic test and automatic test functions, fully meet the diversified needs of users.
  • Page 16 Enter key: Input confirmation after setting parameters. 7. TFT display 4.3-inch display for system status, input parameters, menu settings, and prompt messages. 8. Restore Default Settings Key Used to restore the instrument state to factory defaults. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 17: Rear Panel Introduction

    AC power to the instrument through this connector. 4. Fuse holder The instrument is shipped with a fuse that meets the standards of the country in which it is used. 5. Digital IO HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 18: User Interface Introduction

    The USB device icon lights up to allow remote control of the electronic load. 5. Network icon display The network icon lights up to indicate that the network is connected and the electronic load can be remotely controlled. 6. Current value HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 19 Pressing the menu key activates the corresponding menu. 9. Power value The power consumed by an electronic load during operation. 10. Voltage value The actual voltage applied to the terminals of an electronic load. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 20: Preparation For Use

    HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 21 Terminal description The HDL2500+ Series load front panel contains the following terminals, and the maximum rated current of the terminal at position (A) is the maximum rated input current of the instrument. All cables are securely secured by manually tightening the terminal.
  • Page 22 Note: When the user does not use the remote measurement function, please disable this function. Test and Sense wires should be as short as possible and Sense wires should be twisted together. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 23: Parameter Setting Method

    After setting the value, click [enter] to save and exit. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 24: Remote Control

    This electronic load can communicate with a PC through the following interfaces: Control via USB ⚫ Control via LAN ⚫ Controlled via RS232 ⚫ Note: Before connecting the communication cable, switch off the instrument to avoid damaging the instrument's communication interface. HDL2500+ Series Quick Guide Copyright © Qingdao Hantek Electronics Co.
  • Page 25: More Product Information

    2、 View option information and option installation For more information on this product, please refer to the relevant brochure (which you can download from the Hantek website (www.hantek.com)). HDL2500+ User's Manual: Provides an introduction to the functions of the ⚫...
  • Page 26 Address:No.780 Baoyuan Road, Gaoxin District, Qingdao, Shandong Province, Building 35, Luandong U Valley Switchboard: 400-036-7077 Email: service@hantek.com Tel: 0532-55678770, 55678772, 55678773 Postcode: 266000 Official website: www.hantek.com Qingdao Hantek Electronics Co.