Hantek HBT3000 Series Quick Manual
Hantek HBT3000 Series Quick Manual

Hantek HBT3000 Series Quick Manual

Internal resistance tester
Hide thumbs Also See for HBT3000 Series:

Advertisement

Quick Links

HBT3000
series
Internal resistance tester
Quick Guide
2023.12

Advertisement

Table of Contents
loading

Summary of Contents for Hantek HBT3000 Series

  • Page 1 HBT3000 series Internal resistance tester Quick Guide 2023.12...
  • Page 2 The copyright of this document belongs to Qingdao Hantek Electronic Co., LTD. Statement Qingdao Hantek Electronic Co., Ltd. reserves the right to amend this document without prior notice. Qingdao Hantek Electronic Co., Ltd. promises that the information provided is correct and reliable but does not guarantee that this document is free from errors.
  • Page 3: Safety Requirement

    Safety requirement Safety requirement Summary of general security issues Read the following safety precautions carefully to avoid injury and to prevent damage to this product or any product connected. To avoid possible dangers, please use this product in accordance with the regulations. Only professionally authorized personnel can perform repairs.
  • Page 4: Measurement Category

    Safety requirement Security terms and signs Security terms in this manual: Warning: Indicates that the operation may not cause immediate damage to you. Warning: Indicates that if you perform this operation, it may not immediately cause damage to you. Note: Indicates that the operation may cause damage to the product or other property.
  • Page 5: Ventilation Requirement

    Safety requirement Class I refers to measurements taken on a circuit not directly connected to ⚫ the main power supply. For example, measurements made on circuits that are not exported from a main power supply, especially from a protected (internal) main power supply. In the latter case, the instantaneous stress will change.
  • Page 6 Safety requirement To avoid the risk of short circuits or electric shock inside the instrument, do not operate the instrument in a damp environment. Altitude Operating and Non-operating: 2,000m. This product is powered by mains conforming to installation (overvoltage) category II. Warning: Ensure that no overvoltage (e.g.
  • Page 7: Environmental Precautions

    Safety requirement Care and Cleaning Care: When storing or placing the internal resistance tester, do not expose the LCD display to direct sunlight for a long time. Cleaning: According to the requirements of operating conditions, regularly check the internal resistance tester and test line. Please clean the outer surface of the instrument according to the following steps:...
  • Page 8 Overview Overview This document is used to guide users to quickly understand the front and rear panels, user interface, and basic operating methods of the HBT3000 series internal resistance tester. Tip: The latest version of this manual can be downloaded at (http://www.hantek.com).
  • Page 9 Overview Model Resistance Voltage Measuring Interface resolution resolution range HBT3561A 0.1μΩ 1μV 0~3.6kΩ/ RS232/485,USB,LAN,I 0~110V O,ANALOG OUTPUT HBT3562A 0.1μΩ 1μV 0~3.6kΩ/ RS232/485,USB,LAN,I 0~210V O,ANALOG OUTPUT HBT3563A 0.1μΩ 1μV 0~3.6kΩ/ RS232/485,USB,LAN,I 0~360V O,ANALOG OUTPUT HBT3564A 0.1μΩ 10μV 0~3.6kΩ/ RS232/485,USB,LAN,I 0~1100V O,ANALOG OUTPUT HBT3565A 0.1μΩ...
  • Page 10: General Inspection

    General inspection General inspection Check transportation packaging After receiving the internal resistance tester, the user should check the equipment according to the following steps: check whether there is any damage caused by transportation: if the packaging carton or foam plastic protective pad is seriously damaged, please keep it until the whole machine and accessories pass the electrical and mechanical tests.
  • Page 11: Product Introduction

    Product Introduction Product Introduction The HBT3000 series internal resistance tester is a battery internal resistance tester with high precision, high resolution, and fast measurement characteristics. Using the AC four terminal testing method to more accurately test the internal resistance and voltage of the battery; 0.1μΩ Resistance resolution, minimum voltage resolution 1μV.
  • Page 12: Introduction To Rear Panel

    Product Introduction Introduction to Rear Panel 1 AC power socket 2 Shell grounding terminal 3 Fuse holder 4 Safety lock holes 5 USB DEVICE interface 6 LAN interface 7 EXT I/O interface 8 ANALOG OUTPUT interface 9 RS-232/485 interface...
  • Page 13: User Interface Introduction

    Product Introduction User Interface Introduction 1 Range Quick Identification 2 Trigger sources 3 Sampling rates 4 Delay 5 USB icon display 6 USB device icon display 7 Network icon display 8 lock screen icons 9 Local/Remote Display 10 Voltage measurement values 11 Resistance measurement value 12 Auxiliary menu bar 13 Resistance range...
  • Page 14: Preparation Before Use

    Preparation before use Preparation before use Connecting the power supply This series of internal resistance testers can input AC power with specifications of 90-240 VAC, 47/63Hz, and 30VA. Please connect the internal resistance tester to the power supply using the power cord provided in the attachment. Press the power switch in the lower left corner of the front panel to turn on the instrument.
  • Page 15 Preparation before use Setting System Language The internal resistance tester supports both Chinese and English menus, and provides corresponding help information, prompt information, and interface display. Press [Utility] ->Other ->English to select the desired language. When selecting "Chinese" or "English", the menu, help information, prompt messages, and interface are displayed in Chinese or English, respectively.
  • Page 16: Using The Built-In Help System

    Using the built-in help system Using the built-in help system To obtain help information for any front panel buttons or menu soft keys, on the measurement display interface, press the [?] button on the front panel, and then press the button you need help with to obtain the operation prompt for that button.
  • Page 17: Set Parameter Values

    Set parameter values Set parameter values The parameter settings of this series of internal resistance testers support numeric keyboard input. Parameter settings can be completed by left clicking, right clicking, and confirmation keys. Move the cursor position by clicking the left and right buttons, and click the confirm button [OK] to input.
  • Page 18: Start Using

    Start using Start using To prevent electric shock accidents, please do not short circuit the top of the ⚫ test line and the line with voltage. Do not measure AC voltage, AC current, or DC current. Otherwise, it may ⚫ cause instrument damage or personal injury accidents.
  • Page 19 Start using Zeroing Click on the [0 ADJ] key, or click on [Utility] ->Cal in sequence. After entering the password, click on the [0 ADJ] soft key to execute zero adjustment. After successful zero adjustment, the interface will pop up as shown in the following figure.
  • Page 20: Remote Control

    Remote Control Remote Control The internal resistance tester can be remotely controlled in the following three methods: 1、User-defined programming: The Standard Commands for Programmable Instruments (SCPI) command can be used to control the internal resistance tester. Please refer to HBT3000-SCPI for detailed instructions on commands and programming.
  • Page 21: Default Value

    Default value Default value The default setting of the machine factory, press the [P] key can restore the instrument state to the factory default value. Function Default value Range Measurement type V&R Voltage range Auto Resistance range Auto Sample Slow Average Trigger Internal...
  • Page 22 Default value Function Default value Buzzer Close Resistance Limit Voltage Limit Utility Brightness GPIB Address Key tone Language Chinese 192.168.1.127 MASK 255.255.255.0 IP MODE Manual Serial-Baud 9600 Serial-Data Serial-Check None Serial-Stop...
  • Page 23: More Product Information

    For more information on this product, please refer to the relevant manual (you can download it from Hantek's official website (www.hantek.com)). HBT3000 Series - User Manual: provides the function of this product to ⚫ introduce the operation method, remote control method, possible faults in the use process and processing methods, and order information.
  • Page 24: Warranty Summary

    During the warranty period, if the product is proven to be defective, Hantek will provide free repair or replacement for the user. Please refer to the official website of Hantek or the product warranty card for detailed warranty regulations.
  • Page 25 地址:山东省青岛市高新区宝源路 780 号,联东 U 谷 35 号楼 总机:400-036-7077 电邮:service@hantek.com 电话:0532-55678770, 55678772, 55678773 邮编:266000 官网:www.hantek.com 青岛汉泰电子有限公司...

This manual is also suitable for:

Hbt3561aHbt3562aHbt3563aHbt3564aHbt3565aHbt3566a

Table of Contents