Download Print this page

ETC High End Systems Zeo User Manual page 28

Advertisement

Error Codes
When you apply power to the fixture, it runs a calibration (homing) sequence and displays any
errors that it detects. The display briefly lists the errors and then shows the main window.
1. Navigate to the Error History menu (Main Menu → Info → Error History) to view a list of
the errors. (Errors are stored in the fixture error history until the errors are cleared from
memory.)
2. Make adjustments, as you are able, to correct the errors (for example, confirm that the
pan and tilt locks are unlocked if Pan Coarse and Tilt Coarse errors are shown).
3. Cycle the power off and on to rehome the fixture:
4. If errors persist after rehoming is complete, contact ETC Technical Services for assistance.
Errors
Pan
This message displays after the reset of the fixture if any of the following conditions exist:
• the yoke's magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
• the stepper motor is defective or the related IC driver on the main PCB has failed
• the Pan movement is not located in the default position after the reset
Tilt
This message displays after the reset of the fixture if any of the following conditions exist:
• the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
• the stepper motor is defective or the related IC driver on the main PCB has failed
• the Tilt movement is not located in the default position after the reset
Zoom
This message displays after the reset of the fixture if any of the following conditions exist:
• the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
• the stepper motor is defective or the related IC driver on the main PCB has failed
• the Zoom wheel is not located in the default position after the reset
24
Zeo User Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the High End Systems Zeo and is the answer not in the manual?

Questions and answers