NOISE OF THE APPLIANCE
The detection was performed at the user's position. The sound pressure level is below 48 [dB(A)] and the continuous sound power level
below 70 [dB(A)].
sound pressure level
sound power level with gas pump in operation
sound power level compressor only
PACKAGING
The device is shipped in a cardboard box protected by an additional cardboard band. The appliance is then further protected inside by a
plastic film bag and expanded polystyrene. When handling the box, always keep the direction of the arrow on the cardboard box
pointing upwards.
CAUTION: When taking the machine out of the box, hold it by the bottom of the base. Do not exert force on the water spout.
The packaging can be removed before taking the machine to the installation site to wait for the technician. The packaging must be
opened from the top. Remove the polystyrene elements and take out the equipment. It is advisable to keep the packaging for future re-
use. Once the packaging has been removed, check that the machine has not been damaged during transport. If this is the case, contact
your dealer. Check the presence of the supplied accessories, which must be contained inside the box. The manufacturer reminds you that
the warranty does not cover damage resulting from transport or unloading and handling. Do not leave packaging materials unattended as
they are potential sources of danger.
WARNING: It is absolutely forbidden to connect the appliance to water sources other than drinking water. Do not use the
appliance to deliver volumes of water greater than those indicated in the technical specifications.
Remember to always keep the CO2 cylinder in an upright position.
DEVICE DESCRIPTION
BWT AQA DRINK OFFICE appliances are drinking water dispensers for direct connection to the water mains, which dispense room-
temperature, chilled and chilled carbonated water. The temperature of the water dispensed can be changed b y adjusting the
thermostat on the back of the device. Prior to installation, the appliance must be kept in an upright position at a room temperature
between 5°C and 40°C and a maximum humidity without condensation of 80%.
POSITIONING
The machine must be located in an indoor environment such as offices, laboratories, waiting rooms, etc., In the vicinity of the machine,
power and water supplies in accordance with the manufacturer's specifications must be available.
A minimum perimeter space of 7 cm must be ensured for sufficient ventilation. For the upper part, maintain a space of 10 cm.
If the appliance has been transported or placed in a non-vertical position, it must be positioned correctly and wait at least 24 hours
before starting it up.
It is forbidden to place the device in the vicinity of direct or indirect heat sources, or on top of other equipment or appliances. Keep
the CO2 cylinder in a vertical position, not exposed to heat sources.
INSTALLATION
After placing the machine in position, it is necessary to proceed with the power supply connection operations.
If the dispenser is placed above a floor and the CO2 cylinder and BWT Bewapur HQ filter (if fitted) are housed underneath it, provide a
suitable hole for the water supply hose (¼ " hose) and the CO2 hose (¼ " hose) to pass through.
The guarantee automatically lapses in the event of:
unauthorised installation or without following the instructions provided;
◼
◼
problems due to power supply faults;
Observe the national regulations in force in the country of installation.
CAUTION: The following work must be carried out by trained and competent personnel. Do not make
temporary connections.
I N S T A L L A T I O N A N D U S E - A Q A D R I N K O F F I C E
48 dB(A)
62 dB(A)
45 dB(A)