Power Supplies

Your system supports the following power supply modules:
717-W High Output power supply
502-W Energy Smart power supply (the default power supply option for
this system)
NOTE:
The system does not support a mixed installation of High Output and Energy
Smart power supplies.
If only one power supply is installed, it must be installed in the PS1 power
supply bay.

Removing a Power Supply

CAUTION:
To ensure proper system cooling, the power supply blank must be
installed in power supply bay PS2 in a non-redundant configuration. See
"Removing the Power Supply Blank."
CAUTION:
If troubleshooting a PSU mismatch error, replace only the power
supply with the flashing indicator. Swapping the opposite power supply to create
a matched pair can result in an error condition and unexpected system shutdown.
To change from a High Output configuration to an Energy Smart configuration or
vice versa, you must power down the system.
1 Disconnect the power cable from the power source and the power supply
you intend to remove and remove the cables from the Velcro strap.
2 Press the lever release latch and slide the power supply out of the chassis.
See Figure 3-7.
NOTE:
it interferes with power-supply removal. For information about the cable
management arm, see the system's rack documentation.
You may have to unlatch and lift the optional cable management arm if
Installing System Components
87