Dell PowerEdge R610 Hardware Owner's Manual page 113

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R610:
Table of Contents

Advertisement

Unlatch the fan assembly and lift it far enough out of the chassis to
c
route the SAS cable along the inside of the chassis, underneath the
plastic retention clip. Replace the fan assembly and close the latches.
See Figure 3-14, "Removing a Cooling Fan," and "Replacing a Cooling
Fan."
Attach the connector labeled "SAS A" to connector SAS A on the
d
backplane, and attach the connector labeled "SAS B" to connector
SAS B on the backplane. See Figure 3-17.
Figure 3-17. Installing the Integrated Storage Controller Card
8
7
6
1
SAS data cable connector
3
back card edge guide (black)
5
front card edge guide (blue)
7
SAS data cable
5 Close the system. See "Closing the System."
1
5
2
3
2
integrated storage controller card
4
expansion card riser 1
6
RAID battery connector (PERC only)
8
cable retention clip
Installing System Components