Dell PowerEdge R610 Hardware Owner's Manual page 34

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R610:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages (continued)
Code
Text
E201B Keyboard
Controller
error. Power
cycle AC.
E201C SMI
initializatio
n failure.
Power cycle
AC.
E201D Shutdown test
failure.
Power cycle
AC.
E201E POST memory
test failure.
Check DIMMs.
E2020 CPU
configuration
failure.
Check screen
message.
E2021 Incorrect
memory
configur-
ation. Review
User Guide.
E2022 General
failure
during POST.
Check screen
message.
34
About Your System
Cause
Keyboard controller failure. Remove AC power to the
System management
interrupt (SMI)
initialization failure.
BIOS shutdown test failure. Remove AC power to the
BIOS POST memory test
failure.
Processor configuration
failure.
Incorrect memory
configuration.
General failure after video. Check screen for specific
Corrective Actions
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
See "Troubleshooting
System Memory."
If the problem persists,
see "Getting Help."
Check screen for specific
error messages. See
"Troubleshooting the
Processors."
Check screen for specific
error messages (see
"Troubleshooting System
Memory").
error messages.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge a03

Table of Contents