Dell PowerEdge R610 Hardware Owner's Manual page 42

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R610:
Table of Contents

Advertisement

Table 1-2. System Messages (continued)
Message
Embedded NIC x and
NIC y :
OS NIC=DISABLED,
Management
Shared NIC=
DISABLED
Embedded NIC x and
NIC y :
OS NIC=DISABLED,
Management
Shared NIC=
ENABLED
Error 8602 -
Auxiliary Device
Failure. Verify
that mouse and
keyboard are
securely
attached to
correct
connectors.
Gate A20 failure Faulty keyboard controller;
General failure
Invalid
configuration
information -
please run SETUP
program.
42
About Your System
Causes
The OS NIC interface is
disabled in BIOS. The
Management Shared NIC
interface is disabled in
management tools.
The OS NIC interface is
disabled in BIOS. The
Management Shared NIC
interface is enabled in
management tools.
Mouse or keyboard cable is
loose or improperly
connected.
Defective mouse or keyboard. Ensure that the mouse or
faulty system board.
The operating system is
unable to carry out the
command.
An invalid system
configuration caused a
system halt.
Corrective Actions
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC."
Check the system
management software or the
System Setup program for
NIC settings. If a problem is
indicated, see
"Troubleshooting a NIC."
Reseat the mouse or
keyboard cable.
keyboard is operational. See
"Troubleshooting a USB
Device."
See "Getting Help."
This message is usually
followed by specific
information. Note the
information, and take the
appropriate action to resolve
the problem.
Run the System Setup
program and review the
current settings. See "Using
the System Setup Program
and UEFI Boot Manager."

Advertisement

Table of Contents
loading

This manual is also suitable for:

Poweredge a03

Table of Contents