Table 1-2. System Messages (continued)
Message
Memory address
line failure at
address , read
value expecting
value
Memory double
word logic
failure at
address , read
value expecting
value
Memory
Initialization
Warning: Memory
size may be
reduced
Memory odd/even
logic failure at
address, read
value expecting
value
Memory set to
minimum
frequency.
Memory tests
terminated by
keystroke.
MEMTEST lane
failure
detected on
44
About Your System
Causes
Faulty or improperly installed
memory modules.
Faulty or improperly installed
memory modules.
Invalid memory
configuration. The system
will run but with less memory
than is physically available.
Faulty or improperly installed
memory modules.
The memory frequency may
be intentionally set lower for
power conservation.
The current memory
configuration may support
only the minimum frequency.
POST memory test was
terminated by pressing the
spacebar.
Invalid memory
configuration. A mismatched
DIMM is installed.
x
Corrective Actions
See "Troubleshooting System
Memory."
See "Troubleshooting System
Memory."
Ensure that the memory
modules are installed in a
valid configuration. See
"System Memory."
See "Troubleshooting System
Memory."
If not an intentional setting,
check any other system
messages for possible causes.
Ensure that your memory
configuration supports the
higher frequency. See
"System Memory."
Information only.
Ensure that the memory
modules are installed in a
valid configuration. See
"System Memory."