Download Print this page

McCrometer Hach Ultra Mag 3000 Quick Start Installation Manual

Battery powered electromagnetic flow meter
Hide thumbs Also See for Hach Ultra Mag 3000:

Advertisement

Quick Links

U
LTRA
WARNING!
!
Incorrect installation or removal of meters
can result in serious injury or death. Read
the instructions in this guide on the proper
procedures carefully.
Any person installing, inspecting, or maintaining
a McCrometer flowmeter should have a working
understanding of piping configurations and systems
under pressure.
Before adjusting or removing any meter, be certain
the system has depressurized completely.
Be careful when lifting meters. Meters can cause
serious injury if lifted incorrectly or dropped.
Hach's Flow Solutions by
M
AG
Electromagnetic Flow Meter
This Quick Start Guide is a supplement to the Installation,
Operation and Maintenance manual supplied with this
meter. It is intended to be a quick reference for the basic
installation and reading of the Ultra Mag 3000.
It is designed to provide installation instructions when the
location of the sensor installation has been predetermined.
Refer to the meter manual (30126-05 Ultra Mag 3000 IOM
manual) for information on these topis:
For information on the data logger, refer to the manual
(30121-87 McLogger IOM), downloadable from www.
mccrometer.com).
About This Quick Start Guide. . . . . . . . . . . . . . . . .1
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
Page 1
Ultra Mag 3000
Battery Powered
Quick Start Installation Guide
About This Quick Start Guide
Preparation and planning for installation
Site location
Software configuration
Detailed information on external connections, external
power, outputs
Check Shipping Crate Contents . . . . . . . . . . .2
Check Serial Numbers . . . . . . . . . . . . . . . . .2
Pipe Run Requirements . . . . . . . . . . . . . . . .2
Sensor Position and Location . . . . . . . . . . . .2
Flow Meter Installation . . . . . . . . . . . . . . . .3
Example Remote Mount Configuration . . . . . .3
Remote Mount Converter Installation . . . . . . .4
Installing Cables through Cable Glands and
Conduit . . . . . . . . . . . . . . . . . . . . . . . . . .4
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . .6
Grounding . . . . . . . . . . . . . . . . . . . . . . . .7
Activating The Display . . . . . . . . . . . . . . . . .8
Converter Boot. . . . . . . . . . . . . . . . . . . . . .8
Converter Configuration . . . . . . . . . . . . . . .9
Error Messages for Troubleshooting . . . . . . . .9
30126-53 Rev. 1.0 | 13SEP2024

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hach Ultra Mag 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for McCrometer Hach Ultra Mag 3000

  • Page 1 • Any person installing, inspecting, or maintaining a McCrometer flowmeter should have a working understanding of piping configurations and systems About This Quick Start Guide....1 under pressure.
  • Page 2 When uncrating the Field Mag, any damage due to Pipe Run Requirements rough or improper handling should be reported to the transportation firm and McCrometer. If for The meter needs to be located a minimum any reason it is determined that the unit or parts...
  • Page 3 LTRA Flow Meter Installation The Field Mag requires grounding to ensure proper functioning and accuracy. See section 9 for grounding instructions and methods. Flanged Meter Installation Install the Ultra Mag flow meter inline between two flanged end pipes. The flow meter may require grounding, depending on the environment they are being installed in.
  • Page 4 Connections to the sensor must be made with and will remove the enclosure’s IP67 rating. Damage cable supplied by McCrometer specifically for that caused by attaching conduit to the enclosure or purpose. Do not substitute the supplied cable with other altering the enclosure in any way is not covered by types of cable, even for short runs.
  • Page 5 LTRA Cable Gland Assignment for Wiring Harnesses Remote Meter Port assignment mount view mount view 1 - Outputs 2 - Outputs 3 - Power 4 - Coils 5 - Electrodes Terminal Block Coils and electrodes Diagram and Grounding Lug Power See next page for wiring diagram for each terminal block.
  • Page 6 Green right. Green • Signals and associated wire colors in the McCrometer SmartOutput™ Black interface cable are identified together in the top row of the table above. Black •...
  • Page 7 LTRA Grounding 1. Preferred method of grounding Grounding ring lug and 12 gauge ground wire Ultra Mag meters come standard with a set of grounding rings for use with the preferred method of grounding Ultra Mag meters. This method can be used for all installations, but it is required for non- conductive or internally coated pipe.
  • Page 8 (POS) or negative (NEG), as shown at right. There is an optical sensor embedded in the display located under the McCrometer “swirl” logo at the lower left. If the display does not appear, a flashlight will provide sufficient light to bring it up. 12345...
  • Page 9 USA Copyright © McCrometer, Inc. All printed material should not be changed or altered McCrometer, Inc. Copyright © 2024 McCrometer, Inc. All printed material should not be changed or altered without without permission of McCrometer. Any published pricing, technical data, and instructions permission of McCrometer.