Page 2
Background Mode....................................8 Window Mode ......................................9 Reset the Sensor to Factory Defaults................................9 Reset Using the Banner Pro Editor Software ..............................9 Reset Using the Remote Input ..................................9 Factory Default Settings via Remote Teach Mode..........................9 Chapter 4 Alternate Modes through Pro Editor..............11 Detection ........................................11...
Page 3
Overview The K50 Pro Select Optical Sensor is an adjustable field optical sensor that can detect a wide variety of materials and objects. Configure the sensor using software or remote input wires to sense objects up to a specific distance, ignoring objects beyond this distance (background suppression), or within a windowed range.
Page 4
K50 Pro Select Optical Sensor Product Manual Features Detection Area Measurement Reference Point Detection not Reliable detection of a stationary and moving object possible Model D0 (mm) Switch Point D1 (mm) Switch Point D2 (mm) K50PSAF1000GRY3Q 1000 Class 1 Laser Description and Safety Information Laser light.
Page 6
K50 Pro Select Optical Sensor Product Manual Chapter Contents Chapter 2 Wiring GRY3 Wiring Diagrams Pinout bn (1) bn (1) – 10-30 V DC 10-30 V DC bu (3) bu (3) – bk (4) bk (4) Load Load wh (2) wh (2) Pin 4 (Black) is Output 1.
Page 7
(0 V DC). The remote input wire is enabled by default. Pulse the remote input wire 7 times or use the Banner Pro Editor software to enable or disable the feature. When the remote input feature is enabled, pulse the remote input according to the diagram and the instructions provided in this manual.
Page 8
Teach Status Color: Blue The K50 Pro Select Optical Sensor is configured to Object Mode by default. Object Mode sets the total Detection Area from the sensor to the Set Point plus the Offset Value (50 mm default). Use Object Mode to trigger a change in state when an object is present between the sensor minimum (20 mm default) and the taught distance plus the offset.
Page 9
Configuring a Sensor K50 Pro Select Optical Sensor Product Manual Detection Area -50 mm (Offset Value) Switch Point (D2) Set Point Window Mode Teach Status Color: Cyan Window Mode centers the total Detection Area at the Set Point plus and minus the Offset Value (50 mm default). Configuring a window near the minimum and maximum ranges shifts this window to ensure that it maintains this value.
Page 11
K50 Pro Select Optical Sensor Product Manual Chapter Contents Detection ..........................................11 Distance ..........................................11 Coarse Distance......................................... 12 Advanced Settings ......................................12 Chapter 4 Alternate Modes through Pro Editor Set sensor parameters for the following applications: • Detection • Distance •...
Page 12
K50 Pro Select Optical Sensor Product Manual Alternate Modes through Pro Editor Distance settings Coarse Distance Divide the Detection Area into custom zones to generate a unique animation when an object is present within that zone distance. Configure up to six zones for animation and output state. The minimum zone distance is 50 mm.
Page 14
K50 Pro Select Optical Sensor Product Manual Chapter Contents FCC Part 15 Class B for Unintentional Radiators .............................. 15 Industry Canada ICES-003(B).................................... 15 Dimensions......................................... 16 Beam Pattern ........................................16 Chapter 5 Specifications Supply Voltage and Current Required Overcurrent Protection 10 V DC to 30 V DC •...
Page 15
Specifications K50 Pro Select Optical Sensor Product Manual Default Indicator Characteristics Color Coordinates Dominant Wavelength (nm) or Color Temperature Lumen Output Per Segment Color (CCT) (Typical at 25 °C) Green 0.154 19.5 0.689 0.309 10.3 Yellow 0.477 0.493 25.8 Blue 0.14...
Page 16
K50 Pro Select Optical Sensor Product Manual Specifications Dimensions All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change. 50.0 mm (1.97") 34.1 mm [1.34"] 50.1 mm [1.97"] 63.1 mm [2.48"] M30 × 1.5 M12 ×...
Page 17
K50 Pro Select Optical Sensor Product Manual Chapter Contents Pro Editor Hardware......................................17 Cordsets ..........................................17 Brackets ..........................................18 Elevated Mount System ..................................... 20 Chapter 6 Accessories Pro Editor Hardware MQDC-506-USB • Pro Converter Cable • 1.83 m (6 ft) length 5-pin M12 quick disconnect to Device and USB to PC • Required for connection to the configuration software ...
Page 18
K50 Pro Select Optical Sensor Product Manual Accessories 5-Pin Single-Ended M12 Female Cordsets Model Length Style Dimensions Pinout (Female) MQDC1-501.5 0.5 m (1.5 ft) MQDC1-503 0.9 m (2.9 ft) 44 Typ. MQDC1-506 2 m (6.5 ft) MQDC1-515 5 m (16.4 ft) Straight M12 x 1 MQDC1-530 9 m (29.5 ft) ø 14.5 MQDC1-560 18 m (59 ft) ...
Page 19
Accessories K50 Pro Select Optical Sensor Product Manual SMBAMS30P • Flat SMBAMS series bracket • 30 mm hole for mounting sensors • Articulation slots for 90°+ rotation • 12-gauge 300 series stainless steel Hole center spacing: A=26.0, A to B=13.0 Hole size: A=26.8 × 7.0, B=ø 6.5, C=ø 31.0 SMBAMS30RA • Right-angle SMBAMS series bracket •...
Page 20
K50 Pro Select Optical Sensor Product Manual Accessories LMBE12RA45 38.25 • Direct mounting of stand-off pipe, with common bracket type • Zinc-plated steel • 1/2-14 NPSM nut • Mounting distance from the wall to the center of the 1/2-14 NPSM nut is 45 mm Hole center spacing: 35.0 2X Ø11 All measurements are listed in millimeters [inches], unless noted otherwise. The measurements provided are subject to change.
Page 21
Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.