Download Print this page

Woodbridge EBT470 Installation And Care Manual

Electronic bidet toilet
Hide thumbs Also See for EBT470:

Advertisement

Available languages

Available languages

Quick Links

INSTALLATION AND CARE GUIDE
ELECTRONIC BIDET TOILET
Compliance with the following codes & standard:
• 2015 Uniform Plumbing Code
• 2018 International Plumbing Code
• 2018 International Residential Code
• CSA B45.5 / IAPMO Z124-2017- Plastic Plumbing Fixtures
SCC Accredited
Accrédité
READ ALL INSTRUCTIONS BEFORE UNPACKING THE PRODUCT
INSTRUCTIONS THAT, IF IGNORED COULD RESULT IN DEATH OR SERIOUS INJURY CAUSED BY INCORRECT HANDLING
OR INSTALLATION OF THE PRODUCT. THESE INSTRUCTIONS MUST BE OBSERVED FOR SAFE INSTALLATION.
We reserves the right to change, update, modify, alter, redesign this manual/product or its policies without prior notice!
We
shall not be liable for any injuries or property damages in connection with this product during installation or use of this product!
This products must be installed by a fully insured and licensed plumber only. Installation of any our product by anyone other
than fully insured and licensed plumber shall void limited warranty. We recommends that such licensed plumber have experience
in the installation of products.
Limited warranty is void on any commercial installation
We are not responsible for local code compliance for this product. Building and plumbing codes may vary from state-to-state in
accordance to your location. We are not responsible for providing any compliance certifications.
Under no circumstances we are shall not be liable for any and all incidental damages sustained in connection with this product
Neither manufacture, nor distributor, nor retailer is responsible for water damage or flood caused due to use of this product.
Under no circumstances We shall not be liable for any and all fees, cost of installation/reinstallation/removal, subsequent
damage or transportation in case of the product defect
®
CB-P/S
ANSI
ACCREDITED
ISO/IEC 17065
OCPS
Product Certification Body
CCN
#1000
2 PEOPLE ARE REQUIRED TO LIFT AND DURING
ENTIRE INSTALLATION OF THIS PRODUCT
INSTALLATION OF THIS PRODUCTS BY AN
INEXPERIENCED INSTALLER MAY RESULT
PERSONAL INJURY OR DEATH!
www.woodbridgebath.com
Model:
( UPC )
( IPC )
®
( IPC )
®
PREFERED
EDUCATION
PROVIDER
EBT470

Advertisement

loading
Need help?

Need help?

Do you have a question about the EBT470 and is the answer not in the manual?

Questions and answers

Summary of Contents for Woodbridge EBT470

  • Page 1 INSTALLATION AND CARE GUIDE ELECTRONIC BIDET TOILET Model: EBT470 Compliance with the following codes & standard: ( UPC ) • 2015 Uniform Plumbing Code ® ( IPC ) • 2018 International Plumbing Code ® ( IPC ) ® • 2018 International Residential Code •...
  • Page 2 Content Safety instructions Technical specification List of materials Dimension/technical data Parts identification Installation of ceramic toilet Previous preparation Auto lid open/close Daily maintenance 1.Main unit care and maintenace 2.Spray nozzle maintenance and care 3.Maintenance of filter net Emergency troubleshooting 1.Electricity and water supply cut-off 2.Failure of remote control 3.When the product is left unused for long time The illustration of Main Unit Keys...
  • Page 3 Safety instructions Please read the instructions carefully before installation and keep it available for future maintenance or reference. Failure to observe this instruction can cause body injury and property damage. Symbol lllustration Indicates that failure to follow the instruction may cause serious Warning injury or a fatal.
  • Page 4 Warning This product should be used with 110V, 50Hz electrical current only, load current is at least 13A. Power plug must be equipped with ground fault circuit interrupter or ground fault electrical leakage protector or similar high sensitive, rapid type leakage switch (Rated sensitive current under 6mA).
  • Page 5 Technical specification Rating pressure 110V,50Hz Rating power 1120W Overall unit IPX4 Waterproof Main Unit Water pressure Minimum water pressure 0.08MPa range Maximum water pressure 0.8MPa Electrical wire length is about 2.2m Average flush 1.28GPF( Full flush 1.6G/Half flush 1.1G) volume Flushing mode Siphonic jet Rough-in...
  • Page 6 Surface 6 different level adjustments temperature Heating power Heated seat Heated burning The seat temperature will automatically decrease to level protection 1 in 10 minutes after using Sensed area,Temperature senor,Thermal fuse, Safety device Bimetal thermostat,Leakage protection plug Night light Intelligent,Often in the off state,Normally on assembly User ID setting To avoid disturbance from remote controls by multi-user...
  • Page 7 List of materials TOILET COMPONENTS During unpacking the product and prior to installation inspect your new product for any damages or missing parts. Do not attempt to install or operate the product if the product is damaged. Installation Manual Remote Control Installation Manual Rough-in Template Components...
  • Page 8 Dimension/technical data Ø3/8" 10" 11-3/8" Rough-in 12" 13-3/4" 22-1/4" Standard 7-1/2" 12-1/4" 19-7/8" 27-5/8" 1.The product drawing is for reference only, and we reserve the right to modify the appearance of the product. 2.If the appearance of the product is changed, the actual product shall prevail. www.woodbridgebath.com...
  • Page 9 Dimension/technical data 27-5/8" 19-1/4" 16" Ø3/8" 1-3/4" 22-1/4" 9-1/2" 2-3/8" 2" 22-1/4" 19-1/4" 2" 3" 12-3/4" 13-3/4" 1.The product drawing is for reference only, and we reserve the right to modify the appearance of the product. 2.If the appearance of the product is changed, the actual product shall prevail. www.woodbridgebath.com...
  • Page 10 Installation Option 19-5/8" 15-3/4" Recommended location for remote control mounting (Left or Right) Angle valve connector Inlet connector Ø3/8" Flexible hose Connect the water inlet and angle valve of the Rough-in 20-7/8" toilet with the matching hose and tighten it 12"...
  • Page 11 Parts identification Bumper Left side Flush Seat Front cleaning button Rear cleaning Porcelain Bowl button Stop/ECO Drying baffle Rear cleaning Front cleaning Power cord Spray nozzle Manual flush button Deodorization window Right side Remote sensing window Touch the sensing area with your foot (optional) www.woodbridgebath.com...
  • Page 12 Toilet Installation 1. Install the matching three-way angle valve 3. Connect flexible hose to water inlet • Mark the center line of the sewage outlet • Connect one end of new hose to water inlet on the ground, and install a three-way and tighten it.
  • Page 13 5. Porcelain toilet installation 7. Connect hose to angle valve Install sealing flange into drain outlet. Connect other end of new hose to angle valve Install ceramic toilet on corresponding and tighten it. position according to contour line. Toilet drain outlet Sealing flange 8.
  • Page 14 Preparation 1. Turn on the angle valve Check thread connection, make sure no leakage is found, unscrew angle valve anticlockwise to maximum opening. (Tips: When opening for the first time, the angle valve handle has a larger torque) Angle valve 2.Power Connection Insert power line leakage protection plug into the power socket, press the reset switch, plug indicator lights on indicating that the power is on.
  • Page 15 Auto open/close lid The intelligent toilet can achieve the function of auto lid open/close. On closed situation, so please function the auto lid open/close function by using remote controller. If the model you purchased is with foot sensor 1. Approaching the toilet 1.
  • Page 16 Daily maintenance Main unit care and maintenace Spray nozzle maintenance and care 1. Nozzle self-cleaning 1. Shut off power supply at maintenance. When no user is seated, press the “Rear Wash/massage” button on the main unit, the nozzle will automatically extend and flow out the washing water.
  • Page 17 Emergency troubleshooting Maintenance of filter net Electricity and water supply cut-off Time for maintenance: It is under 1. No power normal water pressure but poor flush performance occurs. Activate flushing by pressing flush button manually . 1. Unscrew angle valve nut Manual flush button 2.
  • Page 18 When the product is left unused for Failure of remote control long time 1. Operate the panels on Smart bidet seat Especially in winter when no one at home for a long time, please drain out the water inside tank and pipe to prevent freezing. To discharge water 1.
  • Page 19 The illustration of Main Unit Keys The illustration of main unit buttons 1. Press and hold the “Stop” button on the unit, the unit enters the shutdown mode (red light off), press the “stop button” again, the unit returns to the working mode (lights red).[In the shutdown mode, except for the “Stop”...
  • Page 20 Troubleshooting Guide Solution Problem Cause Water inlet hose bent to Solve the problem of bending cause blocking of water inlet hose No water from Inlet valve is off Turn on the inlet valve Nozzle Connect water supply and Water supply is cut off wait for the water Water inlet hose bent to Solve the problem of bending...
  • Page 21 WARRANTY WOODBRIDGE Bathtub, Whirlpool/Air Bubble Massage Tub, Cold Plunge,1 Year limited to be free of defects in material and workmanship. Sauna room and Sauna Tent : 1 Year limited to be free of defects in material and workmanship. Toilet and Bidet : 1 Year limited to be free of defects in material and workmanship.
  • Page 22 IMPORTANT! DO NOT USE: Abrasive cleaners such as: acid, ammonia, bleach, and similar solutions. Use of such solutions may cause corrosion, finish peeling, and/or dull the surface. DO NOT USE: Abrasive sponges or cloth. Never use steel, wool, or wired brushes that will permanently scratch the www.woodbridgebath.com...
  • Page 23 GUIDE D'INSTALLATION ET DE MAINTENANCE BIDET DE TOILETTE ÉLECTRONIQUE Modèle EBT470 Conformité avec les codes et normes suivants: ( UPC ) • 2015 Uniform Plumbing Code ® ( IPC ) • 2018 International Plumbing Code ® • Code résidentiel international 2018 ( IPC ) ®...
  • Page 24 Contenu Instructions de sécurité Spécification technique Liste des matériaux Dimensions/données techniques Identification des pièces Installation de la cuvette céramique Préparation préalable Ouverture/fermeture automatique du couvercle Entretien quotidien 1. Entretien et maintenance de l'unité principale 2. Entretien et maintenance de la buse de pulvérisation 3.
  • Page 25 Instructions de sécurité Veuillez lire attentivement les instructions avant l'installation et conservez-les pour toute maintenance ou référence ultérieure. Le non-respect de ces instructions peut entraîner des blessures corporelles et des dommages matériels. Illustration de symbole Cela indique que le non-respect des instructions peut entraîner des blessures Avertissement graves, voire mortelles.
  • Page 26 Avertissement Ce produit ne doit être utilisé qu'avec un courant électrique de 110V, 50Hz, le courant de charge étant d'au moins 13A. La fiche d'alimentation doit être munie d'un dispositif de protection contre les fuites de courant à la terre, tel qu'un disjoncteur ou un interrupteur de fuite électrique, qui doit être rapide et très sensible(un courant nominal inférieur à...
  • Page 27 Spécification technique Pression nominale 110V,50Hz 1120W Puissance nominale Unité globale IPX4 Unité Imperméable principale Pression d'eau minimale 0.08MPa Plage de pres- sion d'eau Pression d'eau maximale 0.8MPa Longueur d'environ 2.2 m Fil électrique Volume moyen de 1.28GPF( Chasse pleine 1.6G/Demie chasse 1.1G) la chasse d'eau Jet siphonique Mode de rinçage...
  • Page 28 Température de 6 niveaux de réglage différents surface Puissance de chauffage Siège Protection contre La température du siège redescend automatiquement au chauffant les brûlures niveau 1 dans les 10 minutes qui suivent l'utilisation. Zone de détection, capteur de température, fusible Dispositif de thermique, thermostat bimétallique, bouchon de protection sécurité...
  • Page 29 Liste des matériaux COMPOSANTS DES TOILETTES Lors du déballage et avant l'installation, vérifiez le produit pour détecter tout dommage ou pièce manquante. Ne tentez pas d'installer ou d'utiliser le produit s'il est endommagé. Installation Manual Unité de Manuel d'installation Modèle d'ébauche télécommande Tuyau tressé...
  • Page 30 Dimensions/données techniques Ø3/8po 10po 11-3/8po Raccordement 12po standard 13-3/4po 22-1/4po 7-1/2po 12-1/4po 19-7/8po 27-5/8po 1. Le dessin du produit est fourni à titre de référence uniquement, et nous nous réservons le droit de modifier l'apparence du produit. 2. En cas de modification de l'apparence du produit, c'est le produit réel qui prévaut.
  • Page 31 Dimensions/données techniques 27-5/8po 19-1/4po 16po Ø3/8po 1-3/4po 22-1/4po 9-1/2po 2-3/8po 22-1/4po 19-1/4po 12-3/4po 13-3/4po 1. Le dessin du produit est fourni à titre de référence uniquement, et nous nous réservons le droit de modifier l'apparence du produit. 2. En cas de modification de l'apparence du produit, c'est le produit réel qui prévaut.
  • Page 32 Option d'installation 19-5/8po 15-3/4po Emplacement recommandé pour le montage de la télécommande (gauche ou droite) Connecteur de Connecteur d'entrée vanne d'angle Ø3/8po Tuyau flexible Raccordez l'arrivée d'eau et la vanne d'angle Raccorde 20-7/8po des toilettes avec le tuyau correspondant et ment 12po serrez-le.
  • Page 33 Identification des pièces Pare-chocs Côté gauche Couvercle Chasse d'eau Siège Bouton de rinçage avant Bouton de rinçage arrière Cuvette céramique Arrêt/ECO Déflecteur de séchage Rinçage arrière Rinçage avant Cordon Buse de d'alimentation pulvérisation Bouton de rinçage manuel Fenêtre de désodorisation Côté...
  • Page 34 Installation de la cuvette céramique 1. Installation de la vanne d'angle correspondante 3. Raccordez le tuyau flexible à l'arrivée d'eau • Tracez l'axe de la sortie de drainage sur le sol, • Raccordez une extrémité du nouveau tuyau d'eau puis installez la vanne d'angle à l'emplacement et serrez-le.
  • Page 35 5. Installation de la cuvette céramique 7. Raccordez le tuyau à la vanne d'angle • Installez la bride d'étanchéité dans l'orifice de vidange. • Raccordez l'autre extrémité du nouveau tuyau • Installez la cuvette céramique à l'emplacement à la vanne d'angle et le serrer. correspondant à...
  • Page 36 Préparation préalable 1. Ouvrez la vanne d'angle. • Vérifiez le raccord fileté, pour s'assurer qu'il n'y a pas de fuite, dévissez la vanne d'angle dans le sens inverse des aiguilles d'une montre jusqu'à l'ouverture maximale. (Conseils : Lors de la première ouverture, le couple de serrage de la poignée de la vanne d'angle est plus important).
  • Page 37 Couvercle à ouverture/fermeture automatique Les toilettes intelligentes peuvent assurer la fonction d'ouverture/fermeture automatique du couvercle. En cas de fermeture, veuillez utiliser la fonction d'ouverture/fermeture automatique du couvercle à l'aide de la télécommande. Si le modèle que vous avez acheté est équipé d'un capteur de pied 1.
  • Page 38 Entretien quotidien Entretien de l'unité principale Entretien et maintenance de la buse de pulvérisation 1. Coupez l'alimentation électrique lors de l'entretien. 1. Auto-nettoyage de la buse • Lorsqu'aucun utilisateur n'est assis, appuyez sur le bouton "Rinçage/massage arrière" de l'unité principale, la buse se déploie automatiquement et laisse s'écouler l'eau de rinçage.
  • Page 39 Dépannage d'urgence Entretien du filet filtrant Coupure d'électricité et d'eau Temps d'entretien : La pression de l'eau est normale, mais la performance de 1. Pas d'alimentation. rinçage est inefficace. • Appuyez manuellement sur le bouton de rinçage pour activer le rinçage 1.
  • Page 40 Défaillance de la télécommande Lorsque le produit n'est pas utilisé pendant une longue période 1. Actionnez les panneaux du siège de Toilette • En particulier en hiver, en cas de non utilisation intelligent pendant une longue période, veuillez vider l'eau du réservoir et du tuyau afin d'éviter le gel.
  • Page 41 Illustration des touches de l'unité principale Illustration des boutons de l'unité principale 1. Appuyez sur le bouton "Stop" de l'unité et maintenez-le enfoncé, l'unité passe en mode d'arrêt (lumière rouge éteinte), appuyez à nouveau sur le bouton "Stop", l'unité revient en mode de fonctionnement (lumières rouges).[En mode d'arrêt, à l'exception du bouton "Stop"...
  • Page 42 Guide de dépannage è l Solution Le tuyau d'eau est plié et bloqué Résoudre le problème du tuyau d'eau Pas d'eau à la buse Le robinet d'arrivée est fermé Ouvrez le robinet d'arrivée d'eau Branchez l'alimentation en eau et L'alimentation en eau est coupée attendez l'arrivée de l'eau Le tuyau d'eau est plié...
  • Page 43 Cette garantie limitée exclut tout usage industriel, commercial et professionnel. Une preuve d'achat (ticket de caisse original) de l'acheteur original, une description et des photos du défaut, le numéro ou la description du modèle doivent être fournis à Woodbridge Bath pour toute réclamation au titre de la garantie et Woodbridge Bath N'EST PAS responsable des coûts de main-d'œuvre, d'enlèvement ou d'installation.
  • Page 44 Conservez ces instructions d'installation pour référence future! Merci d'utiliser les produits WOODBRIDGE! Si vous avez des questions ou des préoccupations, n'hésitez pas à nous contacter. Téléphone du service à la clientèle: 562-229-0088. (9 h à 17 h, heure normale du Pacifique, du lundi au vendredi) ou par courriel à: help@woodbridgebath.com...