(1). Host panel
(5). Power On/Off button
(2). LCD display
(6). PV switch
(3). Wiring box cover
(7). Battery input port
(4). Wall mounting hole
(8). COM port
1.Before installing the device, check that the package contents are intact and complete against the packing list If any damage is found or any component is
missing, contact your dealer.
2.This guide will be updated from time to time due to product upgrades or other reasons. Unless otherwise agreed this document is intended as a quide only.
All information and suggestions do not constitute an express or implied warranty. The final interpretation of the content is at Growatt's discretion.
3.This document is for quick installation guide only. For details, please refer to the User Manual.
4.Machine damage caused by failure to follow the content is not covered by the warranty.
1. Please make sure that the thickness of the wall for inverter installation is
more than 70mm.
2. Place the mounting template horizontally on the wall, Make sure it is
aligned.
3. Please mark the holes in the 4 mounting holes of hole pattern.
4. Drill a 65 mm deep hole at the marking with a 12 mm drill bit.
SPM 8000-10000TL-HU Quick Guide
(9). PV input port
(10). GRID port
(11). GEN port
(12). LOAD port
SPM 8000-10000TL-HU
457.0/18.00 883.0/34.41
256.0/10.07
5. Please knock the expansion screw rubber sleeve into the hole on the wall,
and then screw on the Expansion screw.
6. Please hang the inverter on the expansion screws, and then tighten the
expansion screws.
NO.
Type
Cable name
Battery input wire
Red and black multi-core copper
AC (Grid, GEN, Load) wire
Two different color stranded wire
PV input wire
Photovoltaic dedicated cable
Grounding wire
Single yellow-green stranded wire
RS485 A+
Min.3-wire shielded twisted pair
Meter communication cable
RS485 B-
Other communication
CAT5E suggested
1.Connect one end of the BMS communication cables to the BMS communication port in the inverter
wiring box.
2.Lead the other end of the BMS communication cables from hole COM2 and connect it to the lithium
battery communication port.
The connection steps are shown on the left.
Note: Only for lithium battery.
3.2 Grid connection, generator connection and load connection
Recommend model
2/0AWG or 4/0AWG
6AWG
Please make sure all switches are OFF before
10AWG
wiring.
12AWG
For personal safety, please do not operate with
electricity.
1.Strip 0.59 inches (15 mm) of the battery cable insulation.
2.Insert the battery cable into the open crimping pliers.
3.Insert the tubular terminal and press the crimping pliers.
4. According to the labels on the terminal blocks(BAT+ BAT-),connect the battery
cable to the corresponding terminal blocks through the circular opening.
5. Use a suitable screwdriver to install the battery cable and tighten the tightening
bolts clockwise.
Note: It is strictly forbidden to connect the positive and negative poles of
the battery input terminals reversely!
1. Connect one end of the temperature sensor cable to the function port(1 red 2 black)
in the wiring box.
2.Take the other end of the temperature sensor cable from hole com1 and attach it to
the lead-acid battery.
The connection steps are shown on the left.
Note: Only for Lead-acid battery.
The AC circuit breaker must be turned off before connecting
the grid, load and generator ports.
1.Strip 0.7inches(18 mm)of the AC cable insulation.
2.Insert the AC cable into the open crimping pliers.
3.Insert the tubular terminal and press the crimping tool.
4. According to the labels on the terminal blocks (Grid - L, N)
(GEN -L,N) (Load - L, N), insert the AC cable directly into the
corresponding terminal block through the circular opening.

Advertisement

loading
Need help?

Need help?

Do you have a question about the SPM 8000-10000TL-HU and is the answer not in the manual?

Questions and answers

Summary of Contents for Growatt SPM 8000-10000TL-HU

  • Page 1 2.This guide will be updated from time to time due to product upgrades or other reasons. Unless otherwise agreed this document is intended as a quide only. All information and suggestions do not constitute an express or implied warranty. The final interpretation of the content is at Growatt's discretion.
  • Page 2 CT is connected to the inverter port correctly. Connect CT to Grid L and make sure that the arrow points from CT to load. The default CT direction is the arrow on the CT pointing from the grid to the machine. Shenzhen Growatt New Energy CO.,LTD The CT direction is settable.