Features
• Industrial Ethernet/Fieldbus serial communication I/O for Smart Factory
• Multiple I/O distribution control using PLCs and industrial PCs.
• Coupler: available in 8 different communication protocols
- EtherCAT, CC-Link V1/V2, ProfiNet, ProfiBus, EtherNet/IP, DeviceNet,
Modbus TCP compatible, Modbus RTU compatible
• Module: various input/output modules, power module
- Bus power + Field power, Bus power/Field power, digital input/output (4/8/16
channels), analog input/output (2/4/8 channels), temperature input (4/8 channels)
- Expandable up to 64 modules (may vary by communication type)
• Hot-swap feature
: Terminal and body units can be removed/swapped during operation for easy
maintenance
• Push-in connection method: easy wire connection without requiring additional tools
• Easy module attachment and removal on DIN rails
• Comprehensive device management software DAQMaster for improved convenience
• Module settings, real-time control/monitoring/diagnosis of input/output signals
• Virtual mode allows simulation of product set up and offers set up recommendations
ᜢ ᜽ ᜨ ᜣ ᜫ
Safety Considerations
• Observe all 'Safety Considerations' for safe and proper operation to avoid hazards.
• ᜸ symbol indicates caution due to special circumstances in which hazards may occur.
᜸ Warning
Failure to follow instructions may result in serious injury or death.
01. Fail-safe device must be installed when using the unit with machinery that
may cause serious injury or substantial economic loss. (e.g., nuclear power
control, medical equipment, ships, vehicles, railways, aircraft, combustion
apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire or economic loss.
02. Do not use the unit in the place where flammable/explosive/corrosive gas,
high humidity, direct sunlight, radiant heat, vibration, impact, or salinity
may be present.
Failure to follow this instruction may result in explosion or fire.
03. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
04. Do not connect, repair, or inspect the unit while connected to a power
source.
Failure to follow this instruction may result in fire.
05. Check 'Connections' before wiring.
Failure to follow this instruction may result in fire.
᜸ Caution
Failure to follow instructions may result in injury or product damage.
01. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or shortening the life cycle of the
product.
02. Use dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire or electric shock.
03. When connecting the power input and output, use AWG 22-16 cable and
check the connecting method of crimp terminal.
Failure to follow this instruction may result in fire or malfunction due to contact
failure.
04. Keep the product away from metal chip, dust, and wire residue which flow
into the unit.
Failure to follow this instruction may result in fire or product damage.
05. Do not connect or disconnect connector (terminal) wire or power, when the
product is operating.
Failure to follow this instruction may result in fire or malfunction of the product.
Cautions during Use
• Follow instructions in 'Cautions during Use' .
Otherwise, It may cause unexpected accidents.
• BUS power and I/O power should be insulated by the individually insulated power
device.
• Power supply should be insulated and limited voltage/current or Class 2, SELV power
supply device.
• Keep away from high voltage lines or power lines to prevent inductive noise.
In case of installing power line and input signal line closely, use line filter or varistor at
power line and shielded wire at input signal line. For stable operation, use shield wire
and ferrite core, when wiring communication wire, power wire, or signal wire.
• Do not use near the equipment which generates strong magnetic force or high
frequency noise.
• Use the rated standard cables and connectors. Do not apply excessive power when
connecting or disconnecting the connectors of the product.
• Do not touch the module communication connector part of the base.
• Do not connect, or remove the base while connected to a power source.
For removing the terminal, body or base, do not operate units for a long time without it.
• This unit may be used in the following environments.
- Indoors (in the environment condition rated in 'Specifications')
- Altitude max. 2,000 m
- Pollution degree 2
- Installation category II

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ARIO Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Autonics ARIO Series

  • Page 1 For your safety, read and follow the considerations written in the instruction power line and shielded wire at input signal line. For stable operation, use shield wire manual, other manuals and Autonics website. and ferrite core, when wiring communication wire, power wire, or signal wire.
  • Page 2: Definitions Of Terms

    AO: Analog output RTD: Resistance thermometer Body ❹ Number of channels 02: 2 channels A component of the ARIO series designed for the function control and management 04: 4 channels in modules. 08: 8 channels Base 16: 16 channels A component of the ARIO series designed for conveying power and communication line ■...
  • Page 3: Sold Separately

    Module Terminal model Body model Base model considerations and/or detailed precautions in the manuals. ARIO-TERMINAL-12 ARIO-BASE-S ARIO-S-DO04P ARIO-BODY-S-DO04P Download the manuals and the installation software from the Autonics website. ARIO-S-DO04N ARIO-BODY-S-DO04N ARIO-S-DO08P ARIO-BODY-S-DO08P Reference manuals Descriptions ARIO-S-DO08N ARIO-BODY-S-DO08N Product manual It contains information for you to setup and install the ARIO Unit.
  • Page 4: Unit Descriptions

    -|Transparent Guide|- Check the Version Compatibility Unit Descriptions Before using the product, be sure to verify the compatibility of the coupler and modules. For detailed information about each coupler and module, refer to the respective Refer to the software (SW) and functional version (SU) indicated on the nameplate at manuals of the couplers and modules.
  • Page 5: Power Supply And Distribution

    -|Transparent Guide|- Power Supply and Distribution ■ The configuration of ARIO unit • The ARIO unit is designed to be mounted on a DIN rail. Therefore, adhere to the Field Power Module Bus Power Module recommended distances and directions during installation. • When configuring the ARIO unit, install the coupler on the far left first, and then install the modules to the right of the coupler in sequence.
  • Page 6: Wiring Requirements

    -|Transparent Guide|- Wiring Requirements ■ Ferrule terminal specifications • Be sure to use the UL-approved ferrule terminals. 01. Use the wires made of copper conductors with a temperature • For the temperature input modules: Be sure to use wiring and ferrule terminals rating of 60 °C.
  • Page 7: Installing On A Din Rail

    -|Transparent Guide|- Installing on a DIN rail Maintenance ■ Hot-swap The installation of the ARIO unit on a DIN rail starts from the left side, based on the horizontal orientation. The hot-swap function allows the replacement of terminal and body parts of a module •...
  • Page 8 -|Transparent Guide|- Specifications: Couplers Specifications: Digital Input/Output Modules ■ General specifications ■ General specifications Protection circuit Reverse field and supply power protection circuit Transmission speed 4 Mbps (ABUS) - ARIO unit: ≤ 9.6 W, ≤ 400 mA (≤ 200 mA/CH, 2-CH/COM) Power supply - Field: ≤...
  • Page 9 -|Transparent Guide|- Specifications: Analog Input/Output Modules ■ Analog output modules ■ General specifications Model ARIO-S-AO□V1 ARIO-S-AO□V2 Output specifications Voltage output Transmission speed 4 Mbps Channels 2-CH / 4-CH (ABUS) Data size 4-byte / 8-byte Protection circuit It depends on the module type. Output range ±10 VDCᜡ...
  • Page 10 -|Transparent Guide|- Specifications: Temperature Input Modules Specifications: Power Modules ■ General specifications ■ General specifications Transmission speed Transmission speed 4 Mbps 4 Mbps (ABUS) (ABUS) Protection circuit Reverse field power protection circuit Reverse bus power protection circuit, Protection circuit Bus power short circuit protection circuit I/O to internal circuit: photocoupler insulated / Insulation Between channels: non-insulated...
  • Page 11 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation) Protection rating IP20 (IEC standard) Specifications: Certifications ᜢ ᜽ ᜨ ᜣ ᜫ Certification ᜺ ᜹ ᜼ ᜻ 01) The EAC certification differs by model. 18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002 www.autonics.com | +82-2-2048-1577 | sales@autonics.com...

Table of Contents