Cleaning The Platen Roller - Datamax I-4206 Operator's Manual

Thermal transfer printer
Hide thumbs Also See for I-4206:
Table of Contents

Advertisement

5.3.2

Cleaning the Platen Roller

A platen roller contaminated with grit, label adhesive, or ink can cause a decline
in print quality and, in extreme cases, cause labels to stick and wrap around the
roller. To clean the platen roller:
Turn 'Off' and unplug the printer.
Open the access cover. Unlock the Printhead Latch and raise the Printhead
Assembly. Remove media and ribbon.
Using a Cotton Swab dampened with isopropyl alcohol, clean the Platen
Roller; manually rotate the roller and repeat, cleaning the entire surface.
Allow the Platen Roller to dry.
Replace ribbon and media.
Lower the Printhead Assembly and rotate the Printhead Latch completely
back, to the locked position.
Close the access cover. Plug in and turn 'On' the printer. Feed several labels
to normalize tracking.
NEVER use a sharp object to clean the Platen Roller.
CAUTION